Geneva. Sinfonia. Geneva. English Français Español /ÄM /07.08

Documentos relacionados
GROHE Ondus. English...1 Français...2 Español /ÄM /04.08

Talia. Talia. English...1 Français...2 Español /ÄM212225/04.08

NL...6 PL...11 P...16 BG...21 CN...26 GB...2 S...7 UAE...12 TR...17 EST...22 UA

Allure. Allure. English...1 Français...2 Español /ÄM /12.06

Linie Europlus Sink Mixer

Eurodisc. Eurodisc. English...1 Français...2 Español...3. Design & Quality Engineering GROHE Germany /ÄM /08.11

Ladylux Café. Ladylux Café. English Français Español /ÄM /07.08

English...1 Français...2 Español /ÄM /03.07

NL...6 PL...11 P...16 BG...21 CN...26 GB...2 S...7 UAE...12 TR...17 EST...22 UA

T87 Range Stops INSTALLATION APPLICATION INSTALLATION INSTRUCTIONS EFS

Kensington. Kensington. English...1 Français...2 Español...3. Design & Quality Engineering GROHE Germany /ÄM /11.

With Flange: 1/2" Copper pipe stub-out length from finished wall surface

/ÄM219525/ Design & Quality Engineering GROHE Germany

π H-4039 SPILL CONTAINMENT WORKSTATION CONNECTORS ASSEMBLY uline.com TOOL NEEDED

E-915. Monomando Alto con Desagüe Automático con Rebosadero Magna DX Tall Single Control Lavatory Faucet with Pop - Up Drain ,9" 68 2,7"

ASSEMBLY DRAWING / SPARE PARTS

Allura. Installation and Service Instructions. Widespread Lavatory Faucet SLW-7612-RP. Quick Install Guide Widespread Lavatory Faucet, SLW-7612-RP

Installation Guide C. Under-Mount Bathroom Sink

Installation Guide C. Pop-Up Drain

Installation Guide C. Lavatory Drains

Grohtherm 3000 Cosmopolitan

English...1 Français...2 Español...3. Design + Engineering GROHE Germany /ÄM /04.13

INSTALLATION / INSTALACIÓN / INSTALLATION

Installation Guide C. Vessels Lavatory

Faucet Repair. Lav/Kitchen. Faucet Repair Made Easy!

Europlus. Europlus. English...4 Français...6 Español...8. Design + Engineering GROHE Germany /ÄM /03.13

Antes Antes de de conectar la la grifería a la la distribución de de agua, purgar purgar muy muy bien bien. G ½ x 14 64

Sheridan Kitchen Cart / Cuisine Panier / Cocina Cesta

Page English 2 Español 8 Stands

Antigona. Antigona. Tecnología. Belleza vintage. Technology Technologie

Installation Guide B. Exposed Electronic Valve

Faucet Repair. Tub/Shower. Faucet Repair Made Easy! Committed to Quality, Driven by Innovation.

INSTALLATION INSTRUCTIONS ECLIPSE FUEL DOOR PART # MZ313512

Flashcards Series 5 El Agua

SYSTEM INSTALLATION MANUAL MANUAL DE INSTALACIÓN

Installation Guide. L31227 ( ) Rev 6/10. Installation Instructions for the ILAS III Valve

OPERACIÓN DE MANERALES DIMENSIONES DE DISTANCIA A CENTRO DE DESCARGA

Installation Guide G. Kitchen Sink Faucet

(Stainless-Steel) (Brass)

Installation Guide. Entertainment Sink Faucet

*P * L/LV9000-Series. 2 All functions Todas las funciones Toutes fonctions. 1 All functions Todas las funciones Toutes fonctions

Installation Instructions Instrucciones para la instalación Instructions d installation

2.4L ENGINE BLOCK HEATER CHRYSLER 200 / DODGE AVENGER CALL OUT DESCRIPTION QUANTITY 1 Engine Block Heater 1 2 Cord 1 3 Tie Straps 2

Installation Guide C. Ceramic Lavatory Faucet

DESCRIPCIÓN DESCRIPTION FIGURA FIGURE

π H-2888 RECYCLED PLASTIC BENCH WITH BACK parts uline.com TOols NEEDED

Auto Rain Lawn Gear LA

Bronze Valves válvulas de bronce

Parts/Pièces/Herrajes

4 SCREWPLUG SUP279 1/6 K CONTENTS Hood Protector Instructions Sheet Alcohol Wipe Screwplugs Large Screws Large Washers Rust Inhibitor

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual DECLUTCHABLE WORM GEAR

Campbell Hausfeld Electric Powered Pressure Washers

2008 Series Hemodialysis Machine Operator s Manuals Addendum for Concentrate Connection

Datos Principales Main Data. Capacidad Capacity (L) 25 L 35 L. Código Code Peso Weight (Kg) Notas Notes

#10 x 3-in Washer Head Screw #8 x 3/4-in Truss Head Screw

Last As Long As the Building. ADA Compliant

Guía de instalación. Grifería empotrada de bañera y ducha M2-A K-675M, K-676M K-675K, K-676K

Electroválvula 3/2 24V 3/2 24V Electrovalve



SP-U. Soporte colgado universal para JK26 / JK10 / JK10MA / JK12 / JK12MA / JK15 / KEY10 / KEY12 / KEY15

Válvulas (blanco / pulgadas) Valves (white / inch) Reguladores de caudal Control valves. Características. Features

INSTRUCCIONES DE INSTALACIÓN Panel de ducha

THERMAL SWITCH AND SOLENOID VALVE INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA LA INSTALACIÓN DE LA VÁLVULA SOLENOIDE Y DEL INTERRUPTOR TÉRMICO

Vidrio Industrial POBEL, S.A.

Installation Guide. Kitchen Sink Faucet. Français, Page 6 Español, Página 10 K-16109, K A

Sistema de retención para mangueras de presión

Kensington VP0. Kensington. English...1 Français...2 Español /ÄM /09.07

Installation Guide. Kitchen Sink Faucet

Grifería Industrial. Características Constructivas

π H-3905 PUSH FOAMING SOAP DISPENSER INSTALLATION uline.com MOUNTING INSTRUCTIONS APPLYING DISPENSER LABEL TOOLS NEEDED TAPE MOUNTING

Model/Modelo: SR42UBEVS

TECHNICAL SERVICE POINTER

π H-2561 Parts Assembly uline.com Tools needed H-2562 rectangular picnic table

MULTI-FUNCTIONAL COMPUTER TABLE

INSTALLATION / INSTALACIÓN / INSTALLATION

Mobile Floor Crane. Form No Parts List for: B D-01001AA. Sheet No. 1 of 1

Plastic restrain Plastic wall bra

Video Server. Quick Installation Guide. English, Español

Configure el cable de interconexión de acuerdo con la Fig. 1. para un funcionamiento adecuado. Figura 1 Diagrama de ensamblaje del cable

INSTALLATION INSTRUCTION Vogue WS-3120

Installation Guide. Sink Strainer K-8816 K-8817

Actuadores Neumáticos Tipos - PN 5700 y PN 6700 Instrucciones de Instalación y Mantenimiento

AENOR AUTORIZA EL USO DE ESTE DOCUMENTO A GAS NATURAL SDG, S.A.

INSTRUCCIONES DE USO. ASPERSOR POP UP Modelo VYR-650

H TIER DISPLAY TABLE

MANUAL DE INSTRUCCIONES PARRILLA BARBACOA (18 ) ED-4047BQ

GARMENT STORAGE CENTER WITH SHELVES PARTS ASSEMBLY. uline.com POST ASSEMBLY TO INSTALL OPTIONAL CASTERS TO INSTALL SELF-LEVELERS

Essence. Essence. English...1 Français...2 Español...3. Design & Quality Engineering GROHE Germany /ÄM /07.08

Descripción Description

Push Pull Installation Procedure

Instrucciones de instalación

Conjuntos anclaje para cables de fibra óptica. Dead end set for fibre optic cables.

Antes Antes de de conectar la la grifería a la la distribución de de agua, purgar purgar muy muy bien bien. G ½ x 14 64


The Bonded Flange Center Drain Series are intended for use with the following waterproofing methods:

USE AND CARE GUIDE SINGLE HANDLE TUB AND SHOWER FAUCET

Installation Guide. Diverter Valve Kit

BATHROOM FAUCET ROBINET DE SALLE DE BAINS GRIFO PARA BAÑO

Transcripción:

20 801 Geneva Sinfonia Geneva English...1...4 Français...2...6 Español...3...8 95.912.231/ÄM 211510/07.08

1 Please pass these instructions on to the end user of the fitting! S.v.p remettre cette instruction à l'utilisateur de la robinetterie! Entregue estas instrucciones al usario final de la grifería!

2

1 2 F G H E D D1 A 32mm 17mm C B H1 I J K K1 B1 B2 B 13mm 3 4 M M1 19mm N L 3

Application Operation is possible in conjunction with: Pressurized storage heaters Operation is not possible with: Low-pressure storage heaters (displacement water heaters) Technical data Note Major pressure differences between cold and hot water supply should be avoided. Installation See dimensional drawing on page 1. English Spout 1. Place the O-ring (I) and the escutcheon (H1) on the basin, see fig. [2]. 2. Insert the spout (H) through the escutcheon (H1) and basin. 3. Place the gasket (J) against the bottom of the basin and fasten with the flange (K) and nut (K1). Tighten hexagon nut with a 13mm socket wrench. 4. Connect flexible hoses (L) to the side valves, see figs. [3] and [4]. Max. flow 8.3 L/min or 2.2 gpm/60 psi Mount lift rod and pop-up drain GROHE WaterCare 5.7 L/min or 1.5 gpm/60 psi Flow pressure - min. 7.25 psi - recommended 14.5-72.5 psi - greater than 72.5 psi, fit with pressure reducing valves Max. operating pressure 145 psi Test pressure 232 psi Temperature Connect wideset - max. (hot water inlet) 176 F Water connection cold - Right hand hot - Left hand 1. Screw the knob (M1) to the upper lift rod, see fig. [3]. 2. Insert the lift rod (M) through the spout and screw on the lower lift rod (N). The connector is at the lower lift rod (N). 3. Fit pop-up drain (28 957), see page 2. Ensure that flange of pop-up drain is sealed. Connect the side valves to the water supply. Insure the supplied washers are used for all connections. The cold water supply should be connected on the right side valve (marked blue) and the hot water supply to the left valve (marked red). Open cold and hot water supply and check connections for leakage. Flush pipes thoroughly! Side valves Valve with a groove on the top edge of the cartridge (A) and in addition marked with blue tape should be mounted on the right (cold water) side, see fig. [1]. Valve without a groove on the top edge of the cartridge (A) and in addition marked with red tape should be mounted on the left (hot water) side. 1. Screw the mounting set (B) to the bottom of the thread of the side valve (C), see fig. [1]. Make sure that the rubber washer (B1) is on the top of the fiber washer (B2). 2. Insert the side valve (C) through the basin hole from below. 3. Place the escutcheon O-ring (D1) on the basin and screw down the escutcheon (D) until it stops. 4. Screw the cap (E) down to the escutcheon (D). 5. Secure the handle (F) or lever (G) to the stem of the ceramic headpart (A). It is recommended that the lever handle (G) be installed so they point away from the spout when in the off position. If the gap between the handle and the cap is excessive, back off the cap (E) and the escutcheon (D) to minimize the gap. 6. Tighten the mounting set (B) from below to secure the valve. Maintenance Inspect and clean all parts, replace as necessary and grease with special grease. Shut off cold and hot water supply. I. Ceramic cartridge, see page 2. 1. Remove handle (18 731) or lever 18 732) and cap. 2. Unscrew the ceramic cartridge (45 882, 45 883) using a 17mm wrench. 3. Change complete ceramic cartridge or O-ring. Observe the different replacement part numbers of the cartridges. II. Flow control, see page 2. Unscrew and clean flow control (13 931). Assemble in reverse order. Replacement parts, see page 2 ( * = special accessories). Care Instructions for care of this faucet will be found in the Limited Warranty supplement. 4

1 2 F G H E D D1 A 32mm 17mm C B H1 I J K K1 B1 B2 B 13mm 3 4 M M1 19mm N L 5

Domaine d'application Le service est possible en combinasion avec: Des chauffe-eau à accumulateurs sous pression Le service n'est pas possible en combinasion avec: Des systèmes d eau chaude à écoulement libre Français Caractéristiques techniques Débit maxi. 8,3 l/min ou 2,2 g/min/4,1 bar GROHE WaterCare 5,7 l/min ou 1,5 g/min/4,1 bar Pression dynamique - mini. 0,5 bar - recommandée 1-5 bar - supérieure à 5 bar, mise en place d'un réducteur de pression Pression de service maxi. 10 bar Pression d'épreuve 16 bar Température - maxi. (admission d'eau chaude) 80 C Raccord d'eau froide - à droite chaude - à gauche Remarque Il convient d'éviter toute différence de pression importante entre l'arrivée d'eau froide et chaude. Bec 1. Poser le joint torique (I) et la rosace (H1) sur le lavabo, voir fig. [2]. 2. Insérer le bec (H) dans la rosace (H1) et le lavabo. 3. Poser le joint (J) sur le fond du lavabo et le fixer avec la bonde (K) et l'écrou (K1). Visser la vis six pans avec une clé Allen de 13mm. 4 Brancher les flexibles (L) sur les robinets d'arrêt, voir fig. [3] et [4]. Montage de la tirette et de la garniture de vidage 1. Visser le bouton (M1) à la tirette supérieure, voir fig. [3]. 2. Insérer la tirette (M) dans le bec et la visser sur la tirette inférieure (N). La tirette de vidage inférieure (N) comporte le raccord. 3. Monter la garniture de vidage (réf. 28 957), voir le page 2. Vérifier l'étanchéité de la bonde de vidage. Brancher la robinetterie Raccorder les robinets d'arrêt à l'alimentation en eau. S'assurer que toutes les rondelles fournies sont utilisées pour les raccords. L'arrivée d'eau froide doit être raccordée au robinet droit (repéré en bleu) et l'arrivée d'eau chaude au robinet gauche (repéré en rouge). Montage Tenir compte de la cote du schéma sur le page 1. Purger les tuyauteries! Robinets d'arrêt Le robinet avec une rainure sur le capot (A) et repéré par du ruban bleu doit être posé sur le côté droit (eau froide), voir fig. [1]. Le robinet sans rainure sur le capot (A) et repéré par du ruban rouge doit être posé sur le côté gauche (eau chaude). 1. Visser au préalable la fixation (B) sur le robinet d'arrêt (C) de la d'au d'assembleur, voir fig. [1]. Assurez-vous que la rondelle en caoutchouc (B1) est sur le dessus de la rondelle de fibre (B2). 2. Introduire le robinet d'arrêt (C) dans le trou du lavabo, par le bas. 3. Placer le joint torique de la rosace (D1) sur le lavabo et visser la rosace (D) jusqu'en butée. 4. Visser le capot (E) vers le bas la rosace (D). 5. Fixer la poignée (F) ou le levier (G) sur l'axe de la tête en céramique (A). On lui recommande que le traitement de levier (G) soit installé ainsi eux se dirigent loin du bec quand dans la position de repos. Si l'intervalle entre le poignée et le chapeau est excessif, dégagez le capot (E) et la rosace (D) pour réduire au minimum l'intervalle. 6. Serrer au préalable la fixation (B) par le dessous pour fixer le robinet. Ouvrir les arrivées d'eau chaude et d'eau froide et vérifier l'étanchéité des raccords. Maintenance Contrôler, nettoyer et, si nécessaire, remplacer les pièces. Les graisser avec une graisse spéciale. Fermer les arrivées d'eau froide et d'eau chaude. I. Tête en céramique, voir le page 2. 1. Enlever et retirer la poignée (18 731) ou le levier (18 732) et le capot. 2. Dévisser la tête en céramique (45 882, 45 883) en utilisant une clé de 17mm. 3. Remplacer la tête complète et le joint torique. Tenir compte des différents numéros de pièce de rechange des têtes. II. Régulateur de jet, voir le page 2. Desserrer et nettoyer le régulateur de jet (réf. 13 931). Montage dans l'ordre inverse. Pièces de rechange, voir page 2 (* = accessoires spéciaux). Entretien Vous trouverez les instructions d'entretien de ce mitigeur dans le supplément Garantie Limitée. 6

1 2 F G H E D D1 A 32mm 17mm C B H1 I J K K1 B1 B2 B 13mm 3 4 M M1 19mm N L 7

Campo de aplicación Es posible el funcionamiento en conjunción con: Acumuladores de presión No instalar con: Acumuladores de baja presión (calentadores de agua sin presión) Instalación Respetar el croquis de la página 1. Purgar las tuberías! Válvulas laterales La válvula con una ranura en la parte superior del cabezal (A) que además está marcada con cinta azul debe montarse a la derecha (agua fría), ver la fig. [1]. La válvula sin una ranura en la parte superior del cabezal (A) que además está marcada con cinta roja debe montarse a la izquierda (agua caliente). 1. Atornille el grupo de montaje (B) determinado al fondo de la cuerda de rosca de la válvula lateral (C), ver la fig. [1]. Cerciórese de que la arandela de goma (B1) esté en la tapa de la arandela de la fibra (B2). 2. Inserte la válvula lateral (C) desde abajo a través del agujero de la pila. 3. Coloque la junta toroidal del embellecedor (D1) sobre la pila y atornille el embellecedor (D) hasta que haga tope. 4. Atornille la tapa (E) abajo al embellecedor (D). 5. Fije el pomo (F) o la palanca (G) al vástago de la montura cerámica (A). Se recomienda que la palanca (G) sea instalado tan ellos señala lejos del caño cuando en la posición de reposo. Si el boquete entre la manija y el casquillo es excesivo, retroceda la tapa (E) y al embellecedor (D) para reducir al mínimo el boquete. 6. Apriete el grupo de fijación (B) desde abajo para asegurar la válvula. Español Caño 1. Coloque la junta toroidal (I) y el embellecedor (H1) en la pila, ver fig. [2]. 2. Inserte el caño (H) a través del embellecedor (H1) y la pila. 3. Coloque la junta (J) contra el fondo de la pila y fíjela con la brida (K) y la tuerca (K1). Apriete la tuerca hexagonal con una llave de cubo de 13mm. 4. Empalme los flexos (L) hasta las válvulas laterales, ver fig. [3] y [4]. Datos técnicos Caudal máx. 8.3 L/min o 2.2 gpm/60 psi GROHE WaterCare 5.7 L/min o 1.5 gpm/60 psi Montar el tirador y el desagüe Presión - mín. 7.25 psi - recomendada 14.5-72.5 psi - si la presión es superior a 72.5 psi, se deberá instalar una válvula reductora de presión Presión de utilización máx. 145 psi Presión de verificación 232 psi Temperatura - máx. (entrada del agua caliente) 176 F Acometida del agua fría - a la derecha caliente - a la izquierda Acople el conjunto Nota Deberán evitarse las diferencias de presión entre las acometidas del agua fría y del agua caliente. 1. Atornille el volante (M1) a la varilla de elevación superior, ver fig. [3]. 2. Inserte la varilla de elevación (M) a través del caño y atorníllelo a la varilla de elevación inferior (N). El conector está en la varilla de elevación inferior (N). 3. Montar el desagüe automático (28 957), ver la página 2. Asegúrese de que esté sellado el cuerpo de la válvula del desagüe. Conecte las válvulas laterales a la toma de agua. Asegúrese de que en todas las conexiones se emplean las arandelas suministradas. La toma de agua fría debe conectarse a la válvula lateral derecha (marcada en azul) y la toma de agua caliente a la válvula izquierda (marcada en rojo). Abra las tomas de agua fría y caliente y compruebe que no existen fugas en los empalmes. Mantenimiento Revisar, limpiar y cambiar eventualmente todas las piezas, y engrasarlas con grasa especial para grifería. Cierre el suministro de agua caliente y fría. I. Montura cerámica, ver la página 2. 1. Quitar la empuñadura (18 731) o la palanca (18 732) y la tapa. 2. Desatornille la montura cerámica (45 882, 45 883) empleando una llave de 17mm. 3. Cambiar la montura cerámica completa o la junta toroidal. Prestar atención a los diferentes números de piezas de repuesto de las monturas. II. Regulador de caudal, ver la página 2. Desatornille y limpie el regulador de caudal (13 931). El montaje se efectúa procediendo en orden inverso. Componentes de sustitución, ver la página 2 (* = accesorios especiales). Cuidados periódicos En el suplemento Garantía a Limitada encontrará las instrucciones relativas al cuidado de esta batería. 8

Grohe America Inc. 241 Covington Drive Bloomingdale, IL 60108 U.S.A. Technical Services Phone: 630/582-7711 Fax: 630/582-7722 Grohe Canada Inc. 1226 Lakeshore Road East Mississauga, Ontario Canada, L5E 1E9 Technical Services Services Techniques Phone/Tél: 905/271-2929 Fax/Télécopieur: 905/271-9494