Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes



Documentos relacionados
Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes

Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes

Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes

Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes

Osciloscopios de almacenamiento digital Serie TDS1000B Serie TDS2000B

Osciloscopios de Almacenamiento Digital

Osciloscopios de fósforo digital Digital Phosphor Oscilloscopes

Contenido. EA:Curso 2005 / 06 Osciloscopio OD581 2

CARACTERISTICAS. Fidel Oteiza #1921 Oficina 1106, Providencia, Santiago Fono: (2) Fax: (2)

Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes

OSCILOSCOPIOS MIXTOS SERIE DS1000

Generadores de funciones/arbitrarios Arbitrary/Function Generators

AVT 1648 DIGIGUARD. Compresión de MPEG 4 que brinda una imagen clara y un performance excelente en tiempo real. La transmisión es más rápida.

1.3

SDS7102 Osciloscopio digital OWON 100MHz 2 canales, pantalla TFT LCD color de 8 pulgadas Interfaz USB y LAN Salida de video SVGA PORTÁTIL: Con

- RS-232, Centronics, Ethernet yinterfaz USB - Pantalla a color táctil TFT LCD de

NEXUS 3001XLM-IMP Brinell hardness tester

Osciloscopios de Almacenamiento Digital Serie 2550

Hard Disk Drive Duplicator Dock USB 3.0 to SATA HDD Duplicator. StarTech ID: SATDOCK22RU3

OSCILOSCOPIO DIGITAL. GA1000CAL Series. Caracteristicas. Aplicaciones

USO DE OSCILOSCOPIO Y GENERADOR DE FUNCIONES

HYGROLOG HL-20 ± %RH / ±0.3 K C / %RH. Measuring range with. integrated probe. Power supply / Power

Osciloscopios de Almacenamiento Digital Folleto Técnico Serie TBS1000B-EDU

OD-590 OD-591 OD-592 OD-590 OD-591 OD-592 VERTICAL

OSCILOSCOPIO RIGOL DS1102E

ESCUELA UNIVERSITARIA POLITECNICA DE LA ALMUNIA DE DOÑA GODINA

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

LED Strobe Panel - Manual

Súper Link Adaptador USB 300H con doble antena de 5dBi USB 300H with 5dBi doublé antenna Adapter

ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

Osciloscopios de fósforo digital Digital Phosphor Oscilloscopes

FUSIBLES CILINDRICOS INDUSTRIALES am INDUSTRIAL CYLINDRICAL am FUSE-LINKS

Este adaptador también es compatible con la transferencia local de ficheros y la captura de vídeos integrados en el software.

CAPÍTULO 3 ANALIZADOR DE ESPECTROS ÓPTICO Y REQUERIMIENTOS DEL SISTEMA. 3.1 Descripción de funciones del Analizador de Espectros Óptico.

Conmutador Switch KVM para 4 Computadoras y 2 Pantallas DVI VGA Audio Puertos USB x1440


MANUAL DE INSTRUCCIONES DATALOGGER MICRATECH ET-175

Other Drives. Processor. More Information

Portable esata USB to SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: SATDUPUEGB

Software TRENDnetVIEW Pro. Guía de instalación rápida de TRENDnetVIEW Pro (1)

LABORATORIO DE CONTROL POR COMPUTADOR 4º - INGENIERIA DE TELECOMUNICACION

EP-2906 Manual de instalación

Conmutador Switch KVM IP Administración Remota 4 Puertos VGA Serie Serial USB 1920x1440

Quick Installation Guide TU2-DVIV H/W: V1.0R

Universidad de Guadalajara

ADQUISICIÓN Y GESTIÓN DE DATOS PARA LOS SISTEMAS ELECTROMECÁNICOS, MODELO 9062

UNIVERSIDAD DE IBAGUÉ INGENIERÍA ELECTRÓNICA MANUAL PRACTICO OSCILOSCOPIO DIGITAL HP 54600B

Osciloscopios de Almacenamiento Digital Portátiles Serie 2510

Extension Cords Extensiones Eléctricas We light your world

CESVA USB DRIVER. M_CUD_v0001_ _ESP_ENG

Creating your Single Sign-On Account for the PowerSchool Parent Portal

Sesión 3: PL 2b: Sistema para la adquisición de señales analógicas.

Osciloscopios de señal combinada Mixed Signal Oscilloscopes

PJD7822HDL. Overview. Full HD 1080p ofrece la mejor calidad de imagen. 2 x entradas HDMI

24-Port 10/100Mbps Web Smart PoE Switch with 4 Gigabit Ports and 2 Mini-GBIC Slots TPE-224WS

Save Money 2-up Single Doorhanger Set OH payday advance edition, 4 different doorhangers, Spanish

DISEÑO DE UN PLC DOMÉSTICO UTILIZANDO UN MICROCONTROLADOR PIC-18F4550

Touch Display Link - Nueva Solución de Software para Sharp IWB -

PCE Ibérica S.L. Mayor 53 Bajo Tobarra (Albacete) Tel: Fax:

Etiquetas electrónicas para fresco Toshiba

PRÁCTICA II: ADQUISICIÓN DE DATOS CON LABVIEW

Video Server. Quick Installation Guide. English, Español

GENERADORES DE FUNCIONES ARBITRARIOS MIXTOS

Schindler 7000 Planning parameters of high-rise elevators.

CS-1 Lector de Documentos y Sistema de Analisis Forense [All-In-one]

TERMINOLOGÍA Y MEDICIONES CON EL OSCILOSCOPIO

Caja Torre RAID Matriz Array de Discos Duros 4 Bahías SATA - esata USB 3.0 SuperSpeed

Guía de instalación rápida TFM-561U

Guía de instalación rápida TBW-107UB 1.01

Osciloscopio TDS 220 Tektronix

Los bloques DLL (Figura A.1) externos permiten al usuario escribir su propio código y

Guía de Productos. Para Instrumentación Virtual. ni.com/bajocosto/mx. Bajo costo Variedad de señales Resultados rápidos

Bienvenido...3 Instalar el hardware...4 Instalar el software...5 Iniciar el software...6 El Osciloscopia...7 El módulo analizador de espectro...

Aumente su productividad mediante el uso de varias pantallas. Splitter Multiplicador Mini DP a 2 puertos DisplayPort - Hub MST

USB 2.0 SERVIDOR ETHERNET DE IMPRESORA

Osciloscopios de señal combinada Mixed Signal Oscilloscopes

Caja Carcasa de Aluminio USB 3.0 de Disco Duro HDD SATA 3 III 6Gbps de 2,5 Pulgadas Externo con UASP

6.03" (15.30 cm) 22.02" (55.90 cm) 12.02" (30.50 cm) 50 to 104 deg F 10 to 40 deg C -40 to 158 deg F -40 to 70 deg C -40 to 158 deg F.

LAP MODULADOR QAM ANEXO A / B WT-3303

Instrumentación biomédica Prácticas de laboratorio

SC-T46. Overview. Cliente ligero

Steps to Understand Your Child s Behavior. Customizing the Flyer

8 Port VGA over Cat5 Digital Signage Broadcaster with RS232 & Audio

Osciloscopio portátil 100 MHz Modelos OX7102 III y OX7104 III

PCE Ibérica S.L. Mayor 53 Bajo Tobarra (Albacete) Tel: Fax:

GLOBAL QUALITY MANAGEMENT

Universidad de Pamplona Laboratorio de Electronica Digital Li211 y Control Li212. Manual de Funcionamiento Agilent Technologies dso322a

Manual de usuario de MITSUBISHI Photo Suite Impresora CPK60. Versión 1.1

GARAGE DOOR OPENER CONNECTIVITY HUB QUICK START GUIDE

La Carrera ya comenzo!! Manuel Ordóñez Gerente de Ventas México

Data Center Power Distribution Solution Provider

FACULTAD DE INGENIERÍA. Departamento de Electrónica. LABORATORIO Informática TRABAJO PRÁCTICO N 1. Multímetro en continua GRUPO N N PADRÓN

tema 2 - administración de proyectos escuela superior de ingeniería informática ingeniería del software de gestión

FUSIBLES CILÍNDRICOS MT PARA APLICACIONES DE ALUMBRADO MV CYLINDRICAL FUSE-LINKS FOR LIGHTING PURPOSES


Almacenamiento externo de gran capacidad y alto rendimiento

Adaptador Gráfico Externo Multimonitor USB 3.0 a VGA con Hub Concentrador USB de 3 Puertos x p

Portal para Padres CPS - Parent Portal. Walter L. Newberry Math & Science Academy Linda Foley-Acevedo, Principal Ed Collins, Asst.

Conmutador Switch KVM IP Administración Remota 8 Puertos VGA Serie Serial USB 1920x1440

Transcripción:

Osciloscopios de almacenamiento digital Digital Storage Oscilloscopes Hoja de datos de la serie TDS1000B / TDS1000B Series Data Sheet Aplicaciones Diseño y depuración Enseñanza y formación Prueba de fabricación y control de calidad Servicio y reparación * 1 Rigen determinadas limitaciones. Para obtener información acerca de los términos y las condiciones, visite www.tektronix.com/lifetimewarranty. Funciones y ventajas Anchos de banda de 40 MHz, 60 MHz y 100 MHz Frecuencias de muestreo de hasta 1 GS/s en tiempo real 2 canales Pantalla LCD monocromática Almacenamiento de datos extraíble por medio del puerto USB del panel frontal Conectividad perfecta con PC mediante el puerto de dispositivo USB con software PC OpenChoice y NI SignalExpress Disparadores avanzados que incluyen disparo de ancho de pulso y disparo de video de línea seleccionable FFT estándar en todos los modelos 12 mediciones automáticas Interfaz de usuario multilingüe y ayuda sensible al contexto Impresión directa en todas las impresoras compatibles con PictBridge por medio del puerto USB Garantía de por vida* 1

Data Sheet Almacene cómodamente en su unidad flash USB las capturas de pantalla y los datos de las formas de ondas. Osciloscopios de la serie TDS1000B Productivos de forma instantánea. Increíblemente sencillos. Los osciloscopios de almacenamiento digital de la serie TDS1000B ofrecen una combinación de rendimiento y facilidad de uso sin rival en el mercado, a un precio que está a su alcance. Precisión digital a un precio asequible Con un ancho de banda de hasta 100 MHz y una frecuencia de muestreo máxima de 1 GS/s, no existe otro osciloscopio de almacenamiento digital que ofrezca tanto ancho de banda y tanta frecuencia de muestreo por el mismo precio. Los osciloscopios de la serie TDS1000B proporcionan una adquisición precisa en tiempo real en todo su ancho de banda, la misma longitud de grabación en todas las configuraciones básicas de tiempo, disparadores avanzados para aislar las señales de interés y 12 mediciones automáticas estándar en todos los modelos. Sus funciones matemáticas de suma, resta y multiplicación de forma de onda, además de la Transformada rápida de Fourier (FFT), le permiten analizar, caracterizar y resolver los problemas de los circuitos. Captura de forma de onda rápida y sencilla Gracias a su sencilla interfaz de usuario, basada en controles clásicos de tipo analógico, estos instrumentos son fáciles de utilizar, por lo que se reduce el tiempo de aprendizaje y se incrementa la eficiencia. Funciones innovadoras, como el menú Autoconfiguración, el Asistente de comprobación de punta de prueba y el menú Ayuda sensible al contexto optimizan la configuración y el funcionamiento del instrumento. Capture, guarde y analice con gran facilidad los resultados de las mediciones con el software de comunicaciones para PC OpenChoice. Documentación y análisis sencillos Capture, guarde y analice con gran facilidad los resultados de las mediciones con el software de comunicaciones para PC OpenChoice. Simplemente tiene que exportar los datos de las imágenes de pantalla y las formas de onda a la aplicación de escritorio independiente o directamente a Microsoft Word y Excel. Como complemento para OpenChoice, el software National Instruments SignalExpress Tektronix Edition pone a su alcance funciones ampliadas, entre las que se incluyen el análisis avanzado, el control remoto del osciloscopio y el análisis de la forma de onda activa. O bien, si prefiere no utilizar la PC, puede imprimir su imagen directamente con cualquier impresora compatible con PictBridge por medio del puerto USB para dispositivos. Un rendimiento de confianza Con Tektronix tendrá la seguridad de un rendimiento en el que puede confiar. Además de su servicio y asistencia líderes en la industria, los osciloscopios de la serie TDS1000B incluyen la cobertura de Garantía de por vida* 1 como componente estándar. * 1 Rigen determinadas limitaciones. Para obtener información acerca de los términos y las condiciones, visite www.tektronix.com/lifetimewarranty. Transferencia flexible de datos Al disponer de puertos USB para host y para dispositivos que permiten almacenamiento de datos extraíble, perfecta conectividad a PC e impresión directa, no existe otro osciloscopio de almacenamiento digital que ofrezca tanta flexibilidad y facilidad de manejo por este precio. 2 www.tektronix.com

Digital Storage Oscilloscopes TDS1000B Series Characteristics TDS1000B Series Digital Storage Oscilloscopes Characteristic TDS1001B TDS1002B TDS1012B Display Mono (1/4 VGA LCD) Bandwidth* 2 40 MHz 60 MHz 100 MHz Channels 2 External Trigger Included on all models Input Sample Rate on 500 MS/s 1.0 GS/s 1.0 GS/s Each Channel Record Length 2.5K points at all time bases on all models Vertical Resolution 8 bits Vertical Sensitivity 2 mv to 5 V/div on all models with calibrated ne adjustment DC Vertical ±3% on all models Accuracy Vertical Zoom Vertically expand or compress a live or stopped waveform Maximum Input Voltage 300 V RMS CAT II; derated at 20 db/decade above 100 khz to 13 V p-p AC at 3 MHz Position Range 2 mv to 200 mv/div +2 V; >200 mv to 5 V/div +50 V Bandwidth Limit 20 MHz for all models Input Coupling AC, DC, GND on all models Input Impedance 1MΩ in parallel with 20 pf Time Base Range 5nsto50 s/div Time Base 50 ppm Accuracy Horizontal Zoom Horizontally expand or compress a liveor stopped waveform I/O Interfaces USB Ports GPIB Nonvolatile Storage Reference waveform display Waveform storage without Maximum USB ash drive size Waveform storage with Setups without Setups with USB ash drive Screen images with USB ash drive Save All with * 2 Bandwidth is 20 MHz at 2 mv/div, all models. USB host port on front panel supports s USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers al (2) 2.5K point reference waveforms (2) 2.5K point 64 GB 96 or more reference waveforms per 8 MB 10 front-panel setups 4000 or more front-panel setups per 8 MB 128 or more screen images per 8 MB (the number of images depends on le format selected) 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 les (setup, image, plus one le for each displayed waveform) Acquisition Modes Mode Peak Detect High-frequency andrandom-glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/divto50s/div Sample Sample data only Average Waveform averaged, selectable: 4, 16, 64, 128 Single Sequence Use the Single Sequence button to capture a single triggered acquisition sequence Roll At acquisition time base settings of >100 ms/div Trigger System Characteristic TriggerModes Trigger Types Trigger Edge (Rising/Falling) Video Pulse Width (or Glitch) Trigger Source CH1, CH2, Ext, Ext/5, AC Line. Auto, Normal, Single Sequence Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all elds from composite video, or broadcast standards (NTSC, PAL, SECAM) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s Trigger View Displays trigger signal while Trigger View button is depressed. Trigger Signal Frequency Readout Provides a frequency readout of the trigger source. Cursors Characteristic Types Measurements Amplitude, Time ΔT, 1/ΔT, ΔV Automatic Waveform Measurements Period, Frequency, +Width, Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS. Waveform Math Characteristic Operators FFT Sources Add, Subtract, Multiply, FFT Windows: Hanning, Flat Top, Rectangular; 2048 sample points CH1 CH2, CH2 CH1, CH1 + CH2, CH1 CH2 www.tektronix.com 3

Data Sheet Autoset Menu Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset. Signal Type Autoset Menu Choices Square Wave Single Cycle, Multicycle, Rising or Falling Edge Sine Wave Single Cycle, Multicycle, FFT Spectrum Video (NTSC, PAL, SECAM) Field: All, Odd, or Even Line: All or Selectable Line Number Autorange Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes. Display Characteristics Characteristic Display ¼ VGA backlit passive LCD with adjustable multilevel contrast and inverse video selectable from front panel Interpolation Sin (x)/x Display Types Dots, vectors Persistence Off,1s,2s,5s,in nite Format YT and XY Multiple-language User Interface and Context-sensitive Help Characteristic Languages Available * 3 Requires Russian rmware, indicated by "RUS" suf x. English, French, German, Italian, Japanese, Korean, Portuguese, Russian* 3, Simpli ed Chinese, Spanish, Traditional Chinese Environmental and Safety Characteristic Temperature Operating 0 to +50 ºC Nonoperating 40to+71ºC Humidity Operating and Up to 80% RH at or below +40 ºC Nonoperating Operating and Up to 45% RH up to +50 ºC Nonoperating Altitude Operating and Up to 3,000 m Nonoperating Electromagnetic Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Compatibility Australian EMC Framework Safety UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001 Physical Characteristics Instrument Dimensions mm in. Width 326.3 12.85 Height 158.0 6.22 Depth 124.2 4.89 Weight kg lb. Instrument Only 2.0 4.4 With accessories 2.2 4.9 Instrument Shipping Package Dimensions mm in. Width 476.2 18.75 Height 266.7 10.5 Depth 228.6 9.0 RM2000B Rackmount mm in. Width 482.6 19.0 Height 177.8 7.0 Depth 108.0 4.25 4 www.tektronix.com

Digital Storage Oscilloscopes TDS1000B Series Ordering Information Models Model TDS1001B TDS1002B TDS1012B Standard Accessories Accessory Passive Probes Power Cord NIM/NIST Documentation OpenChoice PC Communications Software National Instruments SignalExpress Tektronix Edition Interactive Measurement Software Base Version Limited Lifetime Warranty* 4 40 MHz, 2 Ch, 500 MS/s, Monochrome DSO 60 MHz, 2 Ch, 1 GS/s, Monochrome DSO 100 MHz, 2 Ch, 1 GS/s, Monochrome DSO 200 MHz (one per channel) (Please specify plug option) Traceable Certi cate of Calibration User manual (please specify preferred language option) Enables fast and easy communication between a Windows PC and the TDS1000B Series using USB. Transfer and save settings, waveforms, measurements, and screen images A fully interactive measurement software environment optimized for the TDS1000B Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using intuitive drag-and-drop user interface that does not require any programming. Standard TDS1000B Series support for acquiring, controlling, viewing, and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing, and user-de ned step capabilities. Order SIGEXPTE for permanent Professional Version capability Covers labor and parts for defects in materials and workmanship for a minimum of 10 years, excluding probes and accessories* 5 * 4 Lifetime is de ned as 5 years after Tektronix discontinues manufacturing the product, but the warranty length shall be at least 10 years from date of original purchase. Lifetime warranty is nontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty. * 5 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms. Power Plug s A0 North America power A1 Universal Euro power A2 United Kingdom power A3 Australia power A5 Switzerland power A6 Japan power A10 China power A11 India power A99 No power cord or AC adapter User Manual s Translated front-panel overlays included with their respective user manuals. L0 English manual L1 French manual L2 Italian manual L3 German manual L4 Spanish manual L5 Japanese manual L6 Portuguese manual L7 Simple Chinese manual L8 Standard Chinese manual L9 Korean manual L10 Russian manual Recommended Accessories Accessory TEK-USB-488 GPIB-to-USB Converter SIGEXPTE National Instruments SignalExpress Tektronix Edition Interactive Measurement Software Professional Version AC2100 Soft Carrying Case for instrument HCTEK4321 Hard Plastic Carrying Case for instrument (requires AC2100) RM2000B Rackmount Kit 071-1075-xx Programmer s Manual English Only 071-1828-xx Service Manual English Only 174-4401-xx USB Host-to-Device Cable, 3 ft. long Recommended Probes Probe P2220 10X to 1X Switchable Passive probe (200 MHz when 10X is selected) P6101B 1X Passive probe (15 MHz, 300 V RMS CAT II rating) P6015A 1000X High-voltage Passive probe (75 MHz) P5100 100X High-voltage Passive probe (75 MHz) P5200 High-voltage Active Differential probe (25 MHz) P6021 15 A, 60 MHz AC Current probe P6022 6 A, 120 MHz AC Current probe A621 2000 A, 5 to 50 khz AC Current probe A622 100 A, 100 khz AC/DC Current probe/bnc TCP303/TCPA300 15 A, 15 MHz AC/DC Current probe/ampli er TCP305/TCPA300 50 A, 50 MHz AC/DC Current probe/ampli er TCP312/TCPA300 30 A, 100 MHz AC/DC Current probe/ampli er TCP404XL/TCPA400 500 A, 2 MHz AC/DC Current probe/ampli er www.tektronix.com 5

Data Sheet Service s* 5 C3 Calibration Service 3 Years C5 Calibration Service 5 Years D1 Calibration Data Report D3 Calibration Data Report 3 Years (with C3) D5 Calibration Data Report 5 Years (with C5) CA1 Provides a single calibration event or coverage for the designated calibration interval, whichever comes rst * 5 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms. Service Offerings (Available after purchase) TDSxxxxB-CA1 Provides a single calibration event or coverage for the designated calibration interval, whichever comes rst The Complete Measurement Solution The AFG3000 Series arbitrary function generator pairs with the TDS1000B Series digital storage oscilloscopes to deliver the two elements of a complete measurement solution stimulus and acquisition. This instrument combines the capabilities of a function generator with the power of an arbitrary waveform generator, offering the performance needed to accurately verify, validate, and characterize designs with ease and con dence at a price you can afford. The Tektronix Customer Service Advantage You can trust Tektronix to offer unequalled engineering expertise and a customer-centric approach to ensure the optimal performance of your Tektronix products and maximize the lifetime value of your Tektronix investment. With service from Tektronix you get: Access to the source of product knowledge; unsurpassed technical expertise Your challenges solved by front-line technical experts, design engineering reinforcement, and online support tools Comprehensive and thorough support provided worldwide, including software and rmware updates, data reports, and adjustments Ef ciency and convenience; no-hassle service from initial service call to turnaround and delivery Flexible repair and calibration service with access to the best on-call technical troubleshooting staff in the industry, with over 20 years of training per support engineer Customer-centric approach dedicated to serving your needs everyday with services designed to optimize your product performance, increase productivity and ROI by delivering a xed cost of ownership, and ef cient management of service Get checked by Tektronix. Visit www.tektronix.com/serviceandsupport. Product(s) are manufactured in ISO registered facilities. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. 6 www.tektronix.com