NUEVOS SERVIDORES IBM M4
|
|
- María Soledad Henríquez Duarte
- hace 8 años
- Vistas:
Transcripción
1 NUEVOS SERVIDORES IBM M4
2 On March 6, we introduced our new best-selling servers System x3650 M4 System x3550 M4 Adalio Sanchez announcing the new portfolio at CeBIT Server Features Slotless, multi-vendor flexible networking Integrated RAID card exflash High IOPS storage Significant performance boost Feature on Demand New management module Fast boot time & remote presence High efficiency thermal and power design System x3500 M4 idataplex dx360 M4 BladeCenter HS23
3 Intel Xeon Server Roadmap Expandable (EX) Dunnington (6C / 6T) Caneland Platform Nehalem-EX (8C / 16T) Boxboro-EX Platform Westmere-EX (10C / 20T) Sandy Bridge EP4S (8C/16T) TBD 0 Ivy Bridge-EX-A 0 (TBD) Brickland-EX Platform Ivy Bridge EP4S TBD Romley-EP4S Platform 2S Server (Performance) Nehalem-EP (4C / 8T) Tylersburg-EP Platform Westmere-EP (6C / 12T) Sandy Bridge -EP Skt R (8C/16T) Romley-EP Platform Ivy Bridge-EP Skt R (TBD) 2S Server (Entry) Sandy Bridge-EN Skt B2 (8C/16T) Romley-EN Platform Ivy Bridge -EN Skt B2 (TBD) 1S Server Lynnfield Processor Clarkdale Foxhollow Platform Sandy Bridge Skt H2 (4C/8T) Bromolow Platform Ivy Bridge Skt H2 (TBD) Carlow Platform In planning
4 Mejore e su negocio con los nuevos servidores M4 Servidores 1 y 2 procesadores ejecutan el 75% cargas de trabajo Implementar rapidamente cargas de trabajo forma rápida y sencilla Infraestructura escalable con servidores virtualizados, recursos de red y soluciones flexibles Tecnologías punteras desarrolladas para sistemas high-end implantadas en soluciones bajo coste. Mejorar sus niveles de servicio maximizando su rendimiento en plataformas fiables y seguras Reducir Coste Total de Propiedad con soluciones infraestructura de alto rendimiento y eficiencia Reducir complejidad datos con soluciones probadas IBM IBM Corporation
5 Soluciones críticas de negocio: Aumento Rendimiento Soportar más cargas de trabajo en un servidor o mayor rapidez en la ejecución #1 OLTP +45% #1 Virt +77% #1 SAP +3% PCIe Gen 3 Nueva tecnología PCIe Gen 3 permitiendo mayor rendimiento Procesador Hasta dos Intel Xeon E Aumento rendimiento hasta 80% en comparación con la generación anterior. Soporte de todos los procesadores Intel incluyendo los de 135W y de bajo consumo Especificaciones: Hasta 8 cores y 20MB cache Intel Turbo Boost Technology 2.0 Intel Advanced Vector Extensions Hasta dos 8.0 GT/s QPI Links PCIe 3.0 Internal View Up to 8.0 GT/s Memoria Aumento del número de DIMMS de 18 a 24 y de la velocidad máxima de 1333MHz a 1600MHz. Up to DDR = New On E
6 Sell SPECint Down One (Base) Bin for -Lower Intel Price Xeon and 5600 still get vs.. 6% -E % better performance Sell Bin to Bin for Dramatic Performance Increase (26% - 63%) E5603 E5606 E5607 E5620 E5645 E5649 X5650 X5660 X5675 X5690 SPECint (Base) - Intel Xeon 5600 series vs. E series E E E E E E E E E E E Perf: 63% Perf: 101% Perf: 225% Perf: 21% Perf: 50% Perf: 119% Perf: 226% Perf: 255% Perf: 290% Perf: 19% Perf: 115% Perf: 153% Perf: 192% Perf: 220% Perf: 235% Perf: 6% Perf: 55% Perf: 110% Perf: 131% Perf: 151% Perf: 13% Perf: 26% Perf: 69% Perf: 102% Perf: 26% Perf: 59% Perf: 66% Perf: 90% Perf: 10% Perf: 35% Perf: 61% Perf: 65% Perf: 9% Perf: 16% Perf: 53% Perf: 60% Perf: 3% Perf: 9% Perf: 26% Perf: 50% Perf: 65% Perf: 5% Perf: 20% Perf: 32% Table above provides a processor to processor SPECint (Base) performance and processor cost comparison between Intel Xeon 5600 series and E series. Leverage the table as follows: Customer had an E5660 processor and is planning to transition to the E % decline in the processor cost NOTE Cost is based on Intel s cost of the processor and does not include any additional cost associated with the platform in order to implement E series processors
7 Virtualización: Aumento puertos red Posibilidad de hasta siete puertos Ethernet sin usar slot PCI Flexibilidad red: Aumento de puertos y flexibilidad de adoptar tecnología 10GbE con adaptadores de varios fabricantes sin consumir valiosos slots PCI Puertos Ethernet t Estándar con 4x 1GbE y 1x 1GbE IMM Upgrade a tecnología 10GbE Posibilidad de 10Gb NIC a coste de LOM price manteniendo la flexibilidad de un adaptador PCIe. Disponibles soluciones 10GbE de Emulex, Brocade y Qlogic No necesita un slot PCIe Posibilidad de SFP+ y Base-T Internal View 7
8 Tendencias en el entorno de la red Redes separadas para cada tipo de tráfico Costes Hardware: Diferentes adaptadores switches y cableados Díficil en una gestión única red Convergencia tráfico LAN, SAN, y HPC Reducción Costes Reduce costes hardware Mejora eficiencia energética Fácil gestión Gestión única de la red Servidores Entorno red tradicional Convergencia Redes LAN FCoE SAN CEE Destinos Customer Deployment Plans for 10GbE Servidores HP C Redes Destinos Source: IT Brand Pulse Survey, March
9 IBM Virtual Fabric Virtualización flexible de la red 1Gb Solución tradicional 1Gb Nada entre ambas! 10Gb Solución 10Gb Emulex Virtual Fabric Adapter IBM Virtual Fabric 4 puertos virtuales por cada puerto 10Gb Crear y mantener ancho de banda entre 100Mbps y 10Gb! Control ancho de banda FULL DUPLEX 9
10 Virtualización: Ventajas del Virtual Fabric Puertos Ethernet virtuales y convergencia red en una única solución 2.5Gb*2 Crear grupos virtuales y asignar un uplink por grupo Virtual NICs CNA VMWare Service console 2.5Gb*2 Guest VM 2.5Gb*2 VMWare Fault Tolerance Virtual Groups Hasta 8 puertos virtuales Por adaptador Configurar puertos como Virtual CNA No necesaria HBA adicional CNA 2.5Gb*2 VMotion Fácil gestión: Switch Interface, CLI or -Open Fabric Manager 10 Asignar cada adaptador virtual a grupos puertos *Future Upgrade Option 10
11 Virtualización: HS23 dos puertos 10GbE en placa base Hasta 18 puertos conexión Blade Server #n 1GbE Blade Server 1 PCIe 8x CIOv 3 4 1G/10Gb Enet LOM Lane 4 Lane 1 Lane SM1 (Ethernet) SM2 (Ethernet) SM3 PCIe 16x HSDC I/F 4 Lane 10Gb LOM Interposer Card SM4 Switch 7 Switch CFFh HSDC reemplaza 10Gb LOM interposer si Cliente quiere (2+2 10Gb, 2 10Gb+2 IB) Mid-Plane Switch 9 Switch 10
12 Beneficios del IBM Virtual Fabric Reducción de Costes Simplificación Mejora de Rendimiento Reduce coste de adquisición i ió de equipos hasta en un 49% Reduce cables hasta en un 86% Reduce switches y adaptadores Reduce costes de energía hasta en un 50% hasta en un 75% Consolida más máquinas Protección de la inversión, preparada para convergencia virtuales en menos sistemas Mayor disponibilidad y seguridad Mayor ancho de banda de E/S hasta en 10x Asigna ancho de banda de forma dinámica con cero tiempo caída de sistema Menor latencia Basado en estándares de industria
13 Virtualización: Aumento capacidad memoria Mejoras E5: Paso de 3 a 4 canales de memoria. Supone pasar de 18 a 24 DIMMs Soporte LRDIMM de 32GB permite alcanzar 768GB Aumento de la velocidad de 1333MHz a 1600MHz. Depende CPU y tipo DIMM DIMM Cuando usar UDIMM RDIMM Menor latencia y consumo Menor precio Capacidades detección de errores (Chipkill) Máximo rendimiento hasta 1600MHz con 2DPC LRDIMM (Load Reduced DIMM) 16GB Netlist HyperCloud Uso buffer reduce carga eléctrica y mejora rendimiento controlador memoria 32GB DIMM permite alcanzar = 768GB Aplicaciones que necesiten mucha memoria (Virtualización, Bases Datos) Aplicaciones necesiten gran rendimiento y cantidades memoria superiores a 384GB Mayor rendimiento para cantidades memoria entre 256GB y 384GB Aplicaciones financieras/hpc necesiten gran rendimiento. No se puede mezclar RDIMM/UDIMM/HyperCloud/LRDIMM
14 Soluciones Infraestructura: exflash exflash proporciona alta capacidad y rendimiento en el almacenamiento interno Mismo rendimiento que 800 discos giratorios Aumento rendimiento 200x 99% mejor rendimiento Para mismo rendimiento base datos con 1,000 usuarios 97% más barato $670,000 ahorro hardware 40x densidad solución Consumo energético 1% discos giratorios Green IT Ahorro costes exflash exflash exflash exflash exflash Almacenamiento discos estado sólido con controladores disco alta velocidad Fácil servicio Hot-swap y protección RAID Paquetes exflash Hasta 8 x 1.8 SSDs por paquete Disponible en capacidades de 50 GB y 200 GB para alcanzar hasta 1.6TB por exflash y hasta 6.4TB por x3650 M4
15 Ahorro energético: Reducción costes al aumentar eficiencia 41% More energy efficiency 2 Reducción significativa TCO con liderazgo en eficiencia energética. 47,9% Aumento eficiencia energética (2) Nuevos diseños térmicos Nuevos reguladores de voltaje y mayor integración en placa base simplifica distribución de la corriente y disminuye pérdidas Combinación con el IMM, y ventiladores de giro contrario permiten una refrigeración más eficiente con menos gasto de energía en los ventiladores. Control velocidad del ventilador dependiendo temperatura ambiente, altitud, sensores. Energy Star Compliance- Servidores con ENERGY STAR son promedio 30% más eficientes energéticamente que servidores estándar (1). (1) Source: US Environmental Protection Agency Energy Star Website (2)
16 Ahorro energético: IBM Common Form Factor Fuentes alimentación Common Form Factor (CFF), mismas fuentes pueden ser usadas en varios servidores. Beneficios CFF: Redución coste, seleccionar las fuentes de alimentación dependiendo de los requerimientos. Reducción coste operación. Al dimensionar las fuentes de acuerdo con la configuración permite mayor eficiencia. CFF PSU 80PLUS Platinum 20% Load Power 50% Load 100% Load 80PLUS Platinum Compliance 90.00% 94.00% 91.00% IBM 550W 90.45% 94.02% 91.89% Compliant and exceed IBM 750W 92.32% 94.31% 93.14% Compliant and exceed IBM 900W 92.94% 94.21% 92.74% Compliant and exceed 80PLUS link:
17 Fiabilidad: Diseño ventiladores N+N Monitoriza entorno con control velocidad ventilador de acuerdo con temperatura: CPU Memoria Regulador Voltaje Zona PCI Adaptadores Fallos ventilador Ventiladores de bajo voltaje y silenciosos Ventiladores soportan dos zonas térmicas con diseño redundante N+N Velocidad ventilador determinada por temperatura ambiente Cada zona térmica ajusta la velocidad del ventilador en base a los componentes y condiciones térmicas de la zona Indicadores LightPath señalan posibles errores ventiladores Ventiladores redundantes, doble motor permiten mantener condiciones óptimas sistema y mayor tiempo funcionamiento. 1 Zona 1 Zona 2 Zona 1 Zona 2
18 Fiabilidad: Maximizar tiempo de servicio Maximizar tiempo de servicio: Compañías ejecutan aplicaciones críticas de negocio en servidores cuyo coste de pérdida de servicio puede alcanzar los $70k / hour (1). Es vital la elección de un servidor que garantice el máximo servicio. Ventiladores Hot Swap y Redundantes Redundancia N+N para aplicaciones críticas Memory Mirror Proporciona completa protección de la memoria. Beneficioso si se requiere tiempo de servicio máximo. Diseño Tool-less Principales componentes pueden ser reparados sin necesidad de herramientas. Permite reparaciones más rápidas y mayor rapidez en recuperar servicio. Hot Swap y Redundantes Ventiladores, PSU & HDD Permite aumentar tiempo funcionamiento Internal View (1) "Reducing Downtime and Business Loss: Addressing Business Risk with Effective Technology," IDC Whitepaper, August
19 Fiabilidad: Nueva familia adaptadores RAID Nuevas opciones RAID: x3650 M4 tiene RAID en placa base. Beneficios de RAID 0/1 por hardware sin usar slot PCI. Expansión portfolio RAID con más opciones, flexibilidad y rendimiento Estándar ServeRAID 5110e - RAID 0/1 RAID Options Standard w/ ServeRAID 5110e Cacheless RAID 5/50 Upgrade 512MB Cache con RAID 5/50 Upgrades 1GB/512MB Flash con RAID 5/50 Upgrade RAID 6/60 with Upgrade con Feature on Demand Internal View Upgrades Hardware Upgrades Feature on Demand ServeRAID M5100 Series 512MB Cache/RAID 5 ServeRAID M5100 Series Zero Cache/RAID 5 ServeRAID M5100 Series Battery Kit Nueva Tecnología Nueva Tecnología ServeRAID M5100 Series 512MB Flash/RAID 5 ServeRAID M5100 Series RAID 6 Upgrade ServeRAID M5100 Series 1GB Flash/RAID 5 ServeRAID M5100 Series SSD Performance Accelerator ServeRAID M5100 Series SSD Caching Enabler 19
20 Fiabilidad: Opciones adaptadores RAID Optimización SSD Incremento Rendimientot / Caching Módulos Flash 512MB, 1GB RAID 5/50 Enterprise Sin batería / No consumibles Módulo Batería Li-Ion Protección información 48 Horas Llave RAID 6/60 RAID 6/60 Enterprise Módulo Cache 512MB RAID 5/50 Enterprise RAID 5 Upgrade RAID 5 Embebido SW License C100 RAID 0/1/10 embebido Hasta 8-Bay SATA H1110 RAID 0/1/10 Value 4 Bay Interno RAID 5 Upgrade Upgrade RAID 5/50 Sin cache / Sin batería M1115 RAID 0/1/10 Entry 8 Bay Interno RAID 5 Upgrade Upgrade RAID 5/50 Sin cache / Sin batería M5110/M5110e R0/1/10 Enterprise 8 Bay Interno M5120 R0/1/10 Enterprise 8 Bay Externo Entry Value Enterprise Flexibilidad Posibilidad de crecimiento desde una base única Ofertas para múltiples servidores Rendimiento Mayores tamaños de cache, integración tecnología flash 20
21 Flexibilidad: Features on Demand FoD Qué es? Posibilidad de activar ( unlock ) opciones integradas en productos System x Opción está en el firmware o software pero bloqueada locked hasta que el usuario compra y activa la clave de activación Opciones System x activadas via proceso FoD Opciones deben comprarse a través de canales normales Objetivo Fácil usar Instalación sencilla Customer or Partner 1 Place order Receive paper (and optional ) with authorization 2 IBM Submit authorization From request to authorization takes only 24 hours Fulfillment Request key Generate key Key Mgmt System Receive activation key 3 Install key
22 Disponibilidad: Predictive Failure Analysis (PFA) & Light Path Diagnostics Predictive Failure Analysis (PFA) : Permite monitorizar componentes claves del sistema y generar una alerta hasta 48 horas antes de que ocurra el fallo. Light Path Diagnostics: Identificar rapidamente el componente que falla Permiten realizar un hot-swap del componente (si es posible) o planificar la parada cuando el impacto sea menor. IBM implementa PFA en más componentes que cualquier otro vendedor. System x con PFA son: Discos! Ventiladores Power Supply Units Memoria CPU s VRM- Módulos reguladores voltaje Panel frontal Light Path Diagnostics Luz indica que hay un problema con el servidor Pop-Out Light Path Diagnostics Panel Indica el subsistema que tiene el problema Light Path Diagnostics Nivel componente 22
23 Seguridad: Diseño innovador del nuevo IMMv2 Feature on Demand para IMMv2 Tres niveles gestión Basic Standard* Presencia remota Advanced* Interfaz móvil Aumento Seguridad CRTM (core root of trust measurement) en arranque. TPM dentro IMMv2 (trusted platform module) IMMv2 acepta solo trusted signed actualizaciones Fácil Serviciabilidad Text Logs Alertas First Failure Data Capture Mejoras en IMMv2 Diseño HW Rendimiento & Fiabilidad Más rápido Power On 33% más rápido Boot Blades 25% más rápido Boot Rack IMM-UEFI Boot separado Nota: IMM actual & IMMv2 firmware no intercambiable 23
24 Protección entorno con menor TCO Feature on Demand No opciones físicas No necesario envío No opciones sin usar Operating temperature Modelos con procesador 60-95W soportan 5-40C Ahorro aire acondicionado Ahorro energía Nuevas CFF Power Supplies 80 PLUS platinum power supplies +94% efficiencia Ahorro consumo energético Mejor diseño térmico y energético Mejora de 40% en benchmark SPECpower sobre generación anterior FoD 94% 40 o C +40% Pay-as-you-grow Upgrade cuando se necesita, Consumo energía sólo cuando se instala 24
25 IBM completes the rollout of its most comprehensive x86 systems portfolio New 4 socket entrant optimized for price / performance and density System x3750 M4 New entry level portfolio improves the economics for growing businesses running small to mid-sized solution workloads System x3630 M4 BladeCenter HS23E System x3530 M4 Flexible 2U server for storage rich or general business workloads Dense, cost-optimized 1U for general business workloads Ideal blade for entry virtualization and infrastructure workloads
26 IBM System x3630 M4 Low-cost server for general business and storage-dense applications Benefits Business flexibility Optimize for cost or performance Performance Up to 170% more performance than one socket servers for growing businesses¹ Easy expandability Add features as your business grows Partner for success Choose the top IT partner to safely run your business ¹According to Intel performance results ²As ranked by Interbrand Available 3Q Key Features Upgrade Ethernet ports, RAID capabilities, availability or remote management capabilities to fit your business needs Intel Xeon E product family, up to two 8-core, 95 watt processors Up to 42TB of hot swap storage and up to 384GB 3 memory #1 global technology brand 2 42TB Max Storage 384GB Max Memory Optional 80PLUS Platinum Feature on Demand
27 IBM System x3530 M4 Dense, entry 2-socket server for general business workloads Benefits Business flexibility Optimize for performance and cost Performance Up to 170% more performance than one socket servers for growing businesses¹ Efficiency Lower total cost of ownership Partner for success Choose the top IT partner to safely run your business Key Features Choice of 2.5 or 3.5 hard drives. Upgrade Ethernet ports, RAID capabilities, and more to fit your business needs Intel Xeon E product family, up to two 8-core, 95 watt processors All Power supplies meet 80-PLUS certification #1 global technology brand 2 Up to 4x 3.5 Drives Feature on Demand 80PLUS Power supplies 384GB Max Memory 3 ¹According to Intel performance results ²As ranked by Interbrand Available 3Q
28 IBM BladeCenter HS23E Ideal blade for entry virtualization and infrastructure workloads Benefits Lower costs Up to 10% savings compared to HS22* Enhanced performance Up to 42% more compute power** Simple setup Accelerate time to value Breakthrough networking flexibility Built in support for multiple technologies Complete investment protection Add capability to existing investments Key Features Rich and robust I/O networking capabilities* Intel Xeon processor E product family IBM FastSetup wizard tool for day 0 deployments Up to 8 networking ports of Ethernet, FCoE, and iscsi Support for existing chassis infrastructure 10% Savings vs HS22 192GB Max Memory 42% More performance 100% BladeCenter Chassis Support *compared to similar performing systems **versus previous generation
29 Comparing Two Platforms for Different Customer Needs Intel Xeon processor E7 family Top of the line enterprise performance Richest Xeon RAS feature set to support mission critical applications Highest memory capacity Best for enterprise apps (database, BI, virtualization, etc) needing large, scaleup servers Scales 2S, 4S, 8S natively and beyond 8S with customer node controllers Intel Xeon processor E product family Optimized for higher density Lower system price points 1 Excellent floating point performance and performance per watt (PPW) 1 Best for dense 4- socket designs, 4- socket HPC apps, and entry 4-socket servers 1 Source: Intel internal assessment 29 INTEL INTENAL USE ONLY DRAFT DO NOT DISTRIBUTE
30 IBM System x3750 M4 Streamlined 4-socket design, optimized for price / performance and density Benefits Performance Perfect for clients looking to grow from 2-socket EP systems as well as for HPC and floating-point intensive applications Business flexibility Optimized for performance and cost Advanced I/O Optimized for performance and connectivity Investment protection Pay as you grow processing and I/O Key Features Intel Xeon processor E product family, up to four 8-core processors; 25% higher memory performance than competitive systems* Up to 1.5 TB memory, 2.5 HS drives, exflash SSD technology Up to 32 exflash SSDs, available 10GbE copper or fiber, Virtual Fabric *1333MHz vs 1066MHz at 3 DPC (RDIMMs) and at 1, 2 and 3 DPC (LRDIMMs) Expandable 2+2 socket and 5+3 PCI design exflash SSD * E More CPU Performance processing 25% Higher memory Performance*
31 Por qué IBM? Source: Technology Business Research - x86-based Servers: Corporate IT Buying Behavior & Customer Satisfaction Study Fourth Quarter 2011
32 IBM System x and BladeCenter: Innovación a todos los Scalable Systems Large niveles symmetrical multiprocessing (SMP) x3850 X5 Intelligent Cluster idataplex Clusters, HPC, Virtualization, Web 2.0 & Cloud dx360 M4 x3690 X5 High density Scale up computing x3755 M3 HX5 x3650 M4 x3400 M3 x3500 M4 x3630 M3 x3550 M4 x3620 M3 x3100 M4 X3250 M4 Scale out / distributed computing HS23 BladeCenter S, E, H, T, HT HS22/HS22v//23/HX5 3
33 IBM System x3650 M4 System x3650 M4 Processors Sandy Bridge EP up to 8 cores #Socket 2 Form factor 2U Rack Memory Slots Max Memory Media bays Disk Drive type HDD bays RAID NIC/TPM 24 slots (UDIMM/RDIMM) Up to 768GB Optional DVD and Tape Bay SAS/SATA/SSD 16x 2.5 or 6x 3.5 HDDs RAID on Motherboard 4x 1Gb (std.) + 2x 10Gb (slotless opt.) /TPM Soporte todos los procesadores E Gran capacidad memoria Tecnología exflash Variedad opciones red Flexible protección RAID PCIe (x16/x8) Power USB ports VGA ports Fan Design Light Path System MGMT Warranty 3-6 PCIe ports (2/2, 1/4 or 0/6) or 4 PCI-X or 2 Double Width PCIe support w/ Slotless 10 Gb NIC and RAID AC 750W/900W550W, DC 750W Up to 80 plus Platinum 2 front/4 back/2 internal 1 front/1 back 4x Hot swap redundant fans Light Path panel in front IMMv2, dedicated LAN port 3 years (parts/labor) 33
34 Comparativa x3650m3 y x3650m4 x3650 M3 x3650 M4 Beneficios Procesador Intel Xeon 5600 series core y 6 core 1 QPI Lane Intel E series 135W 8-core 2 QPI Lanes Aumento rendimiento Memoria 3 canales por CPU 1.5V ó 1.35V Max 1333MHz 4 canales por CPU 24 slots RDIMM 16 slots UDIMM 1.5V ó 1.35V Max 1600MHz Max. 768GB LRDIMM Max. 64GB UDIMM LR DIMMs Aumento memoria permite mayor número de VMs y aplicaciones más rápidas Mayor número de opciones de memoria Disco (opcional) tape (opcional) & Tape (opcional) SAS/SATA SSD* RAID en Planar Opciones flexibles de almacenamiento Aumento capacidad de almacenamiento Opciones RAID mejoradas Opcional exflash I/O 2 configuración 4-6 slots dependiendo de la configuración 1 CPU 2 CPU Adaptador slotless 10Gb (opcional) Soporte 2 GPU Mayor número PCIe Soporte GPU Power 550W, 750W, 900W Redundante Platinum level Opciones de fuentes de alimentación adicionales Eficiencia energética Misc. 3 *Post GA Support IMM IMM2 Ethernet Gigabit Cuatro Puertos Componentes FoD Gestión escalable Dobla la conectividad Upgrades simples y económicos
35 Comparativa x3550m3 y x3550m4 Procesador Memoria Disco I/O Power Misc. x3550 M3 x3550 M4 Beneficios Intel Xeon 5600 series core y 6 core 1 QPI Lane 3 canales por CPU 1.5V ó 1.35V Max 1333MHz Redundante IMM Intel E series 8-core 2 QPI lanes 4 canales por CPU 24 slots RDIMM 16 slots UDIMM 1.5V ó 1.35V Max 1600MHz Max. 768GB LRDIMM Max. 64GB UDIMM LR DIMMs SAS/SATA 1 CPU CPU) Adaptador slotless 10Gb (opcional) 550W, 750W, Fuente Alimentación Redundante Platinum level IMM2 Ethernet Gigabit Cuatro Puertos Componentes FoD Aumento rendimiento Aumento memoria permite mayor número de VMs y aplicaciones más rápidas Mayor número de opciones de memoria Opciones flexibles de almacenamiento Aumneto capacidad de almacenamiento Opciones RAID mejoradas Mayor número PCIe Opciones de fuentes de alimentación adicionales Eficiencia energética Gestión escalable Dobla la conectividad Upgrades simples y económicos 3
36 Comparativa x3400m3, x3500m3 y x3500m4 Procesador Memoria Disco I/O Power Misc. 3 x3400 M3 x3500 M3 x3500 M4 Beneficios Intel Xeon 5600 series core y 6 core 1 QPI Lane 3 canales per CPU 1.5V ó 1.35V Max 1333MHz Hasta (opcional) Redundante IMM * Post GA Intel Xeon 5600 series core y 6 core 1 QPI Lane 3 canales per CPU 1.5V ó 1.35V Max 1333MHz IMM Intel E series 8-core 2 QPI lanes 4 canales per CPU 24 slots RDIMM 16 slots UDIMM 1.5V ó 1.35V Max 1600MHz Max. 768GB LRDIMM Max. 64GB UDIMM LR DIMMs SAS/SATA (opcional) 1 CPU 2 CPU 2 x16 adicional 550W*, 750W & 900W Platinum PSU Redundante IMM2 Ethernet Gigabit cuatro Puertos Componentes FoD Aumento rendimiento Aumento memoria permite mayor número de VMs y aplicaciones más rápidas Mayor número de opciones de memoria Opciones almacenamiento Aumento capacidad almacenamiento Más opciones RAID 2 x16 adicionales Opciones fuentes alimentación adicionales Eficiencia energética Gestión escalable Dobla la conectividad Upgrades simples y económicos
37 Comparativa HS23 con HS22 y HS22v HS22 HS22V HS23 Procesador 2-Socket Intel Nehalem / Westmere-EP 2-Socket Intel Nehalem / Westmere-EP 2-Socket Intel Sandy Bridge / Romley-EP # DIMMs 12 Disco 2 x HS 2.5 (SAS/SATA/SSD) 2 x SSD 1.8 Non-hot swap 2 x HS 2.5 (SAS/SATA/SSD) Ethernet Broadcom 5709s Broadcom 5709s Emulex Server Engines BE3 Dual 10Gb/1Gb I/O 1 x CIOv 1 x CFFh/CIOh 1 x CIOv 1 x CFFh/CIOh 1x CIOv 1x CFFh/CFFL Chasis BCH, BCS, BCTH, BCE-R BCH, BCS, BCTH, BCE-R BCH-R, BCS, BCHT, BCE-R* 3 * Tigershark = thermal limitations in BCE-R; testing in progress
38 IBM System x3550 M4 Rich networking options Support for Intel Xeon E processors Optimized for density and performance System x3550 M4 Processors Sandy Bridge EP up to 8 cores #Socket 2 Form factor 1U Rack Memory Slots Max Memory Media bays Disk Drive type HDD bays RAID NIC/TPM 24 slots (UDIMM/RDIMM) Up to 768GB DVD Bay (Optional w/ 2.5 HDDs) SAS/SATA/SSD 8x 2.5 or 3x 3.5 HDDs Slotless RAID 4x 1Gb (std.) + 2x 10Gb (slotless opt.) /TPM PCIe (x16/x8) 2 PCIe ports (1/1 or 2/0) + Slotless 10 Gb NIC and RAID Power USB ports VGA ports Fan Design Light Path System MGMT Warranty AC 550W/750W, DC 750W Up to 80 plus Platinum 2 front/4 back/2 internal 1 front/1 back 6x Hot swap redundant fans Light Path panel in front IMMv2, dedicated LAN port 3 years (parts/labor) 38
39 IBM System x3500 M4 System x3500 M4 Processors Sandy Bridge EP up to 8 cores #Socket 2 Form factor Tower (5U rack option) Memory Slots Max Memory Media bays Disk Drive type HDD bays RAID NIC/TPM PCIe Power I/O Ports Fan Design Light Path System Mgmt. Warranty 24 slots (UDIMM/RDIMM) Up to 768GB Standard DVD-ROM and Tape Bay 2.5 SAS/SATA or 3.5 SATA Up to 32x 2.5 or 8x 3.5 HDDs 6Gb Cache RAID: M5115 or M5125 RAID 0,1,10,5,50 optional 6,60 4x 1Gb + 2x 10Gb(opt.) /TPM Std. Up to 8 PCI slots From Proc. 1: 1 PCIe Gen2 x16 (Up to 225W), 4 PCIe Gen2 x8 (2 with Elec x4), 1 PCIe Gen2 x8 (Elec x4) From Processor 2: 2 PCIe Gen2 x 16 (Up to 225W) Optional: 1 PCI-X (by interposer card) Redundant 750W/900W, 80 plus Platinum USB: 2 front/4 back/2 internal 1 Serial port, 1 VGA port 3+3 Simple swap redundant fans Front Light Path Diagnostic IMM v2 with dedicated port 3 years (parts/labor) 39
40 HS23 HS23 Processor Support Intel Xeon E Series processors (Up to 130W) Up to two 2.7GHz (8-core) or 2.9GHz (6-core) processors Memory 16 DIMMs (up to 256GB) 2 DPC@1600Mhz Support 1.35V & 1.5V DIMMs Storage 2 x HS 2.5 (SAS/SATA/SSD) I/O Sys. Mgmt. Ethernet Chasis 1x CIOv 1x CFFh/CFFL IMM v2, IBM Fastsetup Emulex Server Engines BE3 Dual 10Gb/1Gb Up to 18 ports of I/O (physical + virtual ports) Run multiple protocols (FCoE/iSCSI) BCH, BCS, BCHT, BCE-R 40
41 Diseño innovador con nuevas opciones 4x 3x 2x Aumento ancho banda RAID de PCIe Gen2 x4 to Gen3 x8 Capacidad Memoria incrementada de 288GB a 768GB Velocidad memoria aumentada de 1333MHz a 1600MHz Capacidad Disco de 8TB a 16TB w/ Cinta y ODD RAID cache aumentado de 512MB a 1GB 82% Mejora Rendimiento % SPECfp_rate_base % SPECint_rate_base % SAP-2T 41
42 System x Servidores NEW 1 y 2 procesadores System x3650 M4 eneral Business idataplex dx360 M4 igh Performance System x3550 M4 NEW System x3500 M4 NEW System x3755 M3 NEW Hasta 8 cores por CPU Hasta 768GB de memoria 10Gb networking Diseño RAID flexible Optimizado para HPC Hasta 4 CPUs por 2U System x3630 M3 Value 2-socket System x3620 M3 System x3400 M3 Hasta 6 cores por CPU Hasta 192GB de memoria Máxima capacidad almacenamiento System x3100 M4 ntry 1-socket System x3250 M4 Precio entrada Hasta 32GB de memoria 42
43 Formato y altura Procesador (máx.) Número de procesadores (de serie/máx.) Caché (máx.) Memoria (máx.) Bastidor de 2U Hasta cuatro procesadores Intel Xeon de la serie E de 4, 6 u 8 cores Cuatro Hasta 20 megabytes (MB) por procesador Hasta 1,5 terabytes (TB) a través de 48 ranuras con LR-DIMM de 32 gigabytes (GB) Cinco ranuras x8 PCIe Gen3 de perfil bajo. Tres ranuras x16 (mecánicas) x8 Ranuras de expansión (eléctricas) de altura completa/media altura PCIe Gen3 opcionales en la expansión de la extensión Bahías para soportes Unidad DVD opcional Bahías de discos (total/hot-swap) Hasta 16 HDD de 2,5" o hasta 32 SSD * exflash de 1,8" Almacenamiento interno máximo Hasta 16 TB (HDD de 2,5"), 6,4 TB (SSD exflash de 1,8") Interfaz de red Fuente de alimentación (de serie/máx.) Componentes hot-swap Soporte RAID Controladora integrada que admite dos puertos de 1 GbE (de serie) y opciones de cobre o fibra duales de 10 GbE 900 W o 1400 W (1 de serie, 2 como máximo) Módulos de ventilación, HDD, SSD exflash, fuente de alimentación Array redundante de discos independientes (RAID) IBM ServeRAID-M5110e en la placa base, hardware a 6 gigabits por segundo (Gbps) integrado. RAID-0/-1 (de serie) con actualizaciones de -5/-50 y -6/-60 Gestión de sistemas Puertos USB Puertos VGA Sistemas operativos compatibles Garantía limitada IBM Integrated Management Module v2 (IMM2) con presencia remota, Análisis predictivo de fallos (PFA), diodos emisores de luz (LED) de diagnóstico, panel Light Path Diagnostics, Automatic Server Restart, IBM Systems Director Active Energy Manager Dos frontales/dos traseros/dos internos Uno frontal/uno posterior Microsoft Windows Server, Red Hat Enterprise Linux (RHEL), SUSE Linux Enterprise Server (SLES), VMware vsphere Tres años de unidad sustituible por el cliente (CRU) y garantía in situ limitada, respuesta al siguiente día laborable de 9:00 a 17:00, actualizaciones de servicio disponibles 28/12/2012
44 Formato y altura Bastidor de 1U Procesador (máx.) Hasta dos procesadores Intel Xeon de la serie E de 8 cores Caché (máx.) 20 megabytes (MB) por procesador Memoria (máx.) Hasta 192 gigabytes (GB) a través de 12 ranuras (Unregistered Dual Inline Memory Module (UDIMM)/Registered DIMM (RDIMM)) Bahías para soportes Una bahía de DVD opcional para el modelo de 2,5" Bahías de disco Ocho HDD de 2,5" o cuatro de 3,5" Soporte RAID Software integrado RAID-0, -1, -10 de 3 gigabits por segundo (Gbps); RAID-0, -1, -10 por hardware opcional o RAID-5, -50 o -6, -60 Fuente de alimentación (de serie/máx.) Una fuente de alimentación fija de 460 W o hasta dos fuentes de alimentación redundantes hot-swap de 460 W o 675 W Componentes hot-swap Fuentes de alimentación, módulos de ventilación y unidades de disco duro Interfaz Peripheral express (PCIe) 2 ranuras PCIe (x16/x8) (1/0 o 0/2) + PCIe x4 para RAID sin necesidad de ranuras Ranuras de expansión 2 ranuras PCIe 3.0 Interfaz Ethernet Controladora Intel Ethernet I350 Dual de 1 gigabit (Gb) en la placa + Intel I-350 Embedded Dual-Port Gb Ethernet (GbE) Activation para IBM System x (FoD) Puertos VGA Una delantera (opcional para los modelos de HDD de 3,5", según el modelo)/una trasera Puertos USB Siete (dos x frontales, cuatro traseros, uno interno) Almacenamiento interno máximo Gestión de sistemas Sistemas operativos compatibles Garantía limitada Unidades Serial Attached SCSI (SAS)/Serial Advanced Technology Attachment (SATA) de hasta 8 terabytes (TB) (modelo de 2,5") o SAS/SATA de 12 TB (modelo de 3,5") IMM2 de IBM con FoD de actualización opcional para presencia remota, Predictive Failure Analysis (PFA), diodos emisores de luz (LED) de diagnóstico, Light Path de serie con kit avanzado opcional, IBM Systems Director y Active Energy Manager (según el modelo) Microsoft Windows Server, Red Hat Enterprise Linux (RHEL), SUSE Linux Enterprise Server (SLES), VMware vsphere Tres años de unidad sustituible por el cliente (CRU) y servicio in situ al siguiente día laborable de 09:00 a 17:00, actualizaciones de servicio disponibles 28/12/2012
45 Form factor/height 2U Rack Processor (max) 2-, 4-, 6-, 8-core Intel Xeon processor E product family, up to 1600 MHz memory access speed Number of processors (std/max) 1/2 Cache (max) Up to 12 MB L3 Memory (max) Up to 192 GB DDR-3 RDIMM memory via 12 DIMM slots Expansion slots 2-4 x8 PCIe slots +x4 slotless RAID Disk bays (total/hot-swap) Maximum internal storage Network interface Power supply (std/max) Hot-swap components RAID support Systems management Operating systems supported Warranty 4, 8 x 3.5" simple-swap SATA HDDs or 8 x 3.5" hot-swap SAS/SATA HDDs +tape (value model), 12+2x 3.5 hot-swap (storage-rich model) Up to 24 TB disk (value model), up to 42 TB (storage-rich model) Intel Ethernet Controller I350 Dual 1Gb on board + Intel I-350 Embedded Dual Port GbE Activation for IBM System x Feature on Demand (FoD) Up to two 550 W/750 W 80 PLUS certified PSU Power supplies, hard disk drives Integrated 3 Gbps software RAID-0, -1, -10 for value entry model; optional hardware RAID-0, - 1, -10 or RAID-5, -50 or -6, -60 IBM Systems Director, IBM Systems Director Active Energy Manager, IMM (Integrated Management Module) with IPMI 2.0 support, UEFI (Unified Extensible Firmware Interface), IBM ToolsCenter, status LEDs Microsoft Windows Server, Red Hat Linux, SUSE Linux, VMware 3-year customer replaceable unit and onsite limited warranty, next business day 9x5, service upgrades available 28/12/2012
46 IBM BladeCenter HS23E Formato y altura Procesador (máx.) Número de procesadores (de serie/máx.) Caché (máx.) Memoria (máx.) Ranuras de expansión Bahías de discos (total/hot-swap) Almacenamiento interno máximo Interfaz de red Soporte RAID Gestión de sistemas Sistemas operativos compatibles Garantía limitada Ancho simple (30 mm) Familia de productos E con procesador Intel Xeon, con hasta ocho cores y procesamiento de hasta 16 subprocesos simultáneos Uno/dos 20 megabytes (MB) Capacidad: 12 ranuras DIMM a 192 GB Velocidad: DDR-3 con detección y corrección de errores (ECC) de perfil muy bajo (VLP), a 1333 o 1600 MHz, duplicación de memoria y asistencia de recambios Una ranura CIOv (tarjetas secundarias Peripheral Component Interconnect Express (PCIe) de serie) y una ranura CFFh (tarjeta secundaria PCIe de alta velocidad) Dos unidades de estado sólido (SSD) o unidades de disco duro (HDD) hot-swap 2 Terabytes (TB) (supone unidades de 1 TB) Tarjeta de interfaz de red (NIC) en placa Broadcom 5718 con dos puertos GbE con TCP/IP Offload Engine (TOE) RAID-0, -1: opción de software y hardware de RAID Unified Extensible Firmware Interface (UEFI), IBM Integrated Management Module (IMM), Predictive Failure Analysis (PFA), hypervisor integrado opcional para virtualización, IBM Systems Director Active Energy Manager, Light Path Diagnostics, IBM Systems Director, IBM ServerGuide, UpdateXpress, Dynamic System Analysis con Integrated RT Diagnostics, BladeCenter Open Fabric Manager (BOFM) Microsoft Windows Server, Red Hat Enterprise Linux (RHEL), SUSE Linux Enterprise (SLE), VMware Tres años de unidad sustituible por el cliente (CRU) y garantía in situ limitada, respuesta al siguiente día laborable de 9:00 a 17:00, actualizaciones de servicio disponibles 28/12/2012
47 Ivan Campos IBM sales specialist Tlf.: Móvil:
CUENTA DE ALTO COSTO Convenio de Administración
ANEXO DOCUMENTO TECNICO DE REQUERIMIENTOS PARA LA CONTRATACION DE UN DATA CENTER I. NECESIDAD DEL SERVICIO Mediante el decreto 2699 del 13 de julio 2007 el estado creó la Cuenta de Alto Costo y delegó
Más detallesInfraestructura de Redes. Microprocesadores
Infraestructura de Redes Microprocesadores Infraestructura Serie 3400 Supere la etapa de las PC de desktop con el desempeño avanzado de los servidores equipados con procesadores Intel Xeon serie 3400.
Más detallesA=:C17=<3A /D/<H/2/A >/@/ 3: >@3A3<B3 G 3: 4CBC@= SERVIDORES BLADE DELL POWEREDGE SERIE M
A=:C17=@3A3
Más detallesRedes y Telecomunicaciones
Universidad Tecnológica de Tijuana Redes y Telecomunicaciones Tarea 1: COTIZACION DE UN SERVIDOR PROF. RAFAEL AVILES Sánchez Acevedo Víctor Hugo 5to B 01/02/10 Cotización de un Servidor Unit Price: $45,523
Más detallesOther Drives. Processor. More Information
Brand Sun CD / DVD Type DVD-ROM Form Factor Rack-mountable Hard Drive Interface FC-AL Manufacturer Part Number A30-WTF4-08GRF Type UltraSPARC III Cu RAM Type SDRAM Storage Controller (2nd) SCSI Audio /
Más detallesPart # Description Dealer Price End User Price
Komplek Perkantoran Duta Pertiwi Blok H2 No.7 Jl. Mangga Dua Dalam, Jakarta 10730, Indonesia Phone: (021) 612-9889 & 612-1818 Fax: (021) 612-6554 SMS Center: 0818 0608 9000 Effective June 2012 Part # Description
Más detallesServidores de Red Genéricos Arquitectura basada en X86
de Red Genéricos Arquitectura basada en X86 CARACTERÍSTICAS GENERALES CODIGO ETAP: SR-001 Se incluyen las Consideraciones Especiales para servidores definidas en CESP-001, CESP- 002, CESP-005, y de corresponder
Más detallesÁREA DE NUEVAS TECNOLOGÍAS Informática
PLIEGO DE PRESCRIPCIONES TÉCNICAS PARA LA AMPLIACIÓN DE LA INFRAESTRUCTURA DE SERVIDORES Y ALMACENAMIENTO. A) OBJETO DEL CONTRATO. El objeto del presente contrato es la adquisición del equipamiento informático
Más detallesPRIMERGY Valor. Julio 2013 PRIMERGY RX300 S7. Virtualización óptima. PVPR - Precios de venta al público recomendados
PRIMERGY RX300 S7 Virtualización óptima Completa tu servidor con: PRIMERGY Valor Servidores / Almacenamiento / LIcencias / Accesorios Julio 2013 PVPR - Precios de venta al público recomendados Flexibilidad,
Más detallesLaboratorio Nacional de Cómputo de Alto Desempeño: Fortalecimiento de la Infraestructura 2015
Anexo A. Partida 3 Laboratorio Nacional de Cómputo de Alto Desempeño: Fortalecimiento de la Infraestructura 2015 CLUSTER LANCAD3 El bien a adquirir se describe a continuación y consiste en cúmulo de supercómputo
Más detallesSistemas de Información. Junio de 2015
Sistemas de Información Junio de 2015 Pliego de prescripciones técnicas aplicable al suministro e instalación de servidores departamentales y otro equipamiento hardware para las plataformas de ejecución
Más detallesConsejo del Poder Judicial del Estado de Michoacán ANEXO 1 Bases técnicas para la adquisición de equipo tecnológico
PARTIDA 1 1 2 1 Instalación de red de datos en edificio para juzgados orales penales anexo al Cereso "David Franco Rodríguez" en Morelia. 160 Nodos de red Ethernet con cableado categoría 6. Incluye Jacks,
Más detallesAplicaciones redundantes mediante el uso de software de alta disponibilidad y tolerancia a fallos everrun
Aplicaciones redundantes mediante el uso de software de alta disponibilidad y tolerancia a fallos everrun El diseño y la implementación de soluciones redundantes en entornos de industria e infraestructuras
Más detallesIBM BLADECENTER. LA ALTERNATIVA CORRECTA.
IBM BLADECENTER. LA ALTERNATIVA CORRECTA. _DIA 15: Cansado de la gran cantidad de información sobre blades. Es hora de ver realmente cómo se comportan los Servidores IBM BladeCenter. Es hora de definiciones.
Más detallesPROCESO DE SELECCIÓN 006 DE 2011 LICITACIÓN PÚBLICA FICHA TÉCNICA
PROCESO DE SELECCIÓN 006 DE 2011 LICITACIÓN PÚBLICA FICHA TÉCNICA La siguiente es la descripción técnica detallada y completa del objeto a contratar, conforme lo dispone el numeral 1 del artículo 6 del
Más detallesANEXO II: ESPECIFICACIONES TÉCNICAS
ANEXO II: ESPECIFICACIONES TÉCNICAS Anexo II EXPEDIENTE Nº 071 Título contrato: Adquisición de Equipos de Cómputo y Servidores para la APCI LOTE 1: 16 EQUIPOS DE CÓMPUTO Número ofrecidas Notas, observaciones,
Más detallesPLIEGO DE CONDICIONES TÉCNICAS
PLIEGO DE CONDICIONES TÉCNICAS SUMINISTRO Y MIGRACIÓN DEL ACTUAL SISTEMA DE VIRTUALICACIÓN MICROSOFT HYPER-V A VMWARE VSPHERE PARA EL AYUNTAMIENTO DE SABIÑANIGO 1 OBJETIVO DEL CONTRATO El presente pliego
Más detallesGestión inteligente. Rafael Bolívar Arenas Cross-Domain Sales Engineer Channel Spain
Gestión inteligente Rafael Bolívar Arenas Cross-Domain Sales Engineer Channel Spain Dell y la gestión de sistemas Consolas Dell (Dell Mgmt Console, OpenManage Essentials, KACE appliance) idrac with Lifecycle
Más detallesThinkServer RS140 Photography
ThinkServer RS140 Photography ThinkServer RS140 Platform Specifications Components Specification Dimensions 1U rack. Height: 43.5 mm (1.71 in), width: 430 mm (16.9 in), depth: 411 mm (16.2 in) Weight Maximum
Más detallesLaboratorio Nacional de Cómputo de Alto Desempeño: Fortalecimiento de la Infraestructura 2015
Anexo A. Partida 2 Laboratorio Nacional de Cómputo de Alto Desempeño: Fortalecimiento de la Infraestructura 2015 CLUSTER LANCAD 2 El bien a adquirir se describe a continuación y consiste de un cúmulo de
Más detallesADQUISICIÓN AMPLIACION DE: PAQUETE INTEGRADO DE HARDWARE Y DE LICENCIAS DE SOFTWARE PLIEGO DE ESPECIFICACIONES TÉCNICAS PARTICULARES
EXPEDIENTE Nº 11164 DIG. 7 AÑO 13 CUERPO 1 Fs. LICITACIÓN PÚBLICA N 12/13 ADQUISICIÓN AMPLIACION DE: PAQUETE INTEGRADO DE HARDWARE Y DE LICENCIAS DE SOFTWARE PLIEGO DE ESPECIFICACIONES TÉCNICAS PARTICULARES
Más detallesDavid Margolles BDM Almacenamiento. 40 aniversario de Fujitsu en España 400 años de relaciones España - Japón
David Margolles BDM Almacenamiento 40 aniversario de Fujitsu en España 400 años de relaciones España - Japón Subtitle Soluciones Almacenamiento para HPC Qué ocurre en internet en un minuto? 2 La situacion
Más detallesUNIVERSIDAD TECNOLOGICA ECOTEC DIEGO BARRAGAN MATERIA: Sistemas Operativos 1 ENSAYO: Servidores BLADE
UNIVERSIDAD TECNOLOGICA ECOTEC DIEGO BARRAGAN MATERIA: Sistemas Operativos 1 ENSAYO: Servidores BLADE AÑO: 2010 Qué es un servidor Blade? Blade Server es una arquitectura que ha conseguido integrar en
Más detallesEspecificaciones Técnicas
Servidor de Terminales Marca del Equipo: Modelo del Equipo: Placa Madre Deberá soportar hasta 2 (dos) procesadores Procesador Especificaciones Técnicas Modelo Intel Xeon Quad Core, línea 5500, velocidad
Más detallesSoluciones que aportan valor a la seguridad de los datos. Soluciones integradas para empresas
Soluciones que aportan valor a la seguridad de los datos. 1 2 3 4 Causas de no disponibilidad de los datos Consolidación del almacenamiento Virtualización de servidores Sistemas centralizados y desatendidos
Más detallesSoporta RAID 5/6 100 de descuento* FSP:GA4S20ZPOESY12 4 años in situ NBD 142 FSP:GA5S20Z00ESY12 NOVEDAD
Modelo PRIMERGY TX100 S2 PRIMERGY TX100 S2 PRIMERGY TX140 S1 PRIMERGY TX140 S1 Soporta RAID 5/6 100 de descuento* Código VFY:T1001SX480IN VFY:T1002SX030IN VFY:TX1401SC010IN VFY:TX1401SC020IN Procesadores
Más detallesGUÍA DE LA GAMA DE SERVIDORES LENOVO
GUÍA DE LA GAMA DE SERVIDORES LENOVO Tendencias de mercado El mercado de sistemas empresariales ha sufrido una transformación significativa en los últimos 30 años. Uno de los cambios más relevantes es
Más detallesArrow ECS Iberia Oracle Demo Centre
Arrow ECS Iberia Oracle Demo Centre Con el fin de ofrecer a nuestros clientes un recurso incomparable para presentar las soluciones Oracle, Arrow ECS ha invertido más de 1 millón de euros en dotarse con
Más detallesInnovación y eficiencia en el Data Center. Luis Palacios Director grupo Infraestructura
Innovación y eficiencia en el Data Center Luis Palacios Director grupo Infraestructura El DC: Activo estratégico para el negocio Agilidad del Negocio Negocio 24x7 Seguridad y Compliance Reducciones Presupuestarias
Más detallesTecnología HyperThreading, Intel Turbo Boost Technology
Hewlett Packard (637391 B21) HP ProLiant BL460c G7 Servidor compacto 2 vías 1 x Xeon E5649 / 2.53 GHz RAM 6 GB SAS hot swap 2.5" sin disco duro MGA G200 Gigabit Ethernet, 10 Gigabit Ethernet Monitor :
Más detallessmall box big storage
small box big storage A Drobo se le conoce por Sofisticación galordana Tecnología patentada BeyondRAID, y otras Hot swap, migración entre Drobos, data aware Thin Provisioning, avanzado y automatizado Disco
Más detallesEspecificaciones Técnicas para la Adquisición de Elementos de Computación ITEM 1 - CARACTERISTICAS TECNICAS DEL HARDWARE SERVIDOR SCADA
OBJETO El presente pliego de especificaciones técnicas tiene por objeto la adquisición de servidores para rack tipo mid-range según los detalles de hardware descriptos en este documento, licencias de software
Más detallesAplicaciones redundantes mediante el uso de software de Alta Disponibilidad y Tolerancia a Fallos everrun
Aplicaciones redundantes mediante el uso de software de Alta Disponibilidad y Tolerancia a Fallos everrun El diseño y la implementación de aplicaciones redundantes en entornos de industria e infraestructuras
Más detallesVelocidad más rápida de las redes
Tarjeta de Red Ethernet PCI Express de 10 Gigabits de Fibra con SFP+ abierto - Adaptador NIC StarTech ID: PEX10000SFP La tarjeta de red para fibra óptica a 10 Gigabits, modelo PEX10000SFP, es una solución
Más detallesAMD G-Series: Soluciones para Gaming o aplicaciones con gráficos intensivos (Digital Signage, etc.)
AMD G-Series: Soluciones para Gaming o aplicaciones con gráficos intensivos (Digital Signage, etc.) 1 AMD G-Series AMD Embedded G-Series: Nueva plataforma industrial de AMD que integra una CPU de bajo
Más detallesSoluciones innovadoras para optimizar su infraestructura TI. Virtualización con el sistema operativo i, PowerVM y Power Systems de IBM
Soluciones innovadoras para optimizar su infraestructura TI Virtualización con el sistema operativo i, PowerVM y Power Systems de IBM Características principales Tenga éxito en su negocio simplemente con
Más detallesDESCUBRE LA HIPERCONVERGENCIA A GRAN ESCALA CON VCE VXRACK
DESCUBRE LA HIPERCONVERGENCIA A GRAN ESCALA CON VCE VXRACK Javier Fernández de Benito VCE Senior varchitect EL MERCADO DE CI SE TRIPLICARÁ EN 4 AÑOS GASTO EN INFRAESTRUCTURA CONVERGENTE POR CATEGORÍAS
Más detallesL P N N o. B C 0 1-2013- S
L P N N o. B C 0 1-2013- S C O N T R A T A C I Ó N D E S E R V I C I O S D E C O N S U L T O R Í A P A R A U P G R A D E Y M I G R A C I Ó N D E O R A C L E E B U S I N E S S S U I T E A V. 1 2 CUADRO
Más detallesEXPEDIENTE: 2/2015 ADQUISICIÓN E INSTALACIÓN DE INFRAESTRUCTURA CIENTÍFICA Y TECNOLÓGICA PARA CÉNITS PLIEGO DE PRESCRIPCIONES TÉCNICAS
EXPEDIENTE: 2/2015 ADQUISICIÓN E INSTALACIÓN DE INFRAESTRUCTURA CIENTÍFICA Y TECNOLÓGICA PARA CÉNITS PLIEGO DE PRESCRIPCIONES TÉCNICAS PLIEGO DE PRESCRIPCIONES TÉCNICAS. EXPTE 2/2015 Adquisición e instalación
Más detallesRegulación. Presiones de Negocio. Retos Operativos
UNITRONICS UCS. LA AUTOMATIZACIÓN EN EL DATACENTER Situación actual Incertidumbre económica Globalización Regulación Dinámica competitiva Casos de uso creativos Presiones de Negocio Retos Operativos Restricciones
Más detallesUna opción convergente
vforum 2015 - vsan Una opción convergente Nombre Cargo mail@st.cl Fono 372 3200 372 32## Posicionamiento Características Arquitectura Mercado 2 VFORUM 2015: VSAN POSICIONAMIENTO 3 Porqué VSAN? La arquitectura
Más detallesNuevas plataformas de HP para entornos de hosting
Nuevas plataformas de HP para entornos de hosting Madrid 23 de Abril de 2009 Oscar Martínez Jefe de producto división de servidores estándares HP Española 2008 Hewlett-Packard Development Company, L.P.
Más detallesEl buque insignia del segmento de la gama media. Servidor MAXDATA PLATINUM 5220 I
El buque insignia del segmento de la gama media Servidor MAXDATA PLATINUM 5220 I Servidor MAXDATA PLATINUM 5220 I: El buque insignia del segmento de la gama media La configuración estándar El servidor
Más detallesSistema profesional de almacenamiento básico MAXDATA PLATINUM 600 IR
Sistema profesional de almacenamiento básico MAXDATA PLATINUM 600 IR MAXDATA PLATINUM 600 IR: Sistema profesional de almacenamiento básico Características del producto El servidor NAS (Network Attached
Más detallesAnexo Especificaciones Técnicas
Anexo Especificaciones Técnicas 1. OBJETO DEL CONCURSO: Equipamiento para Centro de Cómputos El llamado se realiza en el marco de la implantación del nuevo Centro de Cómputos del Plan Ceibal, con el objetivo
Más detallesHP Proliant Blades. Mario Pessini Consultor Preventa HP ISS
HP Proliant Blades Mario Pessini Consultor Preventa HP ISS La solución son infraestructuras mas eficientes Gesto (US$B) $300 $250 $200 Costes de alimentación y refrigeración Costes de gestión y adminitración
Más detallesEspecificaciones Técnicas para Equipos Servidores. Arquitectura basada en x86.
Especificaciones Técnicas para Equipos Servidores. Arquitectura basada en x86. Version 1.0 Deberá poseer setup residente en ROM, CD-ROM o DVD-ROM con password de ingreso y encendido. Deberá poseer control
Más detallesServidores blade. AGUILERA FERNANDO [Escribir el nombre de la compañía] 14/04/2011
2011 Servidores blade AGUILERA FERNANDO [Escribir el nombre de la compañía] 14/04/2011 SERVIDORES BLADE Definición.- Blade Server es una arquitectura que ha conseguido integrar en tarjetas todos los elementos
Más detallesÍTEM ELEMEN ESPECIFICACIONES
ÍTEM ELEMEN ESPECIFICACIONES CANTIDAD TO SERVIDORES DE RACK Actualmente, se cuenta con un servidor IBM POWER SYSTEM 520 EXPRESS SERVER MODEL E4A, PROC DUAL CORE DE 2,4GHZ, 6 GB RAM, 4 DD DE 300GB SAS R5,
Más detallesCENTRO DE DATOS BESTIAS DE CARGA: NUEVOS SERVIDORES DELL POWEREDGE EN RACK Y BLADE
ARTÍCULO: LA EMPRESA EFICIENTE CENTRO DE DATOS BESTIAS DE CARGA: NUEVOS SERVIDORES DELL POWEREDGE EN RACK Y BLADE La nueva undécima generación de servidores Dell PowerEdge en rack y blade está diseñada
Más detallesEspecificaciones detalladas
Hewlett Packard HP ProLiant ML110 G5 Servidor micro torre 4U 1 vía 1 x Dual Core Xeon 3065 / 2.33 GHz RAM 1 GB disco duro 1 x 250 GB DVD±RW (+R doble capa) Gigabit Ethernet Monitor : ninguno El servidor
Más detallesServidores Dell PowerEdge Guía de gama
Servidores Dell PowerEdge Guía de gama Servidores Dell PowerEdge Diseñado específicamente para la confiabilidad Habilitado para la virtualización a fin de ofrecer una infraestructura eficiente Administración
Más detallesApoyar a los Asociados de Negocios de IBM a rotar su inventario actual de productos run rate y de volumen.
IBM INCENTIVO ESPECIAL LA514-080 IBM System x - Promoción de Rotación de Stock en SSA y México! (Vence 30 de Septiembre de 2014) PROPUESTA DE VALOR Apoyar a los Asociados de Negocios de IBM a rotar su
Más detallesArquitectura de el Hp Superdome INTEGRANTES: Islas Islas Roberto A. Ortiz Flores Enrique A. Rico Vázquez Alejandro. Sistemas Operativos Avanzados
Arquitectura de el Hp Superdome INTEGRANTES: Islas Islas Roberto A. Ortiz Flores Enrique A. Rico Vázquez Alejandro Sistemas Operativos Avanzados HP SUPERDOME 9000 Características generales: El superdomo
Más detallesFSP:GA4S20ZPOESY12 FSP:GA4S20ZPOESY12 FSP:GA5S20Z00ESY12 FSP:GA5S20Z00ESY12 LBY:ESD-INS002PX1 299 LBY:ESD-INS002PX1 299. Fuente. Fuente de Redundante
Modelo PRIMERGY TX100 S3p PRIMERGY TX100 S3 PRIMERGY TX100 S3p PRIMERGY TX140 S1 PRIMERGY TX140 S1p PRIMERGY TX140 S1p NUEVO NUEVO NUEVO NUEVO Código VFY:T1003SC100IN VFY:T1003SC020IN VFY:T1003SC070IN
Más detallesPROYECTO DE VIRTUALIZACIÓN BLADE SYSTEM + VMWARE Business Case Empresa de Moda. Main Memory, S.A. Datos de contacto
PROYECTO DE VIRTUALIZACIÓN BLADE SYSTEM + VMWARE Business Case Empresa de Moda Main Memory, S.A. Datos de contacto e-mail: marketing@mainmemory.es Telf: 932139698 C/ Ramis 16, baixos Fax: 932139728 08012
Más detallesMayor seguridad, rendimiento y escalabilidad. Servidor MAXDATA PLATINUM 520
Mayor seguridad, rendimiento y escalabilidad Servidor MAXDATA PLATINUM 520 Servidor MAXDATA PLATINUM 520: Mayor seguridad, rendimiento y escalabilidad La configuración estándar El sistema MAXDATA PLATINUM
Más detallesINVITACIÓN ABIERTA A PRESENTAR OFERTAS PARA EL LA ADQUISICION DE EQUIPOS DE COMPUTO, SOFTWARE Y PERIFÉRICOS PARA ALMAGRARIO S.A. No.
INVITACIÓN ABIERTA A PRESENTAR OFERTAS PARA EL LA ADQUISICION DE EQUIPOS DE COMPUTO, SOFTWARE Y PERIFÉRICOS PARA ALMAGRARIO S.A. No. 020 DE 2011 ADENDA No. 1 ALMACENES GENERALES DE DEPOSITO ALMAGRARIO
Más detallesServidores HP Grupo CVA Gira de Negocios 2011. Miguel Aranda Gerente de Marca HP Servidores
Servidores HP Grupo CVA Gira de Negocios 2011 Miguel Aranda Gerente de Marca HP Servidores HP Servidores y Almacenamiento (EB) Unidades de cinta (Tape) Storage Array y NAS Infraestructura de SAN, SW HP
Más detallesEstándares Índice Estándares de Hardware Estándares para la adquisición de Equipos
Estándares Índice Estándares de Hardware 2 Estándares para la adquisición de Equipos 3 CPU Servidor de Aplicaciones de Cliente Fino 3 CPU Servidor de Archivos para Cliente Fino 4 PC Cliente Fino 5 PC Linux
Más detallesPLIEGO DE PRESCRIPCIONES TÉCNICAS PARA LA AMPLIACIÓN DE LA INFRAESTRUCTURA DE SERVIDORES Y ALMACENAMIENTO.
PLIEGO DE PRESCRIPCIONES TÉCNICAS PARA LA AMPLIACIÓN DE LA INFRAESTRUCTURA DE SERVIDORES Y ALMACENAMIENTO. A) OBJETO DEL CONTRATO. El objeto del presente contrato es la adquisición del equipamiento informático
Más detallesPuntos destacados. Vista frontal y trasera de la caja
Puntos destacados La potencia de dos núcleos Los procesadores dual core aúnan dos núcleos de procesador en un solo chip. En el ámbito de los servidores, hace años que existen aplicaciones compatibles con
Más detallesCaracterísticas del sistema
Características del sistema Sistema operativo Windows 8.1 Pro 64 Windows 8.1 de único idioma de 64 Windows 8.1 de único idioma de 64 Windows 7 Professional 64 (disponible mediante derechos de actualización
Más detallesEl Corazón de los Centros de Datos Flexibles y Eficientes
El Corazón de los Centros de Datos Flexibles y Eficientes Descubra la familia de procesadores Intel Xeon E5 80% Incremento de rendimiento 1 Innovación revolucionaria en E/S Alta Seguridad Excelente eficiencia
Más detallesServidores Dell PowerEdge Guía de la gama
Servidores Dell PowerEdge Guía de la gama Servidores Dell PowerEdge Especialmente diseñado para obtener fiabilidad Apto para virtualización para una infraestructura eficiente Gestión inteligente de sistemas
Más detallesServidores de Red Genéricos Arquitectura basada en X86 CODIGO ETAP: SR-001
CARACTERÍSTICAS GENERALES de Red Genéricos Arquitectura basada en X86 CODIGO ETAP: SR-001 Se incluyen las Consideraciones Especiales para servidores definidas en CESP-001, CESP- 002, CESP-005, y de corresponder
Más detallesDell R220 PowerEdge, Intel Xeon E3-1220V3 3.10GHz, 16GB DDR3, 2TB (2x 1TB), 3.5'', 1U - no Sistema Operativo Instalado
Dell R220 PowerEdge, Intel Xeon E3-1220V3 3.10GHz, 16GB DDR3, 2TB (2x 1TB), 3.5'', 1U - no stema Operativo Instalado DELL (0) SKU: 16801228 EAN: 0884116207498 Principales características: Tipo de chasis:
Más detallesPlataforma de 2 procesadores para nuevos usuarios. MAXDATA PLATINUM Server 500 I
Plataforma de 2 procesadores para nuevos usuarios MAXDATA PLATINUM Server 500 I Servidor MAXDATA PLATINUM 500 I Plataforma de 2 procesadores para nuevos usuarios Configuración estándar El MAXDATA PLATINUM
Más detallesTIC Forum Todo lo que necesita para llevar a su empresa a lo más alto. 26 de octubre de 2011. Buenos Aires, Argentina
TIC Forum Todo lo que necesita para llevar a su empresa a lo más alto 26 de octubre de 2011. Buenos Aires, Argentina Fabián Dominguez fdomingu@cisco.com 2011 Cisco and/or its affiliates. All rights reserved.
Más detallesMemoria de las mejoras, tanto técnicas y de plazos de entrega como de mantenimiento, que la empresa haya decidido ofrecer.
PLIEGO DE CLÁUSULAS TÉCNICAS PARA LA ADJUDICACIÓN DEL CONTRATO DE SUMINISTRO, INSTALACIÓN Y PUESTA EN MARCHA DE LA AMPLIACIÓN DE UN CLUSTER HPC PARA EL INSTITUT DE RECERCA BIOMÈDICA CLUSTER HPC Contratación
Más detallesVirginia Miguez Directora Administración Pública Intel Corporation Iberia virginia.miguez@intel.com
Virginia Miguez Directora Administración Pública Intel Corporation Iberia virginia.miguez@intel.com 1 Eficiencia en el Centro de Datos = Servicios de TI entregados Recursos necesarios (energía, enfriamiento,
Más detallesVersion 3. Capítulo 9. Fundamentos de hardware avanzado para servidores
Capítulo 9 Fundamentos de hardware avanzado para servidores Servidores para redes Un servidor es un computador en una red que es compartido por múltiples usuarios. El término servidor se refiere al hardware
Más detalles2.- CARACTERÍSTICAS TÉCNICAS DEL SUMINISTRO: Las características técnicas del suministro serán las siguientes:
PLIEGO DE PRESCRIPCIONES TÉCNICAS DEL SUMINISTRO PARA MEJORA DE INFRAESTRUCTURA INFORMATICA DEL CENTRO DE PROCESO DE DATOS (CPD) DE LA AUDIENCIA DE CUENTAS DE CANARIAS MEDIANTE PROCEDIMIENTO NEGOCIADO
Más detallesIntelligent Management Center
SOFTWARE DE ADMINISTRACION Intelligent Management Center HP intelligent Management Center o IMC, es una plataforma de administracion de interfaz Grafica, es una plataforma comprensiva que entrega capacidades
Más detallesEQUIPAMIENTO DE INFRAESTRUCTURA SERVIDORES PARA ACTIVA MUTUA Febrero 2011, Revisión: 1.1 PLIEGO DE CONDICIONES TÉCNICAS
EQUIPAMIENTO DE INFRAESTRUCTURA SERVIDORES PARA ACTIVA MUTUA Febrero 2011, Revisión: 1.1 PLIEGO DE CONDICIONES TÉCNICAS ÍNDICE 1. CONSIDERACIONES GENERALES... 1 1.1. OBJETO DEL CONTRATO... 1 1.2. PROPÓSITO
Más detallesPráctica tarjeta de combinación y solución que ahorra dinero
Tarjeta Adaptador de Red Ethernet Gigabit Combo con Hub Concentrador USB 3.0 de 3 Puertos StarTech ID: PEXUSB3S3GE Esta tarjeta PCIe USB 3.0 se acopla a sus conexiones de periféricos y de red como una
Más detallesADENDO 03. Mediante el presente adendo se realizan las siguientes modificaciones al Pliego de Condiciones de la Licitación:
VICERRECTORIA ADMINISTRATIVA SECCIÓN COMPRAS Y ADMINISTRACIÓN DE BIENES LICITACION PÚBLICA 02-200 ADQUISICION DE UNA SOLUCION PARA CONSOLIDACION Y VIRTUALIZACION DE SERVIDORES FASE II Y ADQUISICION DEL
Más detallesUNIVERSIDAD MILITAR NUEVA GRANADA INVITACIÓN PÚBLICA No. ANEXO 09 REQUERIMIENTOS TÉCNICOS DE LA SOLUCIÓN DE SERVIDORES
1 REQUERIMIENTOS TÉCNICOS DE LA Adquirir una plataforma de servidores capaz de sostener todos los servicios actualmente en funcionamiento en la Universidad, los servidores a ser adquiridos se catalogan
Más detallesPLIEGO DE PRESCRIPCIONES TÉCNICAS ESPECIFICACIÓN TÉCNICA DE CONTRATACIÓN EQUIPOS OFIMÁTICA 2012
PLIEGO DE PRESCRIPCIONES TÉCNICAS ESPECIFICACIÓN TÉCNICA DE CONTRATACIÓN EQUIPOS OFIMÁTICA Tecnologías de la Información 1/9 0.- INTRODUCCIÓN NAVANTIA S.A. está interesada en la realización de un Acuerdo
Más detallesRendimiento y coste de funcionamiento en perfecto equilibrio: Servidor MAXDATA PLATINUM con procesadores Dual-Core Intel Xeon
Rendimiento y coste de funcionamiento en perfecto equilibrio: Servidor MAXDATA PLATINUM con procesadores Dual-Core Intel Xeon Rendimiento y coste de funcionamiento en perfecto equilibrio: Servidor MAXDATA
Más detallesCaja Carcasa de Aluminio USB 3.0 de Disco Duro HDD SATA 3 III 6Gbps de 2,5 Pulgadas Externo con UASP
Caja Carcasa de Aluminio USB 3.0 de Disco Duro HDD SATA 3 III 6Gbps de 2,5 Pulgadas Externo con UASP StarTech ID: S2510BMU33 La caja de disco duro USB 3.0 con UASP, modelo S2510BMU33, le permite conectar
Más detallesCONCURSO COES N 05 / 2014
CONCURSO COES N 05 / 2014 RESPUESTAS A LAS CONSULTAS DE LOS POSTORES: ARRENDAMIENTO DE HARDWARE PARA LA BASE DE DATOS ORACLE DEL COES N Referencia Consultas respuesta 01 Punto: 1.5.4 Contenido de la Propuesta
Más detallesServidores HP ProLiant ML
Servidores HP ProLiant ML HP ofrece una línea completa de servidores específicamente optimizada para la expansión del sistema interno. Más allá del rendimiento, disponibilidad y calidad del producto tradicionales
Más detallesCompleta tu servidor con Sistema Operativo Microsoft :
Modelo PRIMERGY TX100 S2 PRIMERGY TX100 S2 PRIMERGY TX140 S1 PRIMERGY TX140 S1 Soporta RAID 5/6 100 de descuento* Código VFY:T1001SX480IN VFY:T1002SX030IN VFY:TX1401SC010IN VFY:TX1401SC020IN Procesadores
Más detallesTarjeta Adaptadora Controladora PCI Express PCI-E SATA 3 III 6Gbps RAID 4 Puertos con HyperDuo
Tarjeta Adaptadora Controladora PCI Express PCI-E SATA 3 III 6Gbps RAID 4 Puertos con HyperDuo StarTech ID: PEXSAT34RH La tarjeta controladora PCI Express 2.0 SATA de 4 puertos, con HyperDuo, modelo PEXSAT34RH,
Más detallesotra versión: rev. 1.1 Intel B75 Chipset
http://es.gigabyte.com/products/page/mb/ga-b75m-d3hrev_10 Página 1 de 3 Home Acceso Club España (Elije otro país) Enviar consulta Acerca de GIGABYTE»» Productos»» Comprar Medios de comunicación»» Inicio
Más detalles2. OBJETIVOS Y CARACTERÍSTICAS GENERALES DE LA INFRAESTRUCTURA
Contratación de infraestructura para la instalación del Centro de Procesamiento y Almacenamiento de Datos del Centro Internacional de Tecnologías Avanzadas en Peñaranda de Bracamonte (Salamanca) Condiciones
Más detallesFSP:GA4S20Z00ESPY1 4 años in situ NBD 187 FSP:GA5S20Z00ESPY1 5 años in situ NBD 239. Fuente Redundante opcional. Con Discos incluidos
PRODUCTO ESTRELLA Promociones válidas del 1 al 31 de octubre o fin de stock. Promociones no acumulables a otras ofertas o promociones. Precios de venta al público recomendados. IVA no incluido. Canon digital
Más detallesRedes de Altas Prestaciones
Redes de Altas Prestaciones TEMA 3 Tecnologías Soporte tolerante a fallos -Curso 2010 Redes de Altas Prestaciones - Indice Conceptos Topología en Alta Disponibilidad Tecnologías disponibles Tecnología
Más detallesLENOVO THINKSERVER GUÍA DE LA GAMA DE PRODUCTOS. Gran capacidad de ampliación y flexibilidad para crecer con su negocio.
LENOVO THINKSERVER GUÍA DE LA GAMA DE PRODUCTOS Gran capacidad de ampliación y flexibilidad para crecer con su negocio. Aumente la productividad, maximice la eficiencia y garantice la continuidad del negocio
Más detallesCaracterísticas. Aplicaciones
Características Controladora RAID S-ATA La controladora Intel Embedded Server RAID del equipo MAXDATA PLATINUM 100 I ofrece la posibilidad de crear una unidad lógica a partir de varias unidades físicas
Más detallesADENDA 01 AL PLIEGO DE CONDICIONES DE LA LICITACIÓN LICITACION PUBLICA No. 019 DE 2010
ADENDA 01 AL PLIEGO DE CONDICIONES DE LA LICITACIÓN LICITACION PUBLICA No. 019 DE 2010 CUYO OBJETO TIENE CONTRATAR LA COMPRA DE EQUIPOS (SERVIDORES BLADE Y WORKSTATION) CON DESTINO AL PROYECTO APROVECHAMIENTO
Más detallesPrecio cerrado para lo requerido en las condiciones técnicas.
EXPEDIENTE: SAG 20140006 (Errata 20140005) CUADRO DE CARACTERÍSTICAS DEL PLIEGO DE CLÁUSULAS ADMINISTRATIVAS PARTICULARES PARA LA CONTRATACIÓN, POR PROCEDIMIENTO ORDINARIO DE PROVEEDOR PARA EL SUMINISTRO
Más detallesSECRETARÍA DE HACIENDA Y ECONOMÍA DIRECCIÓN EJECUTIVA DE RACIONALIZACIÓN ADMINISTRATIVA. Año del bicentenario de la Revolución de Mayo
SECRETARÍA DE HACIENDA Y ECONOMÍA DIRECCIÓN EJECUTIVA DE RACIONALIZACIÓN ADMINISTRATIVA Año del bicentenario de la Revolución de Mayo Switch Layer 2. CARACTERISTICAS. ESPECIFICACIONES TECNICAS Puertos:
Más detalles1.5.3 INTERFACES POR SERVIDOR OCHO (8) INTERFACES MULTIFUNCIÓN CON SOPORTE PARA iscsi 1.6.1 CONECTIVIDAD FIBRE CHANNEL HBA DUAL PORT
FICHA TÉCNICA CARACTERÍSTICAS TÉCNICAS DE LOS PRODUCTOS Y SERVICIOS. En desarrollo del objeto mencionado, el proponente se compromete a suministrar, los equipos requeridos con las características técnicas
Más detallesLa Transformación del Data Center. Miguel Angel Ruiz Consulting Systems Engineer mruizhor@cisco.com
La Transformación del Data Center Miguel Angel Ruiz Consulting Systems Engineer mruizhor@cisco.com Presentation_ID 2009 Cisco Systems, Inc. All rights reserved. 1 Agenda Retos y Tendencias Estrategia Data
Más detallesEstación de Conexión con Ventilador USB 3.0 UASP 2 Bahías Disco Duro SATA 2,5" y 3,5" Hub USB - Negro
Estación de Conexión con Ventilador USB 3.0 UASP 2 Bahías Disco Duro SATA 2,5" y 3,5" Hub USB - Negro StarTech ID: SDOCK2U33HFB La estación de conexión (docking station) USB 3.0 para dos discos duros con
Más detalles