INDICE DE CILINDROS DE GAS CM CM GAS SPRING INDEX

Documentos relacionados
SERIE AG FD: DIMENSIONES INTERMEDIAS AG FD SERIES: COMPACT HEIGHT GAS SPRINGS

INDICE DE CILINDROS DE GAS TB TB GAS SPRING INDEX

INDICE DE CILINDROS DE GAS LC LC GAS SPRING INDEX. SERIE LC: La misma fuerza al menor coste SERIE LC: Same force at lowest cost

SERVICIO PERSONALIZADO PARA SU MERCADO GLOBAL

INDICE DE CILINDROS DE GAS CS CS GAS SPRINGS INDEX SERIE CS: CILINDROS COMPACTOS CS SERIES: COMPACT GAS SPRINGS. CS dan 6-50 mm Ø32

INDICE DE CILINDROS DE GAS CW CW GAS SPRING INDEX

INDICE DE LAS SERIES MICRO MICRO GAS SPRING INDEX

INDICE DE CILINDROS DE GAS VAM VAM GAS SPRING INDEX SERIE VAM: CILINDROS RETARDADOS SERIE VAM: SPEED CONTROLLED GAS SPRINGS

INDICE DE CILINDROS DE GAS DGS DGS GAS SPRING INDEX

INDICE DE CILINDROS DE GAS ESTANDAR STANDARD GAS SPRING INDEX. APF dan mm Ø45. AG dan mm Ø120

BA - IP dan mm in Ø

INDICE DE EXPULSORES PLUNGER INDEX MB-XXL MB-XX-XXL MBS MBP MBT Z-M MBHR EXU EXY EXT PME PGE PGN

Subfamilia109.2 CILINDROS ISO VDMA Serie MCQI2 (ø32-ø100)

With temperature switch Cover for protection against high surface temperatures

Extend your ideas. Controla el movimiento. Acero Inoxidable

ARTICULO: 2528A Válvula de esfera paso total Bridada, ANSI Clase 150, Acero Inox Stainless Steel full port ball valve, ANSI Class 150, Flanged ends

ARTICULO: 2528A Válvula de esfera paso total Bridada, ANSI Clase 150, Acero Inox Stainless Steel full port ball valve, ANSI Class 150, Flanged ends

Series 5.7. Series 5.7. Sizes Tamaños: 05 / 11 / 16 / 23 / 50 / 10 / 13 / 18 / 36

Regulador de presión

PISTOL NEEDLE SCALER KIT

Type WGK WITH SMALL BLADE PITCH

Type KUL. Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation

T R A N S TECHNICAL SPECIFICATIONS:

Inversores de giro Rotation reverse

BAT/ Regenera los vapores en líquido - Altura adaptable - Conexión Push-in. BAT/ Kit 24V. BAT/ Kit 36 V. BAT/ Kit 48 V

Instrucciones de Uso y Seguridad / Use and Security Instructions:

EBRO EBRO CONTADORES DE AGUA / WATER METERS. FLUIDAL, S.L Fax

MQS-A ISO A POPPET VALVES KEY FEATURES CARACTERÍSTICAS PRINCIPALES PLUS PERFORMANCES CARACTERÍSTICAS ADICIONALES

Datos Principales Main Data. Codigo Derechas CW Part Number Izquierdas CCW

Pneumatic Desoldering Module

PVC-U SWING CHECK VALVES

LOW SPEED RIGHT ANGLE CUT-OFF TOOL

Art Válvula de Seguridad a Escuadra Art Safety Angle Valve

ARTICULO: 2103 Válvula de mariposa tipo wafer Butterfly valve wafer type

MINI INDUSTRIAL DUTY DIE GRINDER

Datos Principales Main Data. Izquierdas CCW Desplazamiento Displacement (cm 3 /rev)

Type WG FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Tirador 3 vías, 5 vías y Palanca 2 vías 3 ways puller, 5 ways and 2 ways lever

PVC-U BUTTERFLY VALVES INDUSTRIAL SERIES

ELEMENTOS DE FIJACIÓN

Universal aftermarket speaker installation kit

ARTICULO: 2109B Válvula de mariposa tipo wafer Butterfly valve wafer type

INDICE DE SPRINTERS SPRINTER INDEX

Índice Index Introdución a la empresa Introduction to the company Motores hidráulicos Hydraulic motors Nomenclatura de referencia Coding system Datos

MANGUERAS FLEXIBLES METÁLICAS ASISTENCIA TECNICA

UNIVERSAL COUPLINGS AND FLANGE ADAPTORS FOR RIGID PIPELINES / MANGUITOS Y BRIDAS UNIVERSALES PARA LA UNIÓN DE TUBERÍAS RÍGIDAS

Process Control Supply, C.A.

Productinformatie J+J AUTOMATION.

ELEMENTOS DE FIJACIÓN

GEARBOX TECHNICAL CHARACTERISTICS

RECOMENDACIONES DE UTILIZACION DE LAS UNIDADES DE PUNZONADO RECOMMENDATION OF USE OF THE PUNCHING UNITS 7F - A

RECOMENDACIONES DE UTILIZACION DE LAS UNIDADES DE PUNZONADO RECOMMENDATION OF USE OF THE PUNCHING UNITS 7H - A

ACONDICIONADORES AUTONOMOS VERTICALES AGUA-AIRE CONDENSADOR DE PLACAS PACKAGED VERTICAL AIRCONDITIONER WATER COOLED CONDENSER

QUICK CHANGE REVERSIBLE AIR DRILL KIT

RIGHT ANGLE DIE GRINDER

COMPANY STANDARD SPECIAL POWER UNIT APPLICATIONS

RECOMENDACIONES DE UTILIZACION DE LAS UNIDADES DE PUNZONADO RECOMMENDATION OF USE OF THE PUNCHING UNITS 7D - A

INDICE. INDEX Página / Page. - Datos Técnicos / Techical Specifications Serie IEP 0200 / IEP 0200 Series. 06

Art.: Válvula Reductora de Presión a Pistón con Filtro Piston Pressure Reducer Valve with Filter

Válvula de esfera paso total Bridada, Acero Inoxidable Stainless Steel full port ball valve, Flanged ends

CILINDROS HIDRÁULICOS HYDRAULIC CYLINDERS

RECOMENDACIONES DE UTILIZACION DE LAS UNIDADES DE PUNZONADO RECOMMENDATION OF USE OF THE PUNCHING UNITS 7F - A

ANTIVIBRATORS ANTIVIBRADORES

DISTRIBUIDOR MANUAL 202 HAND OPERATED CONTROL VALVE 202

VÁLVULA EN ACERO INOXIDABLE STAINLESS STEEL VALVES

CILINDROS HIDRÁULICOS HYDRAULIC CYLINDERS

RECOMENDACIONES DE UTILIZACION DE LAS UNIDADES DE PUNZONADO RECOMMENDATION OF USE OF THE PUNCHING UNITS 7D - A

Gama de accesorios y válvulas de bola de PVC Máxima garantía en la circulación del agua de la piscina

VALVULAS DE GUILLOTINA SERIE UB PROGRAMA DE FABRICACION

Art Actuadores Eléctricos Fracción de vuelta

Installation Guide. Green momit

Accesorios para ventosas Vacuum cups accessories

MT442 MT642 U S E R S M A N U A L

(Inoxidable - Cobre - Plástico)

FICHA TÉCNICA / DATA SHEET DOWNLIGHT LED LEDION MINI 25W. Ref.: 3001 DESCRIPCIÓN / DESCRIPTION INSTALACIÓN / INSTALLATION INCLUYE / INCLUDES

Low Ambient Conversion For LG Single and Flex Multi Inverters

Important Topics Instructors Guide

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

ADHESIVE INSTALLATION GUIDE ENGLISH ESPAÑOL PAGE 2 PÁGINA 4

MF222 U S E R M A N U A L

Difference of Hydraulic UTM. Load Frame type different: (Page 1-9) Cualquier duda o aclaración favor de llamarnos, estamos para SERVIRLE

Sistema de retención para mangueras de presión

BEM 23/30/40/45 BE L 50/60/80/100/120

L M Lomisa Distribuciones y Proyectos S.L

RTA-B002 DIMENSIONS MAXIMUM WEIGHT CAPACITIES. Highest position. Lowest position. Product Size: 22"W x 16"D x 30.5~46.5"H

FLEJADORAS FLEJADORAS STRAPPING - MACHINES

VECTORES. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Incremental Rotary Encoders

CMM REDUCTORES SINFÍN Y CORONA DOBLE REDUCCIÓN DOUBLE REDUCTION WORM-WORM GEARBOXES CMM CMM NEMA DIMENSIONS

MÓDULOS L-VAC L-VAC MODULES

Transcripción:

www.azolgas.es INDICE DE CILINDROS DE GAS CM CM GAS SPRING INDEX CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET SERIE CM: DIMENSIONES INTERMEDIAS CM SERIES: COMPACT HEIGHT GAS SPRINGS 365 CM 200 200 dan 10-80 mm Ø25 CM 350 350 dan 10-80 mm Ø32 CM 500 500 dan 10-100 mm Ø38 CMR 500 500 dan 15-100 mm M38 x 1.5 CM 1000 1000 dan 10-200 mm Ø50 CM 1500 1500 dan 10-200 mm Ø63 CM 2500 2500 dan 10-200 mm Ø75 CM 4000 4000 dan 25-200 mm Ø95 CM 6500 6500 dan 25-200 mm Ø120 CM 10000 10000 dan 25-200 mm Ø150 SERIE CM: CM SERIES: - Rango de fuerzas / Forces range: ------------------------------------------------------------------- 200-10000 dan - Carreras disponibles / Available strokes: -------------------------------------------------------------- 10-200 mm - Diámetros / Diameters: --------------------------------------------------------------------------------------- 25-150 mm CM-200 ------------------------------------------------- CM-350 ------------------------------------------------- CM-500 ------------------------------------------------- CMR-500------------------------------------------------- CM-1000 ------------------------------------------------- Pag. 370 Pag. 372 Pag. 374 Pag. 376 Pag. 378 CM-1500 --------------------------------------------------- Pag. 382 CM-2500 --------------------------------------------------- Pag. 386 CM-4000 --------------------------------------------------- Pag. 390 CM-6500 --------------------------------------------------- Pag. 394 CM-10000 --------------------------------------------------- Pag. 398

366 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CARACTERISTICAS DE LA SERIE CM ABOUT CM SERIES MODELO MODEL FUERZA FORCE ( dan ) Ø CUERPO Ø BODY REPARABLE REPAIR CONEXION CONNECTION PUERTO DE CARGA FILLING PORT CM 200 200 25 SI / YES NO M6 CM 350 350 32 SI / YES NO M6 CM 500 500 38 SI / YES NO M6 CMR 500 500 M38 x 1.5 SI / YES NO M6 CM 1000 1000 50 SI / YES SI / YES 1/8 Gas CM 1500 1500 63 SI / YES SI / YES 1/8 Gas CM 2500 2500 75 SI / YES SI / YES 1/8 Gas CM 4000 4000 95 SI / YES SI / YES 1/8 Gas CM 6500 6500 120 SI / YES SI / YES 1/8 Gas CM 10000 10000 150 SI / YES SI / YES 1/8 Gas CARRERA STROKE 25 mm DIAMETRO DIAMETER 50 mm 145 mm 135 mm 120 mm 100 mm 88 mm Coeficiente multiplicador Multiplier coefficient 1.8 ( dan ) 1.7 CM 10000 10000 1.6 9000 CM 6500 1.5 8000 CM 4000 7000 CM 2500 6000 CM 1500 5000 CM 1000 4000 CM 500 3000 CMR 500 2000 1000 CM 350 1.4 1.3 1.2 1.1 1.0 0 12 25 38 Carrera en mm Stroke in mm AG 750 XCF DIAGRAMA DE AUMENTO DE PRESION EN FUNCION DE LA CARRERA RECORRIDA 50 CD 1000 CM 1000 AG 750 GN AG 750 FD CW 1000 63 80 100 125 PRESSURE INCREASE DIAGRAM ACCORDING TO STROKE USED 0 10 30 50 70 DIAGRAMA DE FUERZAS EN FUNCION DE LA PRESION DE CARGA 90 110 130 150 ( bar ) CM 200 FORCE DIAGRAM ACCORDING TO LOADING PRESSURE Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... --- Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CARACTERISTICAS TECNICAS TECHNICAL FEATURES 367 REQUISITOS DE SEGURIDAD / SAFETY REQUIREMENTS Los resortes de gas son recipientes con gas nitrógeno a una presión máxima de 150 bar. s are containers charged with nitrogen gas at maximum pressure of 150 bar. No manipule ningún elemento del mismo sin estar seguro de que el resorte de gas está descargado o que sabe cómo proceder para descargarlo. Los resortes de gas cumplen con la Directiva 97/23/CE de equipos a presión ( PED ), y llevan el marcaje CE sólo aquellos que así vienen determinados por la misma. No se deben manipular los resortes de gas por personal sin la preparación adecuada y sin las instrucciones de mantenimiento de resortes de gas de Azolgas. Do not manipulate any part of gas spring without being sure that it is completely discharged, or you are trained in handling the process of unload. Azolgas gas springs meet European Community Directive 97/23/CE related to Pressure Equipment Devices ( PED ), and only the CE Mark identification will be laser etched according to the mentioned Directive. Never handle gas springs by personnel without the appropriate training, and always following the outlined operating instructions from Azolgas. MOD. STANDARD CM VASTAGO PISTON ROD RASCADOR SCRAPER ARO LOCKING RING CASQUILLO SELF- LUBRICATED SLEEVE JUNTA TORICA O-RING EMPAQUETADURA GASKET TAPA SUPERIOR UPPER PLUG GUIA GUIDE RING EMBOLO PLUNGER CUERPO BODY TAPON SEALING PLUG VALVULA LOADING VALVE SERIE CM: DIMENSIONES INTERMEDIAS CM SERIES: COMPACT HEIGHT GAS SPRINGS - Mayor fuerza. - Menores dimensiones. - Igual diámetro que los cilindros ISO estándar. - Higher force. - Smaller dimensions. - Same diameter than ISO Standard gas springs.

368 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET RECOMENDACIONES DE UTILIZACION OPERATING INSTRUCTIONS APLICACION DE UN RESORTE DE GAS / GAS SPRINGS APPLICATION La correcta aplicación de un resorte de gas va a evitarle problemas de fugas o sobrepresión, y va a proporcionarle la vida de uso para la que se diseñó. The correct gas spring application is going to avoid problems related to leaks or overpressure, and it will provide the life guarantee as it was designed. INSTRUCCIONES DE INSTALACION: - El resorte de gas debe ir firmemente sujeto al troquel, bien por la rosca de la parte inferior del cuerpo o bien mediante las bridas que AzolGas ofrece en cada modelo. - En caso de introducir el resorte de gas en una cajera taladrada en el troquel, el cuerpo debe ajustarse al agujero de forma que se impida su cabeceo ( se recomienda que la cajera tenga la profundidad del cuerpo ). Si el agujero fuese mayor, este ajuste puede realizarse mediante un casquillo plástico calado en el cuerpo. En caso de dejar al resorte de gas alojado libre en la cajera, el agujero debe tener como máximo 1mm más en diámetro que el diámetro del cuerpo. - La rosca de la parte superior del vástago no debe usarse para sujetar el cilindro mediante un tornillo. Los errores de guiado y alineación pueden implicar un deterioro de los elementos de estanqueidad y reducir la vida del resorte. Esta rosca en el extremo superior del vástago debe usarse únicamente en tareas de mantenimiento. - La colocación del resorte de gas debe hacerse lo más paralelamente posible a la fuerza aplicada, con la superficie del vástago perpendicular a dicha fuerza. Las superficies de apoyo de la base del cuerpo o de la brida y el vástago también deben ser perpendiculares a la fuerza aplicada, y deben tener una dureza suficiente. - No se deben aplicar sobre el resorte de gas esfuerzos laterales. Prestar especial atención sobre vibraciones y movimientos laterales mientras el troquel está bajando, comprimiendo los cilindros. PRESION MAX: - La presión máxima de carga del gas nitrógeno es de 150 bar a 20 C en estos modelos. FLUIDOS: - Es importante evitar la presencia de fluidos o partículas sobre el resorte de gas. La mayoría de resortes de gas llevan un rascador que evita que partículas o fluidos puedan introducirse a su interior; no obstante la mejor protección viene de la ausencia de fluidos sobre su superficie. Si el resorte de gas va alojado en una cajera que se puede inundar, cubriendo la parte superior del cuerpo, se pueden hacer unos drenajes en la cajera, de forma que el fluido no la inunde. MOUNTING INSTRUCTIONS: - s have to be firmly fastened to the die tool, either by the thread at the bottom of the body, or by the flange mounts offered by Azolgas for each gas spring model. - Should you install the gas spring in a bored pocket in the die, the gas spring body must be adjusted to the hole in order to avoid undesired lateral movement ( the bored pocket is recommended to have the same length as the gas spring body). If the bored pocket is larger than the cylinder body by more than 1mm, an adjustment can be made by a plastic sleeve on the body of the gas spring. Should the gas spring be placed into a pocket with no fixing sleeve, the bored pocket diameter should not exceed 1mm larger than the gas spring body diameter. - The thread on the top of the rod cannot be used to mount the gas sping. This thread on the top of the rod must only be used in repair and maintenance tasks. Defective guiding in gas springs damages sealing parts and reduces gas spring life expectancy. - Installation of gas springs into the tool must be made in parallel to the force used, with the rod surface perpendicular to the mentioned force. The surface of the gas spring body base, and the rod surface must be placed perpendicular to the force. The surface bearing areas for both body base and rod must have sufficient hardness. - s cannot be exposed to lateral force. Pay special attention to lateral forces and vibrations on the tool when the gas spring is cycled. MAX. CHARGING PRESSURE: Maximum charging pressure for nitrogen gas is 150 bar at 20 C for these gas springs. FLUIDS: It is important to keep gas springs clear of fluids or dirt. Most gas springs have a scraper to assist keeping fluids or dirt from entering the gas spring, nevertheless the best protection is the absence of fluids and dirt. Should the gas spring be installed into a bored pocket, this pocket could be flooded covering the upper part of gas spring body. Holes at the botton of the bored pocket could be made to let fluids go out through these holes and avoid the gas spring being flooded.

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es RECOMENDACIONES DE UTILIZACION OPERATING INSTRUCTIONS 369 APLICACION DE UN RESORTE DE GAS / GAS SPRINGS APPLICATION CADENCIA MAX.: - Según la carrera usada ( mayor carrera, menos ciclos). - Consulten aplicaciones > 100 ciclos por minuto. MAX. STROKES / MINUTE: - Based on stroke used ( the more stroke the less cycles ). - Consult us for applications of more than 100 cycles per minute. TEMPERATURA DE TRABAJO: - Un exceso de temperatura reduce la elasticidad de los elementos de estanqueidad. En general, los resortes de gas no deben superar los 100 C. CARRERA UTIL: - Debe evitarse que la recuperación de la carrera del vástago se haga de forma libre, ya que ello podría dañar a sus componentes. - Es recomendable no usar toda la carrera del resorte de gas y reservar un 10% de la carrera nominal. - Se define como ciclo el recorrido completo de ida y vuelta del vástago dentro del cuerpo del resorte de gas hasta alcanzar la posición inicial. VELOCIDAD: - La velocidad máxima lineal de desplazamiento del vástago a lo largo de las juntas sellantes del gas es de 1.6 m/s. MANTENIMIENTO: - Azolgas recomienda que se sustituyan los cilindros, a partir de 2 millones de ciclos o despues de 10 años. - Invalidación de la durabilidad estimada: Marcas sobre el vástago distintas del desgaste propio por un funcionamiento. (Golpes, proyecciones de soldadura, rayaduras,... ). Instalación inadecuada del resorte de gas ( No fijación del cuerpo o introducción en una cajera demasiado amplia, asiento inclinado o inestable, ubicación del resorte de gas en una cajera inundada por fluídos ) u otra circunstancia que pueda deteriorar totalmente o alguna de las partes del resorte de gas. Utilización a temperaturas distintas de las marcadas ( 0 C - 100 C ). Manipulación del resorte de gas. - Recomendación: Consulte con AzolGas cualquier aplicación que considere especial o en circunstancias distintas de las expuestas en este documento. OPERATING TEMPERATURE: - High temperature can damage seals by reducing their elasticity and finally becoming faulty. In general, gas springs should not work exceeding 100 C. STROKE LENGTH: - When the gas spring is being cycled the rod must avoid returning to it s initial position in an uncontrolled motion, this could damage gas springs parts. - A 10% stroke length allowance is recommended. - The cycle is defined as the complete movement ( up and down ) of the piston rod inside the body of gas spring. MAX. PISTON ROD SPEED: - The maximum piston rod velocity throughout the seals of the gas springs is of 1.6 m/s for this series of Azolgas gas springs. MAINTENANCE: - In any case Azolgas recommends replacing the gas springs after 2 million strokes or after 10 years. - Life expectancy estimation is not valid in the following cases: marks on the rod surface different from normal performance ( rod damaged by being heated, scratches...), installation without being fixed on the gas spring body, gas spring placed into a bored pocket too wide in comparison to the gas spring body diameter, unstable or lateral force / rod surfaces, gas spring placed in a pocket flooded by fluids, used in temperatures not recomended ( 0 C - 100 C) in a proper working enviroment, wrong manipulation of the gas spring. - Consult Azolgas whenever considering special applications or different conditions as described in this document.

370 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 200 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS Puerto de carga Filling port M6 M6 Ø25 CARRERA STROKE L1 ±0.5 L ±0.1 10 80 69 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 15 90 74 25 110 84 38 136 97 200 300 50 160 109 63.5 186.5 122 80 220 139 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... No Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 200 - A04-025 www.azolgas.es FLANGES 371 * 10-2010 mounting: A04 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 200 50 KIT CM 200 50 KIT+PLUG CM 200 50 A04-025

372 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 350 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS Puerto de carga Filling port M6 M8 Ø32 CARRERA STROKE L1 ±0.5 L ±0.1 10 70 58 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 15 80 63 25 100 73 38 126 86 350 525 50 150 98 63 176 111 80 210 128 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... No Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

* 10-2010 CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 350 - A14-032 www.azolgas.es FLANGES -032 373-032 CNOMO - E24.54.815.G mounting: A14 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 350 50 KIT CM 350 50 KIT+PLUG CM 350 50 A14-032

374 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 500 Puerto de carga Filling port M6 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS M8 Ø38 CARRERA STROKE L1 ±0.5 L ±0.1 10 75 63 15 85 68 25 105 78 38 131 91 50 155 103 63 186 121 80 220 138 100 260 158 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 500 750 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... No Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

* 10-2010 CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 500 - www.azolgas.es FLANGES A14-038 A34-038 375-038 -038 CNOMO - E24.54.815.G mounting: A14 A34 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 500 50 KIT CM 500 50 KIT+PLUG CM 500 50 A14-038

376 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CMR 500 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS Puerto de carga Filling port M6 M38x1.5 CARRERA STROKE L1 ±0.5 L ±0.1 15 85 68 25 105 78 38 131 91 50 155 103 63 186 121 80 220 138 100 260 158 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 500 750 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... No Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CMR 500 - E58-038 www.azolgas.es FLANGES 377 mounting: E58 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CMR 500 50 KIT CMR 500 50 KIT+PLUG CMR 500 50 E58-038

378 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 1000 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 2 x M8 Ø50 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 10 105 93 15 115 98 25 135 108 38 161 121 50 185 133 63 211 146 80 245 163 100 295 193 125 345 218 160 415 253 200 495 293 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 1000 1500 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CARRERA STROKE 25 mm CM 1000 - www.azolgas.es FLANGES 379 DIAMETRO DIAMETER 50 mm 145 mm 135 mm 120 mm 100 mm 88 mm AG 750 XCF B11-050 CD 1000 CM 1000 AG 750 GN AG 750 FD CW 1000 B21-050 CNOMO - E24.54.815.G RENAULT - EM24.54.700/F mounting: B11 B21 B51 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1000 50 KIT CM 1000 50 KIT+PLUG CM 1000 50 B11-050

380 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET A14-050 CM 1000 - FLANGES A34-050 * 10-2010 A04-050 CNOMO - E24.54.815.G A24-050 mounting: B11 B21 B51 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1000 50 KIT CM 1000 50 KIT+PLUG CM 1000 50 A14-050

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 1000 - FLANGES 381-050 -050 CNOMO - E24.54.815.G * 10-2010 CNOMO - E24.54.815.G C05-050 B51-050 mounting: B11 B21 B51 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1000 50 KIT CM 1000 50 KIT+PLUG CM 1000 50-050

382 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 1500 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 2 x M8 Ø63 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 10 105 93 25 135 108 38 161 121 50 185 133 63 211 146 80 245 163 100 285 183 125 345 218 160 415 253 200 495 293 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 1500 2250 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

* 10-2010 CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 1500 - A14-063 www.azolgas.es FLANGES A34-063 383 A39-063 mounting: B11 B21 A14 A34 A39 C05 C35 K05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1500 50 KIT CM 1500 50 KIT+PLUG CM 1500 50 A14-063

384 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 1500 - FLANGES B11-063 B21-063 -063 * 01-2011 mounting: B11 B21 A14 A34 A39 C05 C35 K05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1500 50 KIT CM 1500 50 KIT+PLUG CM 1500 50 B11-063

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 1500 - www.azolgas.es FLANGES -063 C05-063 385 C35-063 K05-063 * 10-2010 mounting: B11 B21 A14 A34 A39 C05 C35 K05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 1500 50 KIT CM 1500 50 KIT+PLUG CM 1500 50-063

386 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 2500 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 4 x M8 Ø75 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 10 115 103 25 145 118 38 171 131 50 195 143 63 221 156 80 255 173 100 300 198 125 350 223 160 425 263 200 510 308 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 2500 3750 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 2500 - FLANGES 387 CARRERA STROKE 25 mm DIAMETRO DIAMETER 75 mm 160 mm 145 mm 135 mm 110 mm 95 mm AG 1500 XCF B11-075 CD 2400 CM 2500 AG 1500 GN AG 1500 FD CW 2400 B16-075 RENAULT - EM24.54.700/F CNOMO - E24.54.815.G mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 2500 50 KIT CM 2500 50 KIT+PLUG CM 2500 50 B11-075

388 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 2500 - FLANGES A14-075 A34-075 * 10-2010 A04-075 CNOMO - E24.54.815.G A24-075 mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 2500 50 KIT CM 2500 50 KIT+PLUG CM 2500 50 A14-075

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 2500 - -075 www.azolgas.es FLANGES -075 389 CNOMO - E24.54.815.G CNOMO - E24.54.815.G C05-075 B21-075 RENAULT - EM24.54.700/F mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 2500 50 KIT CM 2500 50 KIT+PLUG CM 2500 50-075

390 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 4000 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 4 x M8 Ø95 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 25 155 128 38 181 141 50 205 153 63 236 171 80 270 188 100 310 208 125 370 243 160 440 278 200 530 328 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 4000 6000 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 4000 - FLANGES 391 CARRERA STROKE 25 mm DIAMETRO DIAMETER 95 mm 170 mm 155 mm 145 mm 120 mm 108 mm AG 3000 XCF B11-095 CD 4200 CM 4000 AG 3000 GN AG 3000 FD CW 4200 B16-095 RENAULT - EM24.54.700/F CNOMO - E24.54.815.G mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 4000 50 KIT CM 4000 50 KIT+PLUG CM 4000 50 B11-095

392 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET A14-095 CM 4000 - FLANGES A34-095 * 10-2010 CNOMO - E24.54.815.G A04-095 A24-095 mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 4000 50 KIT CM 4000 50 KIT+PLUG CM 4000 50 A14-095

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 4000 - FLANGES -095-095 393 CNOMO - E24.54.815.G CNOMO - E24.54.815.G C05-095 B21-095 RENAULT - EM24.54.700/F mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 4000 50 KIT CM 4000 50 KIT+PLUG CM 4000 50-095

394 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 6500 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 4 x M10 Ø120 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 25 165 138 38 191 151 50 215 163 63 241 176 80 275 193 100 315 213 125 375 248 160 450 288 200 540 338 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 6500 9750 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 6500 - FLANGES 395 CARRERA STROKE 25 mm DIAMETRO DIAMETER 120 mm 190 mm 165 mm 152 mm 140 mm 118 mm AG 5000 XCF B11-120 CD 6600 CM 6500 AG 5000 GN AG 5000 FD CW 6600 B16-120 RENAULT - EM24.54.700/F CNOMO - E24.54.815.G mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 6500 50 KIT CM 6500 50 KIT+PLUG CM 6500 50 B11-120

396 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 6500 - A14-120 FLANGES A34-120 * 10-2010 A04-120 CNOMO - E24.54.815.G A24-120 mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 6500 50 KIT CM 6500 50 KIT+PLUG CM 6500 50 A14-120

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 6500 - -120 www.azolgas.es FLANGES -120 397 CNOMO - E24.54.815.G CNOMO - E24.54.815.G C05-120 B21-120 RENAULT - EM24.54.700/F mounting: B11 B16 B21 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 6500 50 KIT CM 6500 50 KIT+PLUG CM 6500 50-120

398 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 10000 CILINDROS CON DIMENSIONES INTERMEDIAS COMPACT HEIGHT GAS SPRINGS 4 x M10 Ø150 Puerto de carga Filling port CARRERA STROKE L1 ±0.5 L ±0.1 25 186 158 38 212 171 50 236 183 63 262 196 80 296 213 100 336 233 125 386 258 160 456 293 200 536 333 Fuerza dan / Force dan (150 Bar) Inicial/Initial Final/Final 10000 15000 Fluido presurizado / Pressure medium... N2 Máx. presión de carga / Max. charging pressure... 150 bar Mín. presión de carga / Min. charging pressure... 20 bar Temperatura de trabajo / Operating temperature... 0-100 C Máx. velocidad del vástago / Max. piston rod speed... 1.6 m/s Recargable / Refillable... Si / Yes Conexión / Connection... Si / Yes Se recomienda una reserva del 10% de la carrera A 10% stroke length allowance is recomended Se fabrican cilindros especiales fuera de catalogo, bajo pedido Special gas spring out of catalog are manufactured to specification request

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 10000 - FLANGES 399 B11-150 B16-150 RENAULT - EM24.54.700/F RENAULT - EM24.54.700/F CNOMO - E24.54.815.G B21-150 B51-150 mounting: B11 B16 B21 B51 B01 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 10000 50 KIT CM 10000 50 KIT+PLUG CM 10000 50 B11-150

400 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET CM 10000 - FLANGES A14-150 A34-150 * 10-2010 A04-150 CNOMO - E24.54.815.G A24-150 mounting: B11 B16 B21 B51 B01 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 10000 50 KIT CM 10000 50 KIT+PLUG CM 10000 50 A14-150

CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET www.azolgas.es CM 10000 - FLANGES -150-150 401 CNOMO - E24.54.815.G CNOMO - E24.54.815.G C05-150 B01-150 mounting: B11 B16 B21 B51 B01 A04 A14 A24 A34 C05 Resorte de gas (Modelo - Fuerza - Carrera) including upper plug CM 10000 50 KIT CM 10000 50 KIT+PLUG CM 10000 50-150

402 www.azolgas.es CUSTOMIZED SERVICE FOR YOUR GLOBAL MARKET NOTAS / NOTES