Effective 7/5 CAUTION DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH, SEVERE PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING. ADVERTENCIA NO INTENTE INSTALAR O LLEVAR A CABO TRABAJOS DE MANTENIMIENTO EN EL EQUIPOMIENTRAS TENGA ENERGIA. EL CONTACTO CON EQUIPO CON ENERGIA PUEDE PROVOCAR LA MUERTE O LESIONES PERSONALES SEVERAS. ANTES DE PROCEDER, VERIFIQUE SIEMPRE QUE NO HAYA VOLTAJE PRESENTE. A_ A_ A_ A_ Attach endcap. Maximun breaker rating 5 amps continuous. Denominación máxima del interruptor 5 amperios continuo. Coloque la tapa en el extremo Insert screws and washers. Inserte los tornillos y arandelas dentro de los retenedores. 4 Tighten breaker screws. Insert unit into breaker Coloque la unidad en el interruptor Apriete los tornillos del interruptor. Reset Unit 4-8 in/lb (.8-4. N.m) 4-8 pulg./lb..56 in (.969mm).56 pulg.
IL000E Effective July 05 Remove secondary cover. Remueva la tapa secundaria. 5 Insert push bar into RCD window and 7 rotate mechanical accessory into pocket. Inserte la barra en la ventana del RCD y rote el accesorio dentro de la cavidad (abertura). 6 Insert push bar into mechanical accessory. Inserte la barra en el accesorio mecánico. 8 Replace secondary cover, reset unit and latch breaker. Reemplace la tapa secundaria y opere el interruptor. 9 T Torque secondary cover mounting screws 0- in lb (. -.5 Nm). Apriete los tornillos de la tapa secundaria a un torque de 0- pulg. lb. (. -.5 Nm). Test by pushing push-to-trip button. Pruebe la unidad presionado el boton de disparo. 0 Reinicie la unidad y cierre el interruptor. Reset unit and latch breaker. EATON CORPORATION www.eaton.com
IL000E Effective July 05 Attach accessories. Coloque los accesorios. POSITION OF THE TOGGLE HANDLE OFF/RESET POSITION OF THE PROTECTOR RESET BUTTON (YELLOW) ON POSITION OF THE PROTECTOR BELL ALARM ORANGE BLUE GREEN ON ON ORANGE BLUE GREEN TRIPPED TRIP ORANGE BLUE GREEN Customer provided contact. Contacto provisto por el cliente Orange Blue Green Black BELL ALARM 50% I G Remote Trip (A - 50 V ~ ) (0.A - 50 V ~ ) (0.A - 50 V ~ ) Black White White Accessory Wires State of bell alarm contacts as a function of cirucit breaker and protector. Estado de los contactos de la alarma de timbre como una función de interruptor de circuito y protector. 50% IG (or 50% I n) (Indicates 50% of leakage value has been reached) 50% IG (o 50% I n) Indica que 50% del valor defuga fue alcanzado) Test Button Boton de prueba Status Light operation) Push-To-Trip Button Boton de disparo Push to Trip Ground Fault Protector Cat. ELEBN45W S# 68D907G0 In 5A 4 POLE 0 480 V 50/60 Hz Class TEST C.B. Acc. 560U 50% I G STATUS Luz para indicacion del estado (parpadea para indicar operacion apropiada) Reset Button Boton de reinicio Terminal block access (4-pole only) Acceso al bloque de terminal (4 polos solamente) t (s) o t) adjustment Adjuste de t(seg.) (o t) RESET t (s) I G (A) 0.5 0. 0. 0.06 0.5 0. Inst. 0.0 0 NOTICES: - Terminals if used must be aluminum 0.0 Inst. TA5EF or TA50EF (CU-AL). - See breaker for terminal torque. - See instruction sheet for high voltage tests. - For use on Series G, E-Frame Circuit Breaker, Switch, Motor Circuit Protector. Hazardous voltage can cause severe injury or death. In reverse-feed applications GFP (Ground Fault Protector) is energized when breaker handle is in any position. Disconnect all power before installing or removing GFP. Do not remove cover from GFP. CU-AL 68 C7 H04 I G (or I n) adjustment Adjuste del IG (o I n) EATON CORPORATION www.eaton.com
IL000E Effective July 05 4 Product Operation a. 50% Earth Leakage setting detected, LED and contacts change state. b. 00% Earth Leakage setting detected, the module trips the circuit breaker via mechanical interlock. c. Reset button on earth leakage module extends, indicating trip due to earth leakage current. d. Bell Alarm Auxiliary NO/NC contact in module changes state. a. Depress Rest button on module (if tripped on earth leakage). This will reset the mechanical interlock allowing the circuit breaker to be reset. b. Reset circuit breaker. a. Depress test button to test earth leakage circuit. b. The module trips circuit breaker via mechanical interlock. c. Reset button on earth leakage module extends. d. Bell Alarm Auxiliary NO/NC contact in module changes state. a. Customer supplied signal energized (dry contact closer). b. The module trips the circuit breaker via mechanical interlock. c. Reset button on earth leakage module extends. d. Bell Alarm Auxiliary No/Nc contact in module changes state. a. Se detecta 50% de Falla a Tierra, el LED y contactos cambian de estado. a. Se detecta 00% de Falla a Tierra, el modulo dispara el interruptor de circuito por medio del enlace mecánico. b. El botón de reajuste en el modulo de fallo a tierra se extiende, indicando que hubo un disparo debido a un fallo de corriente a tierra. c. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado a. Presione el botón de reajuste en el modulo (si se disparo debido a falla a tierra). Esto reajustara el enlace mecánico lo que permitirá que el interruptor de circuito pueda ser reajustado. b. Reajustar el interruptor de circuito. a. Presione el botón de prueba para probar el circuito de fallo a tierra b. El modulo dispara el interruptor de circuito por medio del enlace mecánico. c. El botón de reajuste en el modulo de fallo a tierra se extiende. d. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado a. Señal energizada suplida por el cliente (contacto seco cercano) b. El modulo dispara el interruptor de circuito por medio del enlace mecánico. c. El botón de reajuste en el modulo de fallo a tierra se extiende. d. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado 5 FRAME TYPE WIRE TYPE WIRE SIZE TERMINAL CATALOG TORQUE AWG mm² MATERIALS NUMBER Lb. In. Nm EG-Frame Cu/Al 4-0.5-6 Aluminum TA5EF* 5 4.0 EG-Frame Cu/Al.6-/0 6-95 Aluminum TA50EF 80 9.0 *Standard collars mounted on ground fault/earth leakage. 6 TIPO DE TIPO DE TAMANO DE ALAMBRE MATERIALS NUMERO TORSION MARCO ALAMBRE DE LA DE AWG mm² TERMINAL CATALOGO Lb. In. Nm MARCO EG Cu/Al 4-0.5-6 Aluminio TA5EF* 5 4.0 MARCO EG Cu/Al.6-/0 6-95 Aluminio TA50EF 80 9.0 *Conectores estándares montados en el dispositivo falla a tierra/fuga a tierra 4 EATON CORPORATION www.eaton.com
IL000E Effective July 05 7 8.587.97.80.000.000.490.980 4 POLE.980 POLE.000 5.500 0.56.959.897.740.754.00.547.58 8.587.97.80.490.000.000.980 4 POLE.980 POLE.500 0.56 EATON CORPORATION www.eaton.com 5
IL000E Effective July 05 Eaton Corporation Electrical Sector 000 Cherrington parkway Moon Township, PA 508 United States 877-ETN-CARE (877-86-7) Eaton.com 05 Eaton Corporation All Rights Reserved Printed in Dominican Republic Publication No. IL000E July 05 Eaton is a registred trademark of Eaton Corporation. All other trademarks are property of their respective owners. 6 EATON CORPOR ATION www.eaton.com