Procesador TSX P

Documentos relacionados
ZB5AP6S cabeza de pulsador - Ø 22 - azul - protegido

ZB5AS944 cabeza seta de emergencia emergencia Ø 40 - liberación de llave - Ø 22 - rojo

ZB4BJ8 cabeza selector selector -3 posiciones - Ø 22 - negro

Modicon M340. Adaptador periférico de E/S remotas BMX PRA 0100 Manual de usuario 07/ EIO

PMD 2/6 BASES MODULARES DOMÉSTICAS PARA FUSIBLES CILÍNDRICOS DOMESTIC MODULAR FUSE HOLDERS FOR CYLINDRICAL FUSE LINKS

SEÑALIZADORES SQ A A A B CONFIGURACIÓN Y DESCRIPCIÓN

TK Series IP66 Empty Enclosures More than 400 standard enclosures are available

OTB1E0DM9LP módulo distribuido E/S OTB - TCP/IP Ethernet m

Art Caja Final Carrera con Detector Inductivo

Tipo Electroválvulas

Contenido. Código: MLC510R14-450H/A Receptor de la cortina óptica de seguridad

Electrónica bus de campo y E/S

INTERNATIONAL BORDER SUPPLY S DE RL DE CV

Micro regulador proporcional electrónico Serie K8P

Contenido. Código: LS5/XX-M8 Emisor de fotocélula de barrera

Bienvenido al módulo de formación sobre la instalación de los convertidores de frecuencia ABB para maquinaria general ACS355.

NH-ST 2/16 BASES INDUSTRIALES NH-ST PARA FUSIBLES NH INDUSTRIAL NH-ST FUSE BASES FOR NH FUSE LINKS. Bases portafusibles para fusibles de cuchilla (NH)

FLUIDAL, S.L Fax LÍNEA SANITARIA SANITARY LINE LÍNEA SANITARIA / SANITARY LINE

LÍNEA SANITARIA SANITARY LINE LÍNEA SANITARIA / SANITARY LINE. Polígono Indutrial O Rebullón s/n Mos - España -

Termostato electrónico ETS 3000

Filtros footprint para convertidores Footprint filters for LSIS inverters

Contenido. Código: MLC500T14-900/A Emisor de la cortina óptica de seguridad

Conmutador Switch KVM para 4 Computadoras y 2 Pantallas DVI VGA Audio Puertos USB x1440

Unidades de mando y de señalización Harmony style 4 Pulsadores con embellecedor metálico cromado 22 Productos completos XB4-B.

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module

Sistema de estaciones de mando Serie ConSig 8040

Montaje. Vista frontal. LED amarillo: Salida relé I. LED amarillo: Salida relé II. Potenciómetro Histéresis relé I. Potenciómetro Histéresis relé II

Switch Conmutador KVM de 2 Puertos DVI VGA para 2 Monitores con USB y Audio

Ø 28 mm Ø 22 mm 2 mm 3 mm

Vea instrucciones para descargarse e instalar la última versión disponible del software de configuración LinkBoxMB y el manual de usuario en

Miniature Circuit Breakers Type GMB63

ORTRAT, S.L. DESCRIPCIÓN DE EQUIPOS SISTEMA DE INTERFONÍA CONTROL + SISTEMAS ORTRAT S.L. SISTEMA DE INTERFONÍA

2011 Honda CR-Z

Scion IQ 2012-up

LIGHT. Cajas estancas de derivación IP65-IP67. Datos técnicos. Certificaciones

Designación Tipo de contacto Marcado Color del pulsador. Rasante 1 I (blanco) Rasante 1 (negro) Designación Tipo de contacto Grado de protección

CAPITULO IV 4 IMPLEMENTACION DEL SISTEMA DE MONITOREO

Contenido. Código: CML720i-T A-M12-EX Emisor de la cortina óptica

VALVAC. Valvac System, S.L. Caja Finales de Carrera para Válvulas y Actuadores Neumáticos Limit Switch Box for Pneumatic Actuators and Valves

Vea instrucciones para descargarse e instalar la última versión disponible del software de configuración LinkBoxEIB y el manual de usuario en

Productos de Mando y Señalización

N0524/N1024, N POS/N POS

Kit de Switch Conmutador KVM de 2 Puertos DVI con USB Audio y Cables

Consola de Rack 1U con LCD de 17 Pulgadas HD 1080p y Concentrador Hub USB Frontal

Electroválvula de 3/2 y 4/2 vías para sistemas neumáticos

ABE7B20MRM20 Subbase activa ECO para CPU TWIDO

Con pantalla digital Alta precisión, fácil de usar

Distribuidor en Chile

BAT/ Regenera los vapores en líquido - Altura adaptable - Conexión Push-in. BAT/ Kit 24V. BAT/ Kit 36 V. BAT/ Kit 48 V

Kit extensor de red Ethernet VDSL2 a través de cable de par simple - 10/100Mbps - Alcance de 1,5km

Contenido. Código: CSL710-R A/L-M12 Receptor de la cortina óptica

Contenido. Código: CSL710-R A/L-M12 Receptor de la cortina óptica

ATFLASH. Sensor MANUAL DE USUARIO ATFLASH. Sensor MANUAL DE USUARIO ATFLASH SENSOR

Serie LI Rango 20A Esquema General

Automatización de una Célula de. Fabricación Flexible:

ARTICULO: L Actuador Eléctrico Rotativo GE Multivoltage GE Multivoltage Electric Rotary Actuator

Vea instrucciones para descargarse e instalar la última versión disponible del software de configuración LinkBoxEIB y el manual de usuario en

Carcasa industrial estándar de Ø2,5" Hasta 5000 impulsos Servobrida o brida cuadrada 10 V V con interface RS 422

Conmutador Switch KVM 4 puertos Vídeo DisplayPort DP Hub Concentrador USB 2.0 Audio x1600

Catálogo/tarifa de cuadros eléctricos OM. Sistema funcional de cuadros eléctricos metálicos hasta 630 A para aparamenta Hyundai.

USER MANUAL / MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA CUIDADOSAMENTE LAS INSTRUCCIONES ANTES DE USAR

SECCIÓN TABLEROS ELECTRICOS

Código: MSI Control de seguridad Contenido

DUAL SDL P&P REF: HI / /15

Vea instrucciones para descargarse e instalar la última versión disponible del software de configuración LinkBoxMB y el manual de usuario en

03/11/2015

ARTICULO: L Actuador Eléctrico Reversible GE Multivoltage GE Multivoltage Reversible Electric Actuator

Armario Rack 8U de Servidores para Montaje en Pared - con Profundidad de 30 Pulgadas - Rack de Pared

Conmutador Switch KVM para 4 Computadoras y 2 Pantallas DVI VGA Audio Puertos USB x1440

Art.5986 Caja Final Carrera con microelectromecánico. Art.59-- Caja Final Carrera con Detector Inductivo

Instrucciones de uso. CONTROLLER e AS-i AC1308/AC / / 2004

Conmutador Switch KVM de 2 Computadoras y 4 Pantallas DVI VGA con Audio 4 Puertos USB 2560x1600

Kits disponibles para el montaje de la central de incendios en un rack de 19 pulgadas. El rack debe pedirse por separado.

ART. 5803MT: Actuador Eléctrico Rotatorios GE Multivoltage ART. 5803MT: Electric Rotary Actuator GE Multivoltage

Conmutador Switch KVM de 2 Puertos Doble Monitor DVI VGA Audio 4 Puertos USB 1920x1200

Material de contactos AgNi, apto para cargas resistivas, poco inductivas y cargas de motor fluorescentes compactas (CFL) W

Switch Conmutador KVM de 4 Puertos DVI VGA con Audio y Hub USB 2.0 para Monitores Dobles

MANUAL DE INSTALACIÓN SUNRAIL PLANO. manual DE INSTALACIÓN SISTEMA SUNRAIL PLANO

IP 68 HEAVY DUTY ENCLOSURE

DESCRIPCIÓN DESCRIPTION FIGURA FIGURE

SENSORES CON CODIFICACIÓN MAGNÉTICA

Conversor de Vídeo VGA sobre red IP LAN - Extensor Hasta 100m - Ethernet LAN RJ45 USB x1080

Interfaces modulares de señalización e intervención A

Material de contactos AgNi, apto para cargas resistivas, poco inductivas y cargas de motor

HMIGTO6310 Terminal Táctil HMI 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

Material de contactos AgNi, apto para cargas resistivas, poco inductivas y cargas de motor

Directorio capítulo 07. Sub-D C Gama de Carcasas para conectores subminiatura D Página

ARTICULO: Actuador Eléctrico Monofásico Rotatorios GE - U0 unidireccional Monophasic Electric Rotary Actuator GE U0 unidirectional

juego para Profinet IO con grado de protección IP67 TI-BL67-EN-PN-6

Kia Sedona 2015-up B

Conmutador Switch KVM de 2 puertos con USB 2.0 Audio Video DisplayPort de 2 Monitores

Módulo de ampliación del bastidor BMX XBE 1000

Contenido. Código: MLC520R MG Receptor de la cortina óptica de seguridad

IdroBoX. novedades. IdroBoX PLus. Pulsador con porta etiqueta. Contenedor IP66 para tomas MÀTIX

SafeLine GL1. Instrucciones de funcionamiento. Opción de GSM para todos nuestros teléfonos de ascensor. (GSM-Line)

Consola KVM 1U con hub USB 2.0 y pantalla de 17 Pulgadas 1080p para rack

ABB i-bus KNX Actuador analógico, 2 canales, AP, 0-10 V AA/A 2.1.2, 2CDG110203R0011

CLIMATIZACIÓN ARMARIOS ELÉCTRICOS.

Concentrador Industrial USB 3.0 de 10 Puertos - Con protección de descargas

ABB i-bus KNX Interfaz USB, MDRC USB/S 1.1

Transcripción:

Procesador TSX P57 104 10 Características generales de los procesadores TSX P57 104 Procesadores TSX P57 104 La tabla siguiente muestra las características generales de los procesadores TSX P 57 104. Características TSX P57 104 Configuración máxima Funciones Número máximo de bastidores TSX RKY 12E 2 Número máximo de bastidores TSX RKY 4EX/6EX/8EX Número máximo de slots 27 Número máximo de canales Número máximo de conexiones E/S TON en bastidor 512 E/S analógicas en bastidor 24 Funciones específicas (conteo, eje...) Uni-Telway integrado (conector terminal) Red (ETHWAY, Fipway, Modbus Plus) Fipio maestro (integrado) - Bus de campo tercero - Bus de campo AS-i 2 Fechador que puede guardarse Memoria RAM interna que puede guardarse 96K8 Estructura de la aplicación Tarjeta de memoria PCMCIA (capacidad máxima) 224K8 Tarea MAST 1 Tarea FAST 1 Tratamientos tras sucesos (1 prioritario) 32 4 8 1 1 sí 147

Procesador TSX P57 104 Características TSX P57 104 Velocidad de ejecución del código de aplicación Tiempo de ejecución Sistema Overhead Ram interna 100% booleano 4,76 Kins/ms (1) Tarjeta PCMCIA 65% booleano + 35% digital 3,57 Kins/ms (1) 100% booleano 3,10 Kins/ms (1) 65% booleano + 35% digital 2,10 Kins/ms (1) Una instrucción booleana básica 0,19/0,25 s (2) Una instrucción digital básica 0,25/0,50 s (2) Una instrucción en flotantes 1,75/3,30 s (2) Tarea MAST Tarea FAST 1 ms 0.3 ms (1) Kins: 1024 instrucciones (lista) (2) El primer valor corresponde al tiempo de ejecución cuando la aplicación se encuentra en la RAM interna del procesador; el segundo valor corresponde al tiempo de ejecución cuando la aplicación se encuentra en una tarjeta PCMCIA. 148

Contact functions Harmony XB4 = + 2 Selector switches and key switches Type of head Plated circular bezel Degree of protection IP 66 / Nema 4X, 13 Mounting (mm) panel cut-out + 0.4 Ø 22.5 (22.4 0 recommended) mounting centers 30 (horizontal) x 40 (vertical) Depth (mm) below head 43 Connection (1) Screw clamp ter minals Type of operator Handle Products Complete For user assembly Complete For user assembly Number and type of positions 2 positions 2 positions 2 positions 2 positions stay put stay put spring retur n to left spring return to left Catalog number black N.O. XB4BD21 ZB4BZ101 ZB4BD2 XB4BD41 ZB4BZ101 ZB4BD4 Number and type of positions 3 positions 3 positions 3 positions 3 positions stay put stay put spring retur n to center spring return to center Catalog number black N.O. + N.O. XB4BD33 ZB4BZ103 ZB4BD3 XB4BD53 ZB4BZ103 ZB4BD5 = + Type of operator Key, n 455 Products Complete For user assembly Complete For user assembly Number and type of positions (2) 2 positions 2 positions 2 positions 2 positions stay put stay put stay put stay put Catalog number black N.O. XB4BG21 ZB4BZ101 ZB4BG2 XB4BG41 ZB4BZ101 ZB4BG4 Number and type of positions 2 positions 2 positions 3 positions 3 positions spring return to left spring return to left stay put stay put Catalog number black N.O. XB4BG61 ZB4BZ101 ZB4BG6 black N.O. + N.O. XB4BG33 ZB4BZ103 ZB4BG3 Separate components Electrical blocks Single contact blocks Rated operational characteristics AC-15, 240 V - 3 A Positive operation of contacts conforming to IEC/EN 60947-5-1 All functions incorporating a N.C. contact are positive opening operation Catalog number (5)* N.O. ZBE101 N.C. ZBE102 (1) Alter native connections: plug-in connector, Faston connectors (6.35 and 2 x 2.8). (2) The symbol indicates key withdrawal position. * sold in lots of For other versions, please consult with your Schneider Electric/ Square D sales office: visit www.us.telemecanique.com 2/13

Control stations For XB5 push buttons, switches and pilot lights Ø 22 mm with plastic bezel Harmony XB5/XAL (1): Number of cut-outs Number (p) 1 1 2 2 3 3 4 4 5 5 2 Complete stations with 1 push button, selector switch or key switch (light grey RAL 7035 base with dark grey RAL 7016 lid) Degree of protection IP 65 / Nema 4X and 13 Dimensions (mm) W x H x D 68 x 68 x 113 max. (with key release Ø 40 mushroom head push button) Fixing (mm) 2 x Ø 4.3 on 54 mm centers Function 1 Start or Stop function 1 Start-Stop function Marking On spring return push On legend holder and legend below head Number and type of push button/selector switch/key switch 1 flush green p/b 1 flush red p/b 1 projecting red p/b 1 2 position stay put selector switch or key switch Black handle Catalog number N.O. I XALD102 Start XALD103 O - I XALD134 XALD144 N.C. O XALD112 XALD115 Key n 455 (key withdrawal LH pos.) (1) Empty enclosures: Basic catalog number: XALK0p, replace the p by the number of cut-outs required (see cut-out table above) Function Emergency stop (2) (light grey RAL 7035 base with yellow RAL 1012 lid) Number and type of mushroom head push button 1 red Ø 40 head, turn to release 1 red Ø 40 head, key release Latching mechanism Trigger action (EN 418) Latching Latching Catalog number N.C. XALK174 XALK184 N.C. + N.C. XALK178F XALK174F XALK184F N.C. + N.O. XALK178E XALK174E XALK184E N.C. + N.C. + N.O. XALK178G XALK174G XALK184G (2) The mushroom head Emergency stop push buttons conform to standard IEC/EN 60947-5-5 and Machinery Directive 98/37/EC. Trigger action mushroom head push buttons confor m to standard EN 418. (1) Empty enclosures: Basic catalog nuber: XALK0p, replace the p by the number of cut-outs required (see cut-out table above) Complete stations with 2 and 3 push buttons or 2 push buttons + 1 pilot light (light grey RAL 7035 base with dark grey RAL 7016 lid) Dimensions (mm) W x H x D 2-way control stations: 68 x 106 x 62; 3-way control stations: 68 x 136 x 87 Fixing (mm) 2-way control stations: 2 x Ø 4.3 on 54 x 68 centers; 3-way control stations: 2 x Ø 4.3 on 54 x 98 centers Function Start-Stop functions 2 functions 3 functions Marking On spring return push Number and type of push button/pilot light 1 flush green p/b 1 flush green push button 1 flush white p/b 1 flush white p/b 1 flush white p/b 1 flush red p/b 1 flush red push button 1 flush black p/b 1 flush red p/b 1 Ø 30 red mush- 1 red pilot light with integral LED (1) room head p/b 24 VAC/DC 230 VAC Catalog number N.O. + N.C. I - O XALD213 XALD363B XALD363M Start - Stop XALD215 N.O. + N.O. XALD222 1 flush black p/b N.O. + N.C. + N.O. XALD324 XALD328 Accessories Standard contact blocks (1) Light blocks with integral LED, color red Description N.O. contact N.C. contact 24 VAC/DC 230 VAC Catalog number ZENL1111 ZENL1121 ZALVB4 ZALVM4 For other versions, please consult with your Schneider Electric/ Square D sales office: visit www.us.telemecanique.com 2/19

Racks estándar Permiten crear una estación del autómata limitada a un solo rack. En esta tabla se muestran los diferentes racks estándar: Designación TSX RKY 6 Ilustración rack de seis posiciones TSX RKY 8 rack de ocho posiciones TSX RKY 12 rack de 12 posiciones 367

Racks extensibles Permiten crear una estación del autómata que puede componerse de: Un máximo de ocho racks TSX RKY 12 EX, o un máximo de 16 racks TSX RKY 4EX/6EX/8EX. Estos racks se distribuyen en un bus llamado Bus X, cuya longitud máxima es de 100 metros. La continuidad del bus de un rack hacia otro rack se asegura mediante un cable de extensión del bus. Para aplicaciones que requieran una distancia mayor, el módulo de traslado del Bus X permite realizar, desde el rack que admite el procesador, la conexión de dos segmentos del Bus X a una distancia máxima de 250 metros. En esta tabla se muestran los diferentes racks extensibles: Designación TSX RKY 4EX Ilustración rack de cuatro posiciones TSX RKY 6EX rack de seis posiciones 368

Designación TSX RKY 8EX Ilustración rack de ocho posiciones TSX RKY 12EX rack de 12 posiciones 369

Rack estándar: descripción Presentación Permiten crear una estación del autómata limitada a un único rack. Ilustración Rack estándar 1 3 4 9 6 6 8 7 6 5 2 370

Descripción En la tabla siguiente se describen los distintos elementos de un rack estándar. Número Descripción 1 Chapa metálica que garantiza las funciones de: Soporte de la tarjeta electrónica Bus X y protección de ésta frente a los parásitos de tipo EMI y ESD, soporte de los módulos y rigidez mecánica del rack. 2 Ventanas destinadas al entintado de las pestañas del módulo. 3 Conectores hembra 1/2 DIN de 48 puntos que garantizan la conexión entre el rack y cada módulo. Durante la entrega del rack, estos conectores están protegidos por tapas que se deberán retirar antes de colocar los módulos. El conector situado en el extremo izquierdo e identificado como PS siempre está destinado al módulo de alimentación del rack; los conectores restantes se identifican de 00 a.. y están destinados a alojar todos los demás tipos de módulos. 4 Orificios de rosca para el tornillo de fijación del módulo. 5 Ventana que asegura la decodificación durante el montaje de un módulo de alimentación. Los módulos de alimentación están provistos de un saliente en la parte posterior, por lo que su montaje no se podrá realizar en ninguna otra posición. 6 Orificios para la fijación del rack en un soporte; permiten la fijación de tornillos M6. 7 Emplazamiento para indicación de la dirección del rack. 8 Emplazamiento para indicación de la dirección de red de la estación. 9 Bornes de tierra para la puesta a tierra del rack. 371

Rack extensible: descripción Presentación Permiten crear una estación del autómata que se puede componer de varios racks. Ilustración Rack extensible 1 3 4 10 8 5 6 9 6 11 7 6 2 372

Descripción En la siguiente tabla se describen los distintos elementos de un rack extensible. Número Descriptivo 1 Chapa metálica que garantiza las funciones de: Soporte de la tarjeta electrónica del Bus X y protección de ésta frente a los parásitos de tipo EMI y ESD, soporte de los módulos y rigidez mecánica del rack. 2 Ventanas destinadas al entintado de las pestañas del módulo. 3 Conectores hembra 1/2 DIN de 48 puntos que garantizan la conexión entre el rack y cada módulo. Durante la entrega del rack, estos conectores están protegidos por tapas que se deberán retirar antes de colocar los módulos. El conector situado en el extremo izquierdo e identificado como PS siempre está destinado al módulo de alimentación del rack; los conectores restantes se identifican de 00 a.. y están destinados a alojar todos los demás tipos de módulos. 4 Orificios de rosca para el tornillo de fijación del módulo. 5 Ventana que asegura la decodificación durante el montaje de un módulo de alimentación. Los módulos de alimentación están provistos de un saliente en la parte posterior, por lo que su montaje no se podrá realizar en ninguna otra posición. 6 Orificios para la fijación del rack en un soporte; permiten el paso de tornillos M6. 7 Emplazamiento para indicación de la dirección del rack. 8 Emplazamiento para indicación de la dirección de red de la estación. 9 Bornes de tierra para la puesta a tierra del rack. 10 Microinterruptor para codificar la dirección del rack (sólo en racks extensibles). 11 Conectores hembra SUBD de nueve puntos que permiten conectar el Bus X a otro rack (sólo a un rack extensible). 373

Racks estándar y extensibles TSX RKY.. : instalación/montaje Dimensiones de los racks: figuras Los dibujos siguientes muestran las dimensiones de los racks TSX RKY. TSX RKY 4EX 160 mm (1) 200 mm (2) 187,9 mm TSX RKY 6/6EX 165 mm (1) 151,5 mm 165 mm (1) 261,6 mm TSX RKY 8/8EX 335,3 mm TSX RKY 12/12EX 482,6 mm (1) Con módulos de bloque de terminales con tornillos. (2) Profundidad máxima con todos los tipos de módulos y sus conexiones asociadas. 378