User's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50



Documentos relacionados
High Voltage Oscilloscope Probe

Non-Contact Phase Rotation Tester

INSTRUCTION MANUAL English / Español

Manual del usuario. Modelos y Calibradores para nivel de sonido

Manómetro para presión diferencial Modelo


ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

Manual del usuario. Termómetro RTD. Modelo con optional RTD sonda* * vendido por separado

Assembly Instructions. Tools required for assembly: Small wrench. Operating Instructions. Cleaning Your KaZAM Bicycle WARNING: WARNING:

Quick Installation Guide TU2-DVIV H/W: V1.0R

Guía de instalación rápida TEG-160WS TEG-240WS

Part No: KTI (Page 1-13) (Pagina 14-26) K-Tool International Wixom, MI 48393

24-Port 10/100Mbps Web Smart PoE Switch with 4 Gigabit Ports and 2 Mini-GBIC Slots TPE-224WS

Manual del usuario. Higro-Termómetro Digital EasyVision. Modelo EA20. Introducción

Guía del usuario. Servicio pesado Manómetro para presión diferencial. Modelo

NOTICE D INSTRUCTION DETECTEUR DE COURANT ET TENSION FRANCAIS

Sierra Security System

Physician s Scale Eye-Level Beam Scale Operation Instructions

Software TRENDnetVIEW Pro. Guía de instalación rápida de TRENDnetVIEW Pro (1)

Video Server. Quick Installation Guide. English, Español

EzFlex Detector de fugas de gas combustible Modelo EZ40

PC USER GUIDE. Read this user guide carefully before using this device. Overview. Battery status indicator

Manual del usuario. Higrómetro sin agujas + Humectación + IR. Modelo MO290

Guía de instalación rápida TE100-P1U

IntesisBox PA-RC2-xxx-1 Panasonic compatibilities

Registrador de Humedad / Temperatura

MODEL EX26603 EX26903 A174821

KM-9738 KARAOKE MIC WITH SPEAKER WIRELESS BT. KM-9738 User Manual KM-9738 Manual del Usuario MICRÓFONO INALÁMBRICO CON PARLANTE BT

CERTIFICADO DE GARANTÍA LIMITADA DE POR VIDA DE FREGADEROS ELKAY

CONTROLADORA PARA PIXELS CONPIX

Guía de instalación rápida TEW-639GR 2.01

Quick start guide.

Extension Cords Extensiones Eléctricas We light your world

Quick Installation Guide TU-S9

FCC Information : Warning: RF warning statement:

150Mbps Micro Wireless N USB Adapter

Manual del usuario. Modelo Foto Tacómetro Láser y de Contacto. Introducción

Guía de instalación rápida TE100-P

Zune 8GB/4GB Start. Iniciar.

Protección modo común

Quick Installation Guide TEG-160WS TEG-240WS H/W: C1

Agustiniano Ciudad Salitre School Computer Science Support Guide Second grade First term

Guía de instalación rápida TEW-691GR 1.01

Table of Contents. Español Antes de iniciar Cómo conectar Cómo utilizar el conmutador... Troubleshooting... Version

Cher client, Toute l équipe COMMENCAL vous remercie d avoir effectué votre commande.

GARAGE DOOR OPENER CONNECTIVITY HUB QUICK START GUIDE

SFD-200-N-B DESPERTADOR-PROYECTOR-CON VOZ. Manual de instrucciones

Passaic County Technical Institute 45 Reinhardt Road Wayne, New Jersey 07470

INSTRUCTION MANUAL English / Español

Quick Installation Guide Internet Setup


CESVA USB DRIVER. M_CUD_v0001_ _ESP_ENG

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module

GUÍA DE USUARIO PC Bienvenidos al mundo Perfect Choice. Antes de comenzar a usar el producto es importante que leas esta guía.

appkbws03 Wireless Multimedia Keyboard Set Black

Manual De Instrucciones. Medidor de Pinza 400A CD/CA RMS Real Modelo

Quick Installation Guide TW100-BRV304

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual DECLUTCHABLE WORM GEAR

Manual del usuario. Termo anemómetro de cazoletas. Modelo AN400

Hard Disk Drive Duplicator Dock USB 3.0 to SATA HDD Duplicator. StarTech ID: SATDOCK22RU3

OPERATING INSTRUCTIONS PIT JACK COD COD GUARANTEE... 7

Termómetro infrarrojo (IR), doble láser

Guía de instalación rápida TPL-303E TPL-303E2K 1.01

Calibrador/Termómetro Microprocesador Modelos A y A

FOR INFORMATION PURPOSES ONLY Terms of this presentation

Quick Installation Guide TEW-624UB H/W:B1.1R

IntesisBox MD-AC-xxx-yy AC indoor unit compatibilities

MANUAL DE USUARIO. Registrador USB. de Humedad y Temperatura TEMPERATURE/HUMIDITY USB DATALOGGER THL1

Guía de instalación rápida TBW-107UB 1.01

Super Mini Retractable Mouse

Servicio de Reclamos Amadeus Guía Rápida

Owner s Manual (English language)

1. Sign in to the website, / Iniciar sesión en el sitio,

Medidor de temperatura y conductividad para trabajo pesado

EP382 EURO-PRO Operating LLC: Boston, MA, Bois Franc, St. Laurent, Quebec H4S 1A7 Tel.: 1 (800) ,

MANUAL DE USO - Línea RGB-IR 1.0/13. /Use Manual - RGB-IR Club 1.0/13

Creating your Single Sign-On Account for the PowerSchool Parent Portal

manual de agua potable y saneamiento Most of the time, manual de agua potable y saneamiento is just instructions regarding how to install the system.

Quick Installation Guide. TEG-224WSplus

2010 Encore Electronics, Inc. All rights reserved.cover

Quick Installation Guide TEW-631BRP

SYSTÈME DE SURVEILLANCE NUMÉRIQUE SANS FIL ACL QUADRUPLE

USB 2.0 INTERNAL MEMORY CARD READER/WRITER USER MANUAL CRW-UINB

Quick Installation Guide Internet Setup

EQUIPO DE CAPTURA DE VIDEO USB 2.0. V2.0 / 0317v

Registrador de datos de humedad y temperatura

Manual del Usuario. Monitor de Nivel de Sonido. Modelo SL120

Quick Installation Guide TPE-224WS

Installation Guide C. Countertop

Quick Installation Guide TWG-BRF114

TYPE SUITABLE FOR INPUT VOLTAGE. 1 ~ 3 leds 1W VAC 2-12 VDC 350 ma IP67 Blanco White FUSCC-4-350T TYPE POWER INPUT VOLTAGE.

Quick Installation Guide TE100-P11 TEW-P11G H/W: V1

Como desempacar el Time Attendant Además de ésta guía, el empaque debe incluír lo siguiente: Time Attendant Quick Install Reference Guide

Voyager Serie 1400g. Guía de inicio rápido. Escáner alámbrico de Captura de Imágenes (Area-Imaging) VG1400-LS-QS Rev A 10/12

Quick Installation Guide TEW-632BRP

Portable esata USB to SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: SATDUPUEGB

Steps to Understand Your Child s Behavior. Customizing the Flyer

VCC-HD2300/HD2300P VCC-HD2100/HD2100P

Name: Credit Requested: $ Address: City/Zip Code: Credit Manager: Address: Fleet Manager: Address:

Transcripción:

User's Guide Humidity + Temperature + Pressure Datalogger Model RHT50

Introduction Congratulations on your purchase of the Relative Humidity / Temperature / Pressure Datalogger; this datalogger measures and stores up to 10,000 readings. The user can easily configure the logging rate, high/low alarm and start-mode. It also downloads the stored data by plugging the module into a PC USB port and running the supplied PC software. Data can then be graphed, printed and exported to other applications. The data logger is supplied with a 3.6V ½ AA lithium battery. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features Datalogger Memory stores 10,000 temperature, humidity and pressure readings Selectable data sampling rate: 1 second to 18 hours Manual and automatic datalogger start Status Indication via Red/Yellow LED and Green LED USB Interface for Set-up and Data Download User-Programmable Alarm Thresholds Long battery life Description 1. USB connector 2. Alarm LED (red/yellow) 3. Record LED (green) 4. Start button 5. Battery cover latch 6. Tripod mount 7. RH, Temperature, Pressure sensors 8. Mounting bracket 2

Operation INSTALLING THE GRAPHING SOFTWARE Install the supplied Windows TM PC Datalogger Software by placing the supplied program disk in the PC s CD-ROM drive. If the installation program does not automatically open and provide on-screen prompts, open and browse the CD-ROM drive, then find and double-click on the SETUP.EXE file included on the program disk. Follow the on-screen prompts to complete the installation. Before running the graphing software, please connect the RHT50 to the PC and install the USB Driver software as described in the next section. INSTALLING THE USB DRIVER Plug the RHT50 into an available USB port on the PC. If this is the first time that the RHT50 has been connected to the particular port on the PC, the following screen will appear: Make sure the program disk is still in the PC CD-ROM drive. Select the recommended installation and follow the on-screen prompts to complete the driver installation. If this is a repeat connection of the RHT50 to the USB port, the driver installation process will be automatically skipped. Refer to the HELP utility in the software program for detailed instructions on using the software to download and process recorded data. The LED status guide provided below is offered for easy reference. 3

LED STATUS GUIDE LEDs Record Alarm Green Red Meaning No LED Logging not started No LED Logging stopped * No LED Battery discharged ** Green flash (single): Logging indication ***** Green flashes (five) Reset Green flashes (six) Start Logging Red double flash every 30 sec. Low battery *** Red single flash Logging, alarm event **** Red flashes (six) Stop logging * Yellow flash every 20 seconds Memory full * Yellow * Connect the datalogger to the PC and download data ** Replace the battery, data will not be lost *** Logging will stop, data will remain in memory **** Occurs if an alarm is exceeded ***** Flash cycle time is set from the software 4

Specifications Range Accuracy Relative Humidity 0 to 20 and 80 to 100% ±5.0% 20 to 80% ±3.5% Temperature -40 to 32 o F and 104 o F to 158 o F -40 to 0 o C and +40 to +70 o C ±3.6 o F/±2 o C 32 o F to104 o F/0 o C to +40 o C ±1.8 o F/±1 o C Pressure 950 to 1050hPa Accuracy: ±0.25%FSO @ (25 o C) Repeatability: ±0.25%Max+±0.3%FSO) Linearity/Hysteresis: ±0.24%FSO Temperature coefficient: ±0.1%FSO Notes: FSO: Full Scale Output 1psi = 68.947 mbar = 0.068947 bar 1 psi = 6894.7 Pa = 68.947 hpa = 6.8947 kpa Resolution Data storage Logging rate Operating temperature Battery type Battery life Dimensions/Weight 0.1%RH, 0.1 o C/F, 0.1hPa 10,000 measurements Selectable sampling interval: From 1 second up to 18 hours -31 to 176 o F (-35 to 80 o C) 3.6V (1/2 AA) (SAFT LS14250, Tadiran TL-5101 or equivalent) 1 year (typ.) depending on logging rate, ambient temperature, & use of Alarm LEDs 4 x 1 x.9 (101 x 25 x 23mm) / 6oz (172g) 5

Battery Replacement It is highly recommended that the battery be replaced every 12 months, or prior to logging critical data. The RHT50 does not lose its stored readings when the battery weakens or when the battery is replaced; the data logging process will however be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to PC. Use only a 3.6V ½ AA lithium battery. Before replacing the battery, remove the datalogger from the PC. Follow the steps in the diagram below for opening the housing and replacing the battery. NOTE: Leaving the RHT50 plugged into the PC USB port longer than necessary will cause some of the battery capacity to be lost. WARNING: Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 6

Warranty (English) EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Product Support Technical Support: support@extech.com -- Calibration and Repairs: repair@extech.com Product specifications subject to change without notice For the latest version of User Guides, Software updates, and other information: www.extech.com (781) 890-7440 Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 ISO9001 Certified Copyright 2010 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 7

Garantía (Español) EXTECH INSTRUMENTS CORPORATION (UNA EMPRESA FLIR) garantiza este instrumento para estar libre de defectos en partes o mano de obra durante un año a partir de la fecha de embarque (se aplica una garantía limitada a seis meses para los cables y sensores). Si fuera necesario regresar el instrumento para servicio durante o después del periodo de garantía, llame al Departamento de Servicio a Clientes al teléfono (781) 890-7440 ext. 210 para autorización, o visite nuestra página en Internet www.extech.com para Información del contacto. Se debe otorgar un número de Autorización de Retorno (RA) antes de regresar cualquier producto a Extech. El remitente es responsable de los gastos de embarque, flete, seguro y empaque apropiado para prevenir daños en tránsito. Esta garantía no se aplica a defectos resultantes de las acciones del usuario como el mal uso, alambrado equivocado, operación fuera de las especificaciones, mantenimiento o reparación inadecuada o modificación no autorizada. Extech específicamente rechaza cualesquier garantías implícitas o factibilidad de comercialización o aptitud para cualquier propósito determinado y no será responsable por cualesquier daños directos, indirectos, incidentales o consecuentes. La responsabilidad total de Extech está limitada a la reparación o reemplazo del producto. La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral, expresa o implícita. Ayuda de producto Soporte Técnico support@extech.com - Reparación / Retornos: repair@extech.com Las especificaciones del producto están sujetas a cambios sin aviso Para la última versión de esta Guía del usuario, actualizaciones de software y otra información www.extech.com (781) 890-7440 Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 Certificado ISO9001 Copyright 2010 Extech Instruments Corporation (una empresa FLIR) Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio. Garantie (Français) EXTECH APPAREILS CORPORATION (Une société FLIR) garantit que cet appareil est exempt de défauts matériels et de fabrication pendant un an à compter de la date d envoi (une garantie limitée de six mois s applique aux capteurs et câbles). Si le renvoi de l appareil pour réparation devient nécessaire durant ou après la période de garantie, contactez le service client au (781) 890-7440 poste. 210 pour autorisation ou visitez notre site Web à l adresse www.extech.com pour obtenir nos coordonnées. Un numéro d autorisation de retour (AR) doit être délivré avant tout retour de produit à Extech. L expéditeur prend à sa charge les frais d expédition, le fret, l assurance et l emballage correct de l appareil afin de prévenir toute détérioration durant le transport. Cette garantie ne s applique pas aux dommages imputables à l utilisateur tel que l usage impropre ou abusif, un mauvais câblage, une utilisation non conforme aux spécifications, un entretien ou une réparation incorrecte, ou toute modification non autorisée. Extech déclinera spécifiquement toute garantie ou qualité marchande ou aptitude à l emploi prévu et ne sera en aucun cas tenu responsable pour tout dommage conséquent direct, indirect, ou accidentel. La responsabilité totale d Extech est limitée à la réparation ou au remplacement du produit. La garantie définie ci-dessus est inclusive et aucune autre garantie, écrite ou orale, n est exprimée ou implicite. Appui de produit Service d assistance technique support@extech.com - Réparations et retours :repair@extech.com Spécifications produit sujettes à modifications sans préavis Pour obtenir la dernière version de ce manuel d utilisation, des mises à jour logicielles et autres informations www.extech.com -(781) 890-7440 Extech Appareils Corporation, 285 Bear Hill Road, Waltham, MA 02451 Certifié ISO 9001 Copyright 2010 Extech Appareils Corporation (une société FLIR). Tous droits réservés, y compris le droit de reproduction, en tout ou en partie, sous quelque forme que ce soit. 8