WCSM. Suggested Installation Equipment (not supplied with kit) Recommended Tyco Electronics Torches. Adjusting the Torch



Documentos relacionados
Cable Breakouts. Clean, lint-free cloths Raychem recommended torch or heat gun

MCK-xV Kit para Conexión de Motor 1000V Retardada a la Flama para Cable de Energía de Bajo Tensión 1/C

MCK-xV. Recommended Tyco Electronics Torches. Suggested Installation Equipment (not supplied with kit) Adjusting the Torch. Safety Instructions

MCK-5-xV 5-8kV Class

HVBT. High Voltage Self-Amalgamating Tape for Round and Rectangular Bus Bars. Product Installation Instructions

Series HVS-1520S Clase 15 KV

HVBT. Recommended Tyco Electronics Torches. Safety Instructions. Adjusting the Torch. Regulator Pressure. General Information. Cleaning the Cable

MRS. Safety Instructions. Suggested Installation Equipment (not supplied with kit) Recommended Tyco Electronics Torches. Adjusting the Torch

MOD-3-HVT MOD 3X, 3Y, 3A, 3B

CRSM Cable Repair Sleeve

HVT Series Terminations 5-35kV Class. High Voltage Termination for Copper Tape, Wire Shield, Lead Sheath and UniShield Cable

HVS-1520S Series. Suggested Installation Equipment (not supplied with kit) Recommended Tyco Electronics Torches. Adjusting the Torch

LVIT. Low Voltage, Heat-shrinkable Bus Insulation Tubing. Product Installation Instructions

MCK and MCK-5. Type L The Type L kit is used, where space permits, to splice in-line connections.

BBIT/BPTM 5-35kV Class

BBIT/BPTM 5-35kV Class

RTA-B002 DIMENSIONS MAXIMUM WEIGHT CAPACITIES. Highest position. Lowest position. Product Size: 22"W x 16"D x 30.5~46.5"H

WOW SECOND SKIN INSTALLATION GUIDE. Steps and recommendations to install and enhance your Second Skin product. WOW SECOND SKIN GUÍA DE INSTALACIÓN

Preassembled Rail Instructions

OWNER'S MANUAL MANUAL DEL PROPIETARIO

ADHESIVE INSTALLATION GUIDE ENGLISH ESPAÑOL PAGE 2 PÁGINA 4

MODEL: F / MODELO: F END TABLE WITH MEDIA STAND & MAGAZINE HOLDER MESA RINCONERA CON ESTANTE & REVISTERO

SUSTITUCIÓN DE TUBOS FLUORESCENTES POR TUBOS DE LEDs CHANGING FLUORESCENT TO LED TUBES

T R A N S TECHNICAL SPECIFICATIONS:

A I RTRONIC. Manual de usuario User Manual.

5. INSTALLATION INSTRUCTIONS 5. INSTRUCCIONES DE INSTALACIÓN

MODEL: N / MODELO: N GAZEBO / GAZEBO

Cambridge Pre-Packaged / Pre-Cut MaytRx Wall Patio and Pub Bistro Table

Car Seat Adapter Adaptador de la silla para el coche

RTA-2706A DIMENSIONS

Light Package Switches Interruptores ligeros del Paquete

Light Package Switches Interruptores ligeros del Paquete

HVS-3520S Series. *UniShield is a trademark of General Cable Technologies Corporation. Recommended Tyco Electronics Torches

INSTA RAIL. Assembly Instruction

Package Contents. Hardware Package. Tools Needed

Cambridge Pre-Packeged / Pre-Cut Olde English Wall Patio Pub & Bistro Table Kit

INSTRUCCIONES DE ENSAMBLAJE.

MT442 MT642 U S E R S M A N U A L

You and Me Designed by Antoni Pallejà Office USER S MANUAL MANUAL DEL USUARIO

Wall Mounted Range Hood System

Enkadrain. Installation Instructions Instrucciones para la Instalación. Toll Free / Línea Gratis: Web:

MINI INDUSTRIAL DUTY DIE GRINDER

Añadir para firmar digitalmente documentos EDE. Add digital signatures to EDE documents

Installation Guide. Green momit

CE23841 MODELO: INSTRUCTION MANUAL WAFLERA MANUAL DEL USUARIO WAFFLE MAKER MODEL: CE23841

1

LOW SPEED RIGHT ANGLE CUT-OFF TOOL

BASE & WALL EASY REACH CABINET 170º Hinge Replacement

car seat adapter adaptador del asiento de automóvil CXBEX/MAXI COSI/NUNA babyjogger.com ASSEMBLY INSTRUCTIONS INSTRUCCIONES DEL ENSAMBLAJE PD349778A

Aluminum Clad Installation Instructions for a Single or Double Door Unit

MANUAL DE INSTRUCCIONES / USER'S GUIDE VD31

MF222 U S E R M A N U A L

MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL

Installation Instructions

Going Home. Medicines. Pain. Diet

MODEL RTA-2018 MODEL RTA-2018

PISTOL NEEDLE SCALER KIT

QUICK CHANGE REVERSIBLE AIR DRILL KIT

Tiding with a double nut all together.

Arm Theraband Exercises: Standing

Read all instructions BEFORE assembly and USE of product. KEEP INSTRUCTIONS FOR FUTURE USE.

Instruction Manual. Safety Warning and Precautions

ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

FAST KILLER FUNGUS CONTROL DUALACTION KILLS HARMFUL INSECTS ON CONTACT CONTROLS AND PRE VENTS LISTED MA JOR L AWN DISE ASES AND FUNGUS

Ready-To-Finish Fire Pit Cabinet Assembly Instructions

FLEXO MERCURIO INSTRUCCIONES INSTRUCTIONS

FLEXO URANO INSTRUCCIONES INSTRUCTIONS

RTA-3325 DIMENSIONS MAXIMUM WEIGHT CAPACITIES. Product Size: 60"W x 23.5"D x 35"H

MINT. Instructions / Instrucciones ART. D020AU+F021BU ART. D013AU+F013BU ART. D013AU+F011BU ART. F045BU

Pneumatic Desoldering Module

Marcando la diferencia. Making a difference. TERMINALES PREAISLADOS

Aluminum Clad Installation Instructions for a Door Unit with Single or Double Sidelites

BBIT/BPTM Clase 5-35kV

5. INSTALLATION INSTRUCTIONS 5. INSTRUCCIONES DE INSTALACIÓN

Organización de Aviación Civil Internacional GRUPO DE EXPERTOS SOBRE MERCANCÍAS PELIGROSAS (DGP) VIGESIMOQUINTA REUNIÓN

Delivery & Installation Pointer

JUEGOS DE SISTEMA DE DUCHA COMERCIALES: 1.5 gpm y 2.5 gpm

Empalme recto de contracción en frío

Cambridge Pre-Packaged / Pre-Cut MaytRx Wall Mailbox

CUERPO EN T CLASE 35 kv 600 A INSTRUCTIVO DE INSTALACION Y OPERACION

Guía de instalación rápida TFM-561U

Cambridge Pre-Packaged / Pre-Cut Olde English Wall Mailbox

Prueba de práctica Matemáticas 10 grado

Urine Sample-Female (Clean Catch)

RIGHT ANGLE DIE GRINDER

Meijer.com A

Astragal Mortise Lock Replacement

INSTALLATION INSTRUCTIONS

EQUIPO DE CAPTURA DE VIDEO USB 2.0. V2.0 / 0317v

How to connect a PC drive to a Sanyo Wavy (Spanish and english version) External connection of 3" drive to SVI 738

MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL

ASSEMBLY INSTRUCTIONS

WALL MOUNTING REQUIRED

Arm Theraband Exercises: Lying

Manual de Exportación de Certificados Digitales

Documentación técnica: Desmitificar los métodos de prueba de fibra: de regreso a lo básico

ASSEMBLY INSTRUCTIONS 3-SEAT CUSHIONED SWING WITH CANOPY FR / FG INSTRUCCIONES DE MONTAJE HAMACA DE 3 ASIENTOS CON TECHO DE LONA

8 BIN WOODEN STORAGE ORGANIZER ORGANIZADOR DE 8 CAJONES DE TELA

Transcripción:

WCSM Heavy-Wall Tubing for 1/C Low-Voltage Power Cables Suggested Installation Equipment (not supplied with kit) Cable preparation tools Tyco Electronics P63 cable preparation kit or cable manufacturer approved solvent Clean, lint-free cloths Non-conducting abrasive cloth, 0 grit or finer Electrician's tape Connector(s) and installation tools Tyco Electronics recommended torch Safety Instructions Warning: When installing electrical power system accessories, failure to follow applicable personal safety requirements and written installation instructions could result in fire or explosion and serious or fatal injuries. To avoid risk of accidental fire or explosion when using gas torches, always check all connections for leaks before igniting the torch and follow the torch manufacturer's safety instructions. To minimize any effect of fumes produced during installation, always provide good ventilation of confined work spaces. As Tyco Electronics has no control over field conditions which influence product installation, it is understood that the user must take this into account and apply his own experience and expertise when installing product. Recommended Tyco Electronics Torches Install heat-shrinkable cable accessories with a "clean burning" torch, i.e., a propane torch that does not deposit conductive contaminants on the product. Clean burning torches include the Tyco Electronics FH-2629, FH-26 (uses refillable propane cylinders) and FH-261A (uses disposable cylinder). Adjusting the Torch Adjust regulator and torch as required to provide an overall - inch bushy flame. The FH-2629 will be all blue, the other torches will have a 3- to 4-inch yellow tip. Use the yellow tip for shrinking. Regulator Pressure FH-261A Full pressure FH-26 psig FH-2629 psig General Shrinking Instructions Apply outer 3- to 4-inch tip of the flame to heat-shrinkable material with a rapid brushing motion. Keep flame moving to avoid scorching. Unless otherwise instructed, start shrinking tube at center, working flame around all sides of the tube to apply uniform heat. To determine if a tube has completely recovered, look for the following, especially on the back and underside of the tube: 1. Uniform wall thickness. 2. Conformance to substrate. 3. No flat spots or chill marks. 4. Visible sealant flow if the tube is coated. Note: When installing multiple tubes, make sure that the surface of the last tube is still warm before positioning and shrinking the next tube. If installed tube has cooled, re-heat the entire surface. 1

Table 1 UL Listed Connector/Tubing Selection Guide Cable Size Coated Minimum* Tubing Burndy Copper Connections Die Index Color Code 6 4 2 1 1/0 2/0 3/0 4/0 0 300 350 400 500 600 750 00 00, /4 /4, 20/6 20/6 20/6,33/ 33/ 33/ 51/ 51/, YSV- YSV- YSV- YSV-CL YSV-CL YS4C-L YS2C-L YS1C-L YS-L YS26-L YS-L YS2-L YS29-L YS30-L YS31-L YS32-L YS34-L YS36-L YS39-L YS40-L YS44-L 11 17 1 19 20 22 24 346 375 34 29 324 470 399 472 473 Table 2 General Use Selection Guide Catalog Number Cut Piece Catalog Number 00V Cable Use Range(AWG/kcmil) General Use Range (Min-Max) Coated, Cut Pieces WCSM--0-S WCSM--00-S WCSM-/4-00-S WCSM-20/6-0-S WCSM-20/6-00-S WCSM-33/-2-S WCSM-33/-00-S WCSM-43/-00-S WCSM-51/-300-S WCSM-51/-00-S WCSM--300-S WCSM--00-S WCSM-5/30-00-S WCSM-0/40-00-S (2mm) (2mm) (229mm) " " Uncoated, Spooled WCSM--A/U WCSM-/4-A/U WCSM-20/6-A/U WCSM-33/-A/U WCSM-43/-A/U WCSM-51/-A/U WCSM--A/U WCSM-5/30-A/U WCSM-0/40-A/U #-# #-# #-#6 1/0-350 600-00 600-00 00-50 00-00 0.-0.30" (4-mm) 0.-0.30" (4-mm) 0.20-0.45" (5-11mm) 0.40-0.95" (-24mm) 0.40-0.95" (-24mm) 0.50-1.30" (-33mm) 0.70-1.75" (1-44mm) 0.70-1.75" (1-44mm) 0.95-2.30" (24-5mm) 0.95-2.30" (24-5mm) 1.30-3." (33-79mm) 1.75-4." (44-4mm) 2

1. Product selection. Check kit selection with the dimensions given in Tables 1 and 2. Use Table 1 for UL applications Use Table 2 for General Use applications. Use coated tubing for sealed, electrical splicing. Uncoated tubing should be used for non-sealed applications only. 2. Cut coated WCSM tubing to required length. Note: For UL applications, see Table 1 for required length. Connector Dimension A Connector Cut of WCSM + Dimension "A" up to (2mm) and over 5" (7mm) Cut the WCSM tubing using a sharp knife or heavy scissors. Cut must be smooth, without nicks or notches. 676 3. Cutback insulation; clean cables. Using an oil-free solvent, clean the cables as shown. " Clean " 67 4. Place tube over clean cable; install connector. Protect tube from end of conductor as it is placed over the cable end. Clean Install connector per manufacturer's instructions. After installation, clean and deburr connector. 62 5. Center tube over splice; shrink in place. Center WCSM tubing over splice. Working the torch with a smooth brushing motion around the tube, begin shrinking at the center of tube (1), After center portion shrinks, work torch as before toward one end (2), then to the opposite end (3) until completely recovered. 6. Inspect completed splice. Properly installed tube will be smooth and conform to the connection. Adhesive will be visible at both ends. Note: Allow to cool before moving or placing in service. 2 1 3 63 64 3

Instructivo de Instalación WCSM Tubo Termocontráctil de Pared Gruesa con Adhesivo Termoactivado para Aislamiento de Empalmes en Baja Tensión. 4

Instrucciones Generales Equipo Sugerido de Instalación (no se suministra con el equipo) Herramientas de preparación de cables Trapos limpios libres de peluzas Soplete recomendado por Raychem Sopletes Recomendados por Raychem Instale los accessorios termocontráctiles con un soplete de flama limpia, ejemplo: un soplete de propano que no deposite contaminantes conductivos en el Equipo de preparación de cables Raychem P63 o solvente aprobado por el fabricante Cinta de electricista producto. Los sopletes de flama limpia incluyen al Raychem FH-2609, Fh-2629 (usa cilindros de propano recargables) y FH-26Al (usa cilindros desechables). Tela o papel abrasivo, no-conductivo, de fineza 0 o más fina Conector(es) y herramientas de instalación Instrucciones de seguridad Advertencia: Cuando se instalen los accesorios del sistema de energía eléctrica, el no seguir los requerimientos personales de seguridad y las instrucciones escritas referente a la instalación, podría dar como resultado un incendio o una explosión y causar serios o fatales perjuicios. Para evitar riesgo de fuego accidental o de explosión, cuando se utilicen sopletes de gas, siempre revise todas las conexiones por fugas, antes de encender el soplete y siga las instrucciones de seguridad del soplete. Para minimizar cualquier efecto de humo producido durante la instalación, provéase siempre de una buena ventilación en el lugar de trabajo. Como Raychem no controla todas las condiciones que pueden incfuir en la instalación del producto en campo, queda entendido que el usuario debe tomar esto en cuenta y aplicar su propia experiencia y práctica cuando instale el producto. Ajustando el soplete Ajuste el regulador y el soplete como se requiere, para asi proporcionar una flama espesa de un total de pulgadas. En el FH-2629 la flama será toda azul, los otros sopletes tendrán un extremo amarillo de 3 a 4 pulgadas. Use el extremo amarillo para la termocontracción. Presión del regulador FH-26A1 Presión completa FH-2609 5 psig FH-2629 psig Limpieza del Cable Use un solvente adecuado como el provisto en el kit P63. Asegúrese de seguir las instrucciones del producto. Un descuido puede provocar que el producto falle. Instrucciones Generales de Termocontracción Aplique el extremo exterior de 3 a 4 pulgadas de la flama, al material termocontractil al calor con un rápido movimiento de cepillado. Mantenga la flama moviéndose para obtenér una termocontracción uniforme y evitar el chamusqueo. 1. Selección del Producto Verifique la selección del kit con las dimensiones dadas en las tablas 1 y 2. Use la Tabla 1 para aplicaciones de acuerdo a UL. Algunos solventes nuevos no se evaporan rapidamente y necesitan ser removidos con un paño limpio y libre de peluzas. De no ser así, pueden provocarse cambios en la resistividad volumétrica del sustrato o dejar residuos en la superficie. A menos que se le instruya de hacerlo distinto, comience a termocontraer el tubo desde el centro, trabajando la flama alrededor de todas las partes del tubo para aplicar un calor uniforme. Para determinar si el tubo se ha instalado corarectamente obsérvelo especialmente en la parte de atrás: l.-grosor uniforme de las paredes. 2.-Confomación de los substratos. 3.-Sin puntos planos o marcas frías. 4.-Flujo sellador visible si el tubo esta cubierto. Use la Tabla 2 para aplicaciones de uso general. Use tubos termocontráctiles con adhesivo en empalmes eléctricos sellados. Los tubos sin adhesivo solo deben ser usados donde no se requiera sello. Siga cuidadosamente las instrucciones del fabricante. Nota: Cuando se instalen tubos múltiples, asegúrese de que la superficie del último esté todavía caliente, antes de acoplar y encoger el siguiente tubo. Si instala el tubo en frio, recaliente la superfie entera. 5

Tabla 1- Guía de Selección para Conector y Tubo Termocontráctil Calibre del Conductor con Adhesivo Longitud Minima* del Tubo Conector de Cobre Burndy Indice Codigo de Color 6 4 2 1 1/0 2/0 3/0 4/0 0 300 350 400 500 600 750 00 00, /4 /4, 20/6 20/6 20/6,33/ 33/ 33/ 51/ 51/, YSV- YSV- YSV- YSV-CL YSV-CL YS4C-L YS2C-L YS1C-L YS-L YS26-L YS-L YS2-L YS29-L YS30-L YS31-L YS32-L YS34-L YS36-L YS39-L YS40-L YS44-L 11 17 1 19 20 22 24 346 375 34 29 324 470 399 472 473 * Estas longitudes son minimas para conectores de cobre. Tabla 2- Guía de Selección de Uso General Número de Catálogo Con Adhesivo Coated, Cut Pieces WCSM--0-S WCSM--00-S WCSM-/4-00-S WCSM-20/6-0-S WCSM-20/6-00-S WCSM-33/-2-S WCSM-33/-00-S WCSM-43/-00-S WCSM-51/-300-S WCSM-51/-00-S WCSM--300-S WCSM--00-S WCSM-5/30-00-S WCSM-0/40-00-S Longitud Cortada (2mm) (2mm) (229mm) " " Número de Catálogo Sin Adhesivo Uncoated, Spooled WCSM--A/U WCSM-/4-A/U WCSM-20/6-A/U WCSM-33/-A/U WCSM-43/-A/U WCSM-51/-A/U WCSM--A/U WCSM-5/30-A/U WCSM-0/40-A/U Rango de Aplicación Cable Hasta 00V (AWG/kcmil) #-# #-# #-#6 1/0-350 600-00 600-00 00-50 00-00 Rango para Uso General (Min-Max) 0.-0.30" (4-mm) 0.-0.30" (4-mm) 0.20-0.45" (5-11mm) 0.40-0.95" (-24mm) 0.40-0.95" (-24mm) 0.50-1.30" (-33mm) 0.70-1.75" (1-44mm) 0.70-1.75" (1-44mm) 0.95-2.30" (24-5mm) 0.95-2.30" (24-5mm) 1.30-3." (33-79mm) 1.75-4." (44-4mm) 6

2. Corte del WCSM con Adhesivo a la longitud requerida. Nota: Para aplicaciones de acuerdo a UL, vea la Tabla 1. Longitud del Conector Dimensión A Hasta 6 (2mm) 6 en adelante 5" (7mm) Corte el WCSM usando una navaja afilada o unas tijeras grandes. El corte debe ser suave y parejo. Longitud Cut del Corte of WCSM Longitud Connector del + Dimension Dimensión Conector "A" A 676 3. Corte del Aislamiento; limpie los cables. Usando un solvente libre de aceite, limpie los cables como se muestra. " Limpie Clean " 67 4. Coloque el tubo sobre el cable limpio; Instale el conector. Limpie Clean Proteja el tubo mientras se coloca sobre el final del cable. Instale el conector de acuerdo a las instrucciones del fabricante. Después de la instalación limpie y lije el conector. 62 5. Centre el tubo sobre el empalme y contraigalo. Centre el WCSM sobre el empalme. Trabaje la antorcha con un movimiento suave de brocha alrededor del tubo, empiece a contraer al centro del tubo (1). Después de contraer la parte central del tubo, trabaje la antorcha hacia un extremo (2), y después hacia el otro (3) hasta contraer completamente. 6. Inspección del empalme terminado. El tubo correctamente instalado estará suavemente conformado a la conexión. El adhesivo será visible en ambos extremos. Nota: Permita que se enfríe antes de mover o poner en servicio. 2 1 3 63 64 7