LSD linear sectored slot diffusers

Documentos relacionados
LNG linear slot diffusers

MADEL. LNG difusores lineales

MADEL. DIMO difusores modulares de núcleo decorativo MADEL

DCN DIFUSORES CIRCULARES

kli kl n RXO d ifusores difusores rotacionales de a letas aletas fijas fijas M A D E L RXO RXO M d o elos: RXO-S RXO-KLIN RXO-C

MADEL. NEX difusores rotacionales de elementos cóncavos MADEL

DCN DIFUSORES CIRCULARES

DCG difusores circulares de conos regulables

DCG difusores circulares de conos regulables

AXO difusores rotacionales de aletas orientables

PLAY DIFUSORES DE MÓDULOS ORIENTABLES

DFZ Difusores de placa perforada

AX6 difusores rotacionales de aletas regulables

Type KUL. Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation

MAD E L. KAM Toberas de largo alcance. Diftronic

MADEL. DMT rejillas para retorno de aletas fijas a 45º. klin SYSTEM

MADEL. RMT rejillas para retorno de retícula. klin SYSTEM

MADEL. DMT rejillas para retorno de aletas fijas a 45º. klin SYSTEM

kli kl n RXO d ifusors difusors rotacionals rotacionals d' d aletes aletes fixes M A D E L RXO RXO M d o els: RXO-S RXO-KLIN RXO-C

Type WGK WITH SMALL BLADE PITCH

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ. Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings in walls and ceiling slabs

Type WG FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

AXO difusors rotacionals d'aletes daletes orientables

DIFUSORES LINEALES Diffuseurs linéaire à fentes SLOT DIFFUSER Difusores Lineares

Sistemas para puertas correderas de madera SLID

BON JOUR PRIVATE HOUSE - THE NETHERLANDS

FUSIBLES DE CUCHILLA NH gg 690 V CON PERCUTOR NH KNIFE TYPE gg 690V FUSE-LINKS WITH STRIKER

serie DID-R PÁGINA PRINCIPAL > Productos > Sistemas aire - agua > Vigas frías activas > Unidad de Inducción para instalación en techo > Type DID-R

ACABADO CUERPO ACABADO PALAS TR MATERIAL PALAS LED 15W /BODY FINISH /BLADE FINISH /BLADE MATERIAL 1450LÚMENES

CAJAS DE TRANSMISIÓN DE SIMPLE ASPIRACIÓN Serie UPE-SA

5SISTEMAS MODULARES MODULAR SYSTEMS

Líneas de madera maciza en techos y paramentos Lines of solid wood in ceilings and walls

O2 ARENA STADIUM - U.K.

Regleta industrial Industrial gear tray

Proyectores P AU

Techo T RA 7044

FUSIBLES DE CUCHILLA NH gg 690 V (Ind. Sup.) NH KNIFE TYPE gg 690V FUSE-LINKS (top Indic.)

Soler & Palau C/DAB. Todos los derechos reservados MR. 2001

Ventiladores de tejado. F400 centrifugal fan, ABS cowl Ventilador de tejado, sombrero ABS

FUSIBLES DE CUCHILLA NH gg 500 V NH KNIFE TYPE gg 500V FUSE-LINKS

Arne. Santa & Cole Team 2013

Luminarias polivalentes Recessed luminaires

Proyectores P BL

PUERTA SLIM SLIM DOOR

SAKMA SPECIALIST IN LED TECHNOLOGY LSK 50E. Lineal empotrable para techos Armstrong Recessed linear lighting for Armstrong ceilings 0-10V

Apliques. A NE Up & Down

TYCO SBP. design Arch. Silvia Paola Pennacchio

SAKMA SPECIALIST IN LED TECHNOLOGY VESTA OPTICS. Iluminación industrial de altas prestaciones High performance industrial lighting 0-10V

Empotrados E RA 6011

Blok Line. 100mm. 130mm

STUA SAPPORO JESUS GASCA 1998

XXX Sliding doors with soft closing system LITE GLASS+ Interior Design Glass Interiorismo Vidrio

Proyectores. P Cu

KAP DESIGNED BY FLOS ARCHITECTURAL K A P Ø105 K A P S Q U A R E. PHOSPHOR LED 13W 1000 lm 3000K CRI 80 QR-CBC 51 GX5.

Enric Batlle, Joan Roig 2007

Cajas acústicas serie UPA Direct-drive low pressure centrifugal acoustic UPAinet fans UPA series

Luminaria empotrable para techo de perfil visto T-bar ceilings luminaire

Suspensión S NE

Ventilador industrial de 3 palas en acabado niquel sin luz. Ideal para decoración en hostelería. Se regula mediante control de pared.

DECLARACION DE CONFORMIDAD DECLARATION OF CONFORMITY

With temperature switch Cover for protection against high surface temperatures

n Protection class: IP68 IS/IEC 60529:2001 DIN EN6059 n Screws material: Stainless steel. n High shock resistance. n Wall thickness: 4 mm-5 mm.

Series 5.7. Series 5.7. Sizes Tamaños: 05 / 11 / 16 / 23 / 50 / 10 / 13 / 18 / 36

Tirador 3 vías, 5 vías y Palanca 2 vías 3 ways puller, 5 ways and 2 ways lever

Datasheet DOWNITO 70 DEEP ADJUSTABLE (+/- 30 ) 20/02/17 Grupo MCI

stair profiles & aisle profiles

Iluminación General. Gama profesional de alto rendimiento. Professional range of high performance. 12W. CRI(Ra) >80 50/60 50/60 64 YLD S.A.

XXX Sliding doors with soft closing system LITE+ Wooden-Metal sliding door Puerta Corredera de madera-metal

ROLL GLASS ROLL GLASS 40/ ROLL GLASS 90 ROLL GLASS 135/ ROLL GLASS 175

TR Down. Josep Ll. Xuclà

DIFUSORES Diffuseurs DIFFUSERS Difusores

Descripción / Description. Imagen / Image

TR Spot&Up. Josep Ll. Xuclà

TR Spot&Up. Josep Ll. Xuclà

Lacado negro mate Matt black lacquering (RAL 9005) Lacado visón Mink lacquering (NCS S 2005-Y10R)

Apliques A NE

Cilindros con cerrojo Cam locks

TELESCOPIC FRAMELESS GLASS DOOR SYSTEMS SISTEMAS PARA PUERTAS TELESCÓPICAS DE VIDRIO SIN MARCO EXTENDO

Architecture on the ceiling Design by Ramón Esteve. Arquitectura en el techo Design by Ramón Esteve

Batiflex 3000 Puertas batientes / Flexible doors BISAGRAS DE VAIVEN: Fabricadas totalmente en duralinox anodizado plata en 0 micras. Provista de regul

ACABADO DE ARANDELA RING FINISH

ACABADO DE ARANDELA RING FINISH

FUSIBLES DE CUCHILLA NH am (Ind. Sup.) NH KNIFE TYPE am FUSE-LINKS (top Indicator)

Túnel plegable de Aluminio

13 vitrinas 15/10/09 13:33 Página 1 13 VITRINAS SHOWCASES

Focus Line IP44. J. M. Wilmotte

Art Caja Final Carrera con microelectromecánico. Art Caja Final Carrera con Detector Inductivo

NOZZLE SAKMA SPECIALIST IN LED TECHNOLOGY. Downlight orientable y ligero de alta calidad Adjustable and lightweight high quality downlight 0-10V

Art Caja Final Carrera con Detector Inductivo

C17B. 34cm / 13 ¼. ø 17cm / 6 ¾. ø 12,8cm / 5. 23cm / 9 máx. 200cm / 78. ø 17cm / 6 ¾. ø 40cm / 15 ½ Merlot (matte) Limeston (matte) Grey (matte)

ACCESORIOS PARA PUERTAS

Campanas C BL PL

Apliques A BL

Datasheet SMOOTH /07/18 Grupo MCI

FICHA TÉCNICA / DATA SHEET DOWNLIGHT LED LEDION MINI 25W. Ref.: 3001 DESCRIPCIÓN / DESCRIPTION INSTALACIÓN / INSTALLATION INCLUYE / INCLUDES

OPTIONS. Conexión - Connection : Triángulo - Delta Y: Estrella - Star. Posición - Position Nº Modelo - Model Nr.

Electrobombas centrífugas monobloc horizontal Serie NORMALIZADA a 1450 y 2950 r.p.m.

Transcripción:

linear sectored slot diffusers M ADEL The series linear diffusers are designed to combine the aesthetics with the technical performance. They can be mounted in false ceilings or suspended from the ceiling. They allow the formation of diffuser continuous lines, with active and inactive areas, without breaking the uniformity of the whole. They are suitable both for supply and return. By adjusting their blades, sectored each mm, it is possible to obtain a horizontal distribution of the air in one or the other direction or its vertical projection without change the volume of air. The diffusers admit a flow variation of % keeping the air stream stable. These diffusers can be used from, up to metres high and at a temperature differential up to º C. /

-AR A C B 9, E CLASSIFICATION -AR Diffuser with end borders included. Suitable for lengths m. -ARI Diffuser with an end border on the left side, required to form lines >m. -ARD Diffuser with an end border on the right side, required to form lines >m. -INT Diffuser without end borders, required to form lines > m. NºVIAS E A B C 7 7 9 7 9 7 9 G N MATERIAL Diffuser constructed from aluminium and deflection vanes from PVC in black colour. L M=L+ L M N G 7 7 7 7 7 -ARI -ARD -INT /

A9/ E A ADDITIONAL ACCESSORIES A9/ Inactive diffuser without end borders, making a 9º angle. NºVIAS E A P Plenum box with lateral circular connection. It includes supports to hang from the ceiling. Made in galvanised steel. -R Plenum box with a flow damper in the spigot. /AIS/ Plenum box thermo acoustically insulated by a foam with a coefficient of 7 97 7 7 7 -AR + P -R N thermal conductivity of, w/mk. This foam complies with the fire reaction specifications: UNE -77 M NFP 9- M DIN M D N 9 7 E 7 7 E L' = L- H M = L+ L <. L < L <, L <, L < H D H D H D H D H D / / 9 /9 9 /9 / / 9 /9 9 /9 / / 9 /9 9 /9 / / 9 /9 9 /9 / / 9 /9 9 /9 /

D P PM FIXING SYSTEMS (D) Support brackets to hang or +P from the ceiling. (PL) Connection into P+PML plenum box by screws, to hang from the ceiling. This system simplifies and facilitates the assembly and disassembling of the diffuser into the plenum box. (PM) Set of crossbars for installation of the diffuser without plenum in false ceiling. FINISHES AA Matt silver anodised. M9 Painted in white similar to RAL 9. R9 Painted in white RAL 9. RAL... Painted in other RAL colours. (PL) SPECIFICATION TEXT Supply and mounting of linear slot diffuser with sectored adjustable vanes series -AR+P-R AA x constructed from aluminium and anodised in matt silver AA. With lateral circular connection plenum box and air flow damper in the spigot P-R. Manufacturer MADEL. /

VELOCIDAD RECOMENDADAS. VIAS Vmin Vmax...... SECCION LIBRE DE SALIDA DEL AIRE (m).. m m. m m..7..7.7.7.....9..7...9 VALORES DE CORRECCION PARA DPt Y Lwa. -AR + PLDS-R Dpt Lwa Dpt Lwa Dpt Lwa Dpt Lwa.9.. - - -,.9.. - -, -,.9.. -7 - -.9.. -, -, -, ALCANCE KL. m m. m m % % % % % % % % % % % % DPt = Kp x DPt Lwa = Lwa + Kf A.......,, +, +,9 +, - - -,......7. +, +, +, +, +, + +,.. +,9 +, -,7 -, -,7 -, -, -,... m m. m m.7.7..7.9..7...7.. AL` = Kl x AL B.......... +, +, -, -, -, -,7 - -, B C H AL. (m)....... AL. (m) Afree (m). VELOCIDAD LIBRE, PERDIDA DE CARGA Y POTENCIA SONORA, ALCANCE CON EFECTO TECHO: DIRECCIÓN. -AR + P Vf. 7 9.,,,,7,,,,,,,,,,,9,,,,,7,,, DPt (Pa), 7. 9.. 7.. AL. (m) VIAS VIAS VIAS VIAS VIAS VIAS VIA VIA 7 7 LWa = ( db(a)) Q (m/h) 7 7 AL. = A AL.= B+H AL.= C+H,.. 7 9 Vf Nota: En MadelMedia Espectro por banda de octava en Hz. /

FACTOR DE CORRECCION DE LA DIFUSIÓN VERTICAL (bv) PARA DT (-). Dt( C) - - ALCANCE (L.) DT (-). Dt( C) - -......7.. Kh.9.9.. Kl.7 Kh = Factor de corrección de l a difusión vertical. kl = Factor de corrección del alcance. AL. bv bv = Kh x Al AL. ( Dt < ) = Kl x AL.. RELACION DE TEMPERATURAS. RELACION DE INDUCCION. Dtl = Dtz t local - t x t local - t imp i = Qr Q = Q total en x Q de impulsion..... 9 7 VIA VIAS VIAS VIAS..9..7.... AL. (m) 7 VIAS VIAS VIAS VIA 9.. 7 9 AL. (m) /

VELOCIDAD RECOMENDADAS. VIAS Vmin Vmax... SECCION LIBRE DE SALIDA DEL AIRE (m).. m m. m m..7..7.7.7.....9..7...9 Afree (m)..,,,,7,,,,,,,,,, VALORES DE CORRECCION PARA DPt Y Lwa.,,7. m m. m m, % % % % % % % % % % % % Dpt.9........7., Lwa -,9 -, - +, +, +, +, +, -, +,9 +,, Dpt.9......... Lwa -, -, -, +, +, -, -, -, -, -, -, 7 DPt = Kp x DPt Lwa = Lwa + Kf ALCANCE KL A. m m. m m,.7..77..7 AL` = Kl x AL B B C AL. (m)...... AL. (m).,9,, DPt (Pa)....,, AL. (m) VELOCIDAD LIBRE, PERDIDA DE CARGA Y POTENCIA SONORA, ALCANCE CON EFECTO TECHO: DIRECCIONES. 9 7 VIAS VIAS Vf 7 9 7 7 LWa = ( db(a)) Q (m/h) 7 7 H.. VIAS VIAS AL. = A AL.= B+H AL.= C+H,.. 7 9 Vf Nota: En MadelMedia Espectro por banda de octava en Hz. 7 /

FACTOR DE CORRECCION DE LA DIFUSIÓN VERTICAL (bv) PARA DT (-). ALCANCE (L.) DT (-). - Dt ( C) - Dt ( C) - -......7. Kh..9.9. Kl..7 Kh = Factor de corrección de l a difusión vertical. kl = Factor de corrección del alcance. AL. bv = Kh x Al. bv AL ( Dt < ) = Kl x AL.. RELACION DE TEMPERATURAS. RELACION DE INDUCCION. Dtl = t local - t x i Qr Q total en x = = Dtz t local - t imp Q de impulsion Q..... 9 7 VIAS VIAS..9..7.... AL. (m) 7 9 VIAS VIAS.. AL. (m) 7 9 /

VELOCIDAD RECOMENDADAS. VIAS Vmin Vmax...... SECCION LIBRE DE SALIDA DEL AIRE (m)..7...9 Afree (m)..,,,,7,,,,,,,,,,,. m m. m m % % % % % % % % % % % %, Dpt.9.........,7 Lwa - - -,7 +, +, + +,7 +, -, -, -,9, Dpt.9........7. Lwa -,7 -, -,9 +, +, +, +, +, -, +, +,9, Dpt.9........., Lwa -,9 -, -,9 +.9 +, - -,9 - -, -, -, Dpt.9.... - -,9 -... Lwa -, -, -, +, +, - -, -, - -, -, 7 DPt = Kp x DPt Lwa = Lwa + Kf ALCANCE KL. m m. m m..7..7.7.7.....9. VALORES DE CORRECCION PARA DPt Y Lwa.,9,,, DPt (Pa) VELOCIDAD LIBRE, PERDIDA DE CARGA Y POTENCIA SONORA, ALCANCE CON EFECTO TECHO: DIRECCIONES. 7 Vf 7 LWa = ( db(a)) Q (m/h) 7 7 9. m m. m m....7.7...7..9..9 AL. (m)........ AL. (m) AL. (m) 9 7 VIAS VIAS VIAS VIA 7 AL` = Kl x AL... A B B C.. H AL. = A AL.= B+H AL.= C+H,.. VIAS VIAS VIAS VIA Vf 7 9 Nota: En MadelMedia Espectro por banda de octava en Hz. 9 /

FACTOR DE CORRECCION DE LA DIFUSIÓN VERTICAL (bv) PARA DT (-). Dt( C) - - ALCANCE (L.) DT (-). Dt( C) - -......7.. Kh.9.9. Kl..7 Kh = Factor de corrección de l a difusión vertical. kl = Factor de corrección del alcance. AL. bv = Kh x Al. bv AL ( Dt < ) = Kl x AL.. RELACION DE TEMPERATURAS. RELACION DE INDUCCION. Dtl = Dtz t local - t x t local - t imp i Qr = = Q Q total en x Q de impulsion..... VIAS VIAS VIAS 9 7 VIA VIAS VIAS VIAS. VIA..... 7 9 AL. (m).. 7 9 AL. (m) /

VELOCIDAD RECOMENDADAS. VIAS Vmin Vmax...... SECCION LIBRE DE SALIDA DEL AIRE (m)..7...9 Afree (m),,,7,,,,,,,,,, VELOCIDAD LIBRE, PERDIDA DE CARGA Y POTENCIA SONORA: IMPULSION VERTICAL..., % % % % % % % % % % % %, Dpt.9.........,7 Lwa -, -, -, +, +, +,9 +, + -, -, -,9 Dpt.9........7., Lwa -, -, -,9 +, +, +, +, +, -, +,9 +,, Dpt.9......... Lwa -7 -, - +,9 +, -, -, -,9 -, -, -,, Dpt.9......... Lwa -, -, -, +, +, -,9 -, -, -,9 -, -, 7 ALCANCE KL. m m. m m..7..7.7.7.....9. VALORES DE CORRECCION PARA DPt Y Lwa.. m m. m m DPt = Kp x DPt Lwa = Lwa + Kf,9,,, DPt (Pa), 7 7 Vf LWa = ( db(a)) Q (m/h) 7 7 9. m m. m m.7...7...7...7.. ALv '. = Kl x ALv AL. (m)......... AL. (m). AL. (m) 9 7 VIAS VIAS VIAS VIA 7.. Alv. H.... VIAS VIAS VIAS VIA 7 9 Vf Nota: En MadelMedia Espectro por banda de octava en Hz. /

ALCANCE VERTICAL (Alv,) DT(+). EJEMPLO: D T(+) DT(+) DT = T impulsión - T ocal. VIAS x m VIA.7. Afree =. m. VIAS.7. Vf =. m/s. ALv, =.9 m. VIAS.77. ALv =. x.9 =.9 m. VIAS.. Alv, (DT +) = Kv x Al DT(+) =.7 x.9 =. m. DT (+) =. x.9 =.7m. VELOCIDAD LIBRE, PERDIDA DE CARGA Y POTENCIA SONORA. VELOCIDAD RECOMENDADAS. VIAS SECCION LIBRE DE SALIDA DEL AIRE (m). Vmin Vmax... m m. m m..7..7.7.7.....9..7...9 VALORES DE CORRECCION PARA DPt Y Lwa.. m m. m m % % % % % % % % % % % % Dpt.. Lwa - Dpt... Lwa - Dpt... Lwa - Dpt.7.. Lwa -.. - 7.. - 7.. -.. - DPt = Kp x DPt Lwa = Lwa + Kf..7...9.7 Afree(m) - - 7..9.7...9-7... -..7. - -..7. -..9. -..,,,,7,,,,,,,,,,,9,,,,,,7,, DPt (Pa), 7 Vf 7 VIAS VIAS 7 VIAS VIA 7 LWa = ( db(a)) Q (m/h) 7 9 7 9 Vf /