Installation Guide. L31227 (94130007) Rev 6/10. Installation Instructions for the ILAS III Valve



Documentos relacionados
Installation Guide. L31227 ( ) Rev. 11/17. Installation Instructions for the ILAS-III Valve

ASSEMBLY DRAWING / SPARE PARTS

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual DECLUTCHABLE WORM GEAR

SYSTEM INSTALLATION MANUAL MANUAL DE INSTALACIÓN

EP-2906 Manual de instalación

Process Control Work Instructions Control de Procesos Instrucciones de Trabajo. for / para

MANUAL DE INSTRUCCIONES / USER'S GUIDE VD31

Read all instructions BEFORE assembly and USE of product. KEEP INSTRUCTIONS FOR FUTURE USE.

KMR SCA-05 Mounting Instructions Instrucción de Montaje Instruções de Montagem

Instrucciones de montaje

INSTALLATION INSTRUCTIONS

2008 Series Hemodialysis Machine Operator s Manuals Addendum for Concentrate Connection

KAPTIV-CS. Purga capacitiva electrónica 06/13

ANTENA ELECTRICA AM/FM

ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

Válvulas (blanco / pulgadas) Valves (white / inch) Reguladores de caudal Control valves. Características. Features

DEPARTAMENTO DE CAPACITACION. Gerente de Capacitación Ing. O. Eduardo Reynoso

MANUAL DE INSTALACION PARA EL PANEL DUCHA DE LUJO EN ACERO INOXIDABLE. OLS 7003A

Installation Guide. Green momit

Manual de Servicio del Propietarios serie 503 y 504 SISTEMA DE FLUXÓMETRO - TANQUE

Puede pagar facturas y gastos periódicos como el alquiler, el gas, la electricidad, el agua y el teléfono y también otros gastos del hogar.

ROCK N STEREO SOUND DESK

I N S T R U C C I O N E S D E M O N TA J E Y N O R M A S D E S E G U R I D A D PORTABICICLETAS SAFFIER IV SAFFIER III

car seat adapter adaptador del asiento de automóvil CXBEX/MAXI COSI/NUNA babyjogger.com ASSEMBLY INSTRUCTIONS INSTRUCCIONES DEL ENSAMBLAJE PD349778A

T R A N S TECHNICAL SPECIFICATIONS:

Sierra Security System

Conditioning Exercises: Standing

Guía del usuario de KIP sobre el estado de la impresora Instalación y guía del usuario de KIP sobre el estado de la impresora

Importador: ARGENTRADE S.R.L. CALLE 514 NO. 2050, (1901) RINGUELET LA PLATA, BUENOS AIRES, ARGENTINA

AYERBE INDUSTRIAL DE MOTORES, S.A. MOTOCOMPRESOR AY-300 H AY-300 KT AY-600 H AY-600 KT AY-800 H (MANUAL INSTRUCCIONES)

INSTRUCCIONES DE ENSAMBLAJE.

La Video conferencia con Live Meeting

The Bonded Flange Center Drain Series are intended for use with the following waterproofing methods:

Car Seat Adapter Adaptador de la silla para el coche

A W. Product Label Identification. Etiqueta de identificación del producto. Andersen

π H-4694, H-4695 RIPACK HEAT GUN EXTENSION ATTACH EXTENSION uline.com

Artefacto de iluminación para exteriores

SIMILAC ADVANCE Mixing Instructions for Concentrating 20 calorie per ounce formula. To make 22, 24, 27, and 30 kcal/oz. formula

BAT/ Regenera los vapores en líquido - Altura adaptable - Conexión Push-in. BAT/ Kit 24V. BAT/ Kit 36 V. BAT/ Kit 48 V

Zune 8GB/4GB Start. Iniciar.

RTA-B002 DIMENSIONS MAXIMUM WEIGHT CAPACITIES. Highest position. Lowest position. Product Size: 22"W x 16"D x 30.5~46.5"H

INSTRUCCIONES DE INSTALACIÓN Panel de ducha

THERMAL SWITCH AND SOLENOID VALVE INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA LA INSTALACIÓN DE LA VÁLVULA SOLENOIDE Y DEL INTERRUPTOR TÉRMICO

INSTRUCTIVO DE OPERACIÓN DE LA OLLA ESTERILIZADORA

Specifications, Installation, and Operating Instructions GrowerSELECT 230 VAC Replacement Feed Sensor With Heating Element HS09

Instructivo de uso y cuidado del Aplicador de Implantes Lapisa. Productos Destacados

Vidrio Industrial POBEL, S.A.

MANUAL EASYCHAIR. A) Ingresar su nombre de usuario y password, si ya tiene una cuenta registrada Ó


Model/Modelo: SR42UBEVS

ENGLISH ENGLISH EASY SET ALARM

MODEL: / MODELO: COMPUTER DESK ESCRITORIO DE COMPUTADORA

CONTROLADOR DE CARGA PARA PANELES SOLARES 24V 20A CON DESCONECCION POR BATERÍA BAJA

INSTRUCTION MANUAL WATER DISPENSER MODEL: CE29101

Kit de Alarma de Seguridad - NVR

GRACIAS POR PREFERIR COCHES MOMA INDICE. Advertencias. Configuración. Abrir Coche. Ensamble rueda delantera. Ensamble ruedas traseras.

Portal para Padres CPS - Parent Portal. Walter L. Newberry Math & Science Academy Linda Foley-Acevedo, Principal Ed Collins, Asst.

Actuadores Neumáticos Tipos - PN 5700 y PN 6700 Instrucciones de Instalación y Mantenimiento

24-Port 10/100Mbps Web Smart PoE Switch with 4 Gigabit Ports and 2 Mini-GBIC Slots TPE-224WS

PROCEDIMIENTO DE CARGA DE HELIO LIQUIDO EN EL RMN-600 MHZ DE ROSARIO

MANUAL DE INSTRUCCIONES PARRILLA BARBACOA (18 ) ED-4047BQ

EN / ES Airtribune Live tracking Instructions


WL1003 NEW AUTOMÁTICO

Manual de Presurizadoras LÍNEA ZERO.

Bronze Valves válvulas de bronce

You and Me Designed by Antoni Pallejà Office USER S MANUAL MANUAL DEL USUARIO

Manual de operación y mantenimiento para los controladores de la bomba jockey serie FDJ de EATON

MODEL: F / MODELO: F END TABLE WITH MEDIA STAND & MAGAZINE HOLDER MESA RINCONERA CON ESTANTE & REVISTERO

MANUAL DE INSTRUCCIONES

Creating your Single Sign-On Account for the PowerSchool Parent Portal

ADVERTENCIA: Instrucciones de seguridad importantes. Es importante para la seguridad de las personas seguir estas instrucciones. Consérvelas.

Ready. Set. Go. Vonage Box. Quick Start Guide

OWNER'S MANUAL MANUAL DEL PROPIETARIO

Active Range of Motion Exercises: Wrists, Elbows, Forearms and Shoulders

Retrofit Brake Activation Assembly on Empath Recliner

INSTALLATION INSTRUCTIONS FOR PART B APPLICATIONS 2010 HYUNDAI TUCSON

Como desempacar el Time Attendant Además de ésta guía, el empaque debe incluír lo siguiente: Time Attendant Quick Install Reference Guide

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module

Installation Instructions Front Floor Liner

Flashcards Series 3 El Aeropuerto

CONTROLADORA PARA PIXELS CONPIX

appkbws03 Wireless Multimedia Keyboard Set Black

BAI-220 AURICULAR INALÁMBRICO

CALENTAMIENTO SOLAR DE PISCINA

Wear It Right Wearing your elastomeric full face, 4 strap respirator

Active Leg Range of Motion Exercises: Lying

ÍNDICE / INDEX A.- INSTRUCCIONES DE MONTAJE / ASSEMBLY INSTRUCTIONS B.- INSTRUCCIONES DE DESMONTAJE / DRAWER DISMANTLING INSTRUCTIONS

CLUTCH INSTALLATION TIPS 14-2 Plate and Plate Spicer Style Clutches

LED Strobe Panel - Manual

MANUAL DEL CONDUCTOR AUTOBUS

Sistema electrónico de control de presión GUÍA DE INSTALACIÓN

FCC Information : Warning: RF warning statement:

Illustrated Parts List Lista de Piezas

Silla Salvaescaleras. Una solución sencilla para ayudar a superar escaleras a personas con movilidad reducida

GUÍA DE USUARIO USER GUIDE 2.1 Multimedia Speaker System Design Line APPSP2102

2011 Hyundai Sonata

CESVA USB DRIVER. M_CUD_v0001_ _ESP_ENG

MANUAL RELOJ DE CONTROL CORRESPONDENCIA

LLAVE DE AGUA CÓMO INSTALAR?

Transcripción:

General Information The ILAS III Valve is used for the lowering and lifting of one or multiple axles on an air ride suspension depending on the load applied to the vehicle. Installation Guide L31227 (94130007) Rev 6/10 Assembly Use the provided holes to install the ILAS III Valve. Make sure the valve is mounted in a location that is protected from water on the road and high pressure cleaning. The fittings on the valve should point downward. Refer to Figure 1 and Figure 3. Note: If a high pressure washer is used to clean the vehicle, a distance of at least 50cm (20 ) should be used. The control button (manual version) should be easily accessible and not protrude over the edge of the vehicle when pulled out. The valve should also be protected from unintentional activation. If the valve will be painted or coated, avoid painting the exhaust vent hole and rubber boot for the control button (manual version). Check and record the lowering pressure on the valve or in an area visible from the lift axle(s). Port description: 1 = Supply 11 = Suspension Air Bags 21,22 = Lift Axle Suspension Air Bags 23 = Lift Bags 3 = Exhaust Warning: Keep area of lift axle clear. The axle(s) will automatically lower when the lowering pressure is reached. 90555293 90555288 Installation Instructions for the ILAS III Valve Part 90555288 90555293 Number Fully Automatic Manual Lift Lower Axle Lift Axle Manual Operation Port Fitting Size Automatically based on Ps1 setting and load of vehicle Automatically based on Ps2 setting and load of vehicle With use of manual override components Automatically based on Ps1 setting and load of vehicle Manually with use of the control button With use of control button 3/8 PTC 3/8 PTC

Installation Instructions for the 90555293 (Manual Lift) The lift axle(s) automatically lower when the vehicle is loaded. The control button is then used to raise the lift axle when the vehicle is unloaded. When the vehicle is unloaded, the control button can be pull out to bring the axle(s) down manually. NOTE: To determine the desired Ps1 pressure, connect gauge to air spring line and load the vehicle as desired for lowering the axle. The Ps1 pressure can be adjusted to the desired pressure. Functional Check for Valve 1. Connect gauge and regulator to port 11 2. Connect pressure gauge to test port (Metric M16x1.5 threaded fitting). 3. Verify current Ps1 setting by setting the regulated pressure into the 11 port to 80 psi. 4. Watch for the point on the test port gauge that the valve exhausts and triggers the lowering of the axle(s). 5. Relieve pressure from test port. The ILAS III Manual is factory set at 62 psi for Ps1. It is important when making an adjustment to the Ps1 setting that the adjustment is made from a higher Ps1 setting to a lower Ps1 Setting. If this is not followed then the Ps1 will be triggered before the adjustment can be made. The Ps1 can be set between 44 and 76 psi. Setting the Control Pressure Ps1 1. Set the desired pressure for lowering the lift axles using the regulator in port 11. 2. Verify that the control button is pressed in for automatic control of the lift axle. 3. Remove the yellow cap on the tube. Using the adjustment wrench (904, 053, 001), turn in the nut until it stops. DO NOT TORQUE! 4. Allow the pressure to equalize at the test port gauge to that of the regulated pressure gauge. Once equalized slowly back out (turn to the left) the Ps1 adjustment nut using the adjustment wrench (904 053 001). When the valve exhausts stop adjustment, the valve has been set. 5. Verify that valve has been set correctly by repeating steps 1-5 of the functional check. 6. Enter the current Ps1 setting on the valve or in an area visible from the lift axle(s). Replace the protective cap. Figure 1 Figure 2 Installation Instructions for the 90555288 (Fully Automatic) The operation of the lift axle is fully automatic based on the load applied to the vehicle. The lift axle can be automatically lowered after the predefined control pressure, Ps1, has been reached. Likewise, the lift axle will automatically lift when the second predefined control pressure, Ps2, has been reached. Control pressures can be set to specific vehicle loads. Functional Check for Valve 1. Connect gauge and regulator to port 11 2. Connect pressure gauge to test port (Metric M16x1.5 threaded fitting). 3. Verify current Ps1 setting by setting the regulated pressure into the 11 port to 80 psi. 4. Watch for the point on the test port gauge that the valve exhausts and triggers the lowering of the axle(s). 5. with Ps1 triggered regulated the port 11 pressure down to 10 psi. 6. Watch for the point on the test port gauge that the valve exhausts and triggers the raising of the axle(s). 7. Relieve pressure from test port. The ILAS III Automatic is factory set at 62 psi for Ps1. It is important when making an adjustment to the Ps1 setting that the adjustment is made from a higher Ps1 setting to a lower Ps1 Setting. If this is not followed then the Ps1 will be triggered before the adjustment can be made. Ps1 can be set between 44 and 76 psi. Setting the Control Pressure Ps1 1. Set the desired pressure for lowering the lift axles using the regulator in port 11. 2. Remove the yellow cap on the tube. Using the adjustment wrench (904, 053, 001), turn in the nut until it stops. DO NOT TORQUE! 3. Allow the pressure to equalize at the test port gauge to that of the regulated pressure gauge. Once equalized slowly back out (turn to the left)the Ps1 adjustment nut using the adjustment wrench (904 053 001). When the valve exhausts stop adjustment, the valve has been set. 4. Verify that valve has been set correctly by repeating steps 1-5 of the functional check. The ILAS III Automatic is factory set at 20 psi for Ps2. In order to make an adjustment to Ps2, Ps1 must be triggered first. It is important when making an adjustment to the Ps2 setting that the adjustment is made from a lower Ps2 setting to a higher Ps2 Setting. If this is not followed the Ps2 will trigger before the adjustment can be made. The Ps2 has an adjustment range of 10 to 45 psi. This is dependent on the Ps1 setting. See Figure 5 for adjustable range. Setting the Control Pressure Ps2 1. Remove red cap, with fingers back out white nut until the face of the nut is at the end of the threads. DO NOT REMOVE WHITE NUT FROM STUD! 2. Ps1 must be triggered before setting Ps2. Set regulated pressure in port 11 to 80 psi, allow test port to equalize with port 11 pressure. 3. Once equalized, regulate the pressure in port 11 down to the desired Ps2 setting. Allow the test port gauge to equalize. 4. Turn in white nut (turn to the right) until valve activates. The Ps2 has now been set. 5. Verify that valve has been set correctly by repeating steps 1-7 of the functional check above. slight adjustment may be needed to precisely set Ps1 and Ps2 as an adjustment to one can affect the adjustment of the other. 6. Replace protective caps. Enter the current Ps2 and 2 settings on the valve or in an area visible from the lift axle(s).

Installation Instructions for the 90555288 (Fully Automatic) cont d Fully Automatic ILAS III Manual Override Installation Instructions The following steps are taken to fit the ILAS III Automatic Valve with a manual override system. Refer to Figure 6 during component installation. 1. Remove rubber cap on test connection port. (Refer to Figure 3) 2. Remove test port fitting and ILAS III Valve plug. The test fitting and plug will be removed as one piece. 3. Carefully remove the test fitting from the plug. WARNING: Do not damage the plug threads or the o-ring. If the threads or the o-ring are damaged, the valve will not seal correctly and the valve may no longer function properly. Figure 3 4. Thread in and tighten push to connect fitting.do not use Teflon tape as a thread sealant 5. Insert the plug and fitting assembly into the ILAS III Valve in the original location. (Refer to Figure 6) 6. Tighten the valve plug and PTC fitting assembly into ILAS III Valve. 7. Determine the mounting location of the ball valve. The ball valve will be used to manually lift and lower the axle when unloaded. The ball valve should be in a location that is easy to see as well as protected from unintentional activation. 8. Install fittings into the ball valve. One ¼ fitting as well as one 3/8 fitting are needed. 9. Place ball valve in desired location in the OFF position. 10. Connect ¼ line to the newly installed PTC fitting and ¼ fitting on the ball valve. Connect 3/8 line to the opposite end of the ball valve and the supply line. See plumbing diagram for reference. 11. Check system for leaks. NOTE: If leaks are present the system may not function properly in the automatic mode. 12. Check system for proper function. Ball valve ON = Lift axle will drop when trailer is unloaded Ball valve OFF = Lift axle will retract when trailer is unloaded Figure 4 NOTE: The valve will resume fully automatic operation when the ball valve is in the OFF position. NOTE: When the manual override is used, the system may take several minutes to lift or lower the axles. The system is operating properly and this is not a cause for alarm. The ball valve should remain OPEN or CLOSED until the axles are in the full up or down position. Refer to the above sections to adjust the operating pressures of the Automatic ILAS III Valve. Figure 5 Figure 6

Manual ILAS III Valve Automatic ILAS III Valve with Manual Override Commercial Vehicle Systems Haldex Brake Products Corporation 10930 N. Pomona Ave. Kansas City, MO 64153-1256 Phone: 816-891-2470 Fax: 816-891-9447 Haldex Limited/Haldex Limitée 500 Pinebush Road, Unit 1 Cambridge, Ontario Canada N1T 0A5 Phone: 519-621-6722 Fax: 519-621-3924 www.haldex.com Automatic ILAS III Valve L31227 US 3/10 ART ONLY

Información general La válvula ILAS III se utiliza para bajar o subir uno o varios ejes dependiendo en la suspensión del paseo del aire de la carga aplicada al vehículo. Guia para Instalar L31227 (94130007) Rev 6/10 Ensamble Utilice los agujeros que se proporcionan para instalar la válvula ILAS III. Asegúrese de que la válvula esté colocada en una ubicación protegida del agua de la carretera y de la limpieza a presión alta. Las guarniciones en la válvula deben señalar hacia abajo. Consulte la Figura 1 y la Figura 3. Nota: Si utiliza lavado a presión alta para limpiar el vehículo, debe guardar una distancia de por lo menos 50 cm (20"). El botón de control (versión manual) debe ser accesible fácilmente y no debe sobresalir del borde del vehículo cuando lo saca. También debe proteger la válvula para que no se active por accidente. Si va a pintar o a aplicar recubrimiento a la válvula evite pintar agote el agujero de respiradero y el cargador de goma para el botón del control (versión manual). Revise y registre la presión de disminución de la válvula o en un área visible del eje de elevación. Descripción del puerto: 1 = Suministro 11 = Bolsas de suspensión de aire 21,22 = Bolsas de aire de suspensión de eje de elevación 23 = Bolsas de elevación 3 = Escape Advertencia: Mantenga despejada el área del eje de elevación. El eje bajará de manera automática cuando alcance la presión de disminución. 90555293 90555288 Instrucciones de instalación de la válvula ILAS III 90555288 90555293 Número Completamente Elevación de parte automático manual Eje inferior Eje de elevación Funcionamiento manual Tamaño de ajuste del puerto Automáticamente se basa en la configuración Ps1 y en la carga del vehículo Automáticamente se basa en la configuración Ps2 y en la carga del vehículo Con el uso de componentes de anulación manual 3/8" PTC Automáticamente se basa en la configuración Ps2 y en la carga del vehículo Manualmente con el uso del botón de control Con el uso del botón de control 3/8" PTC

Instrucciones de instalación de 90555293 (elevación manual) Los ejes de elevación bajan automáticamente cuando el vehículo está cargado. El botón de control se utiliza entonces para levantar el eje de elevación cuando el vehículo no está cargado. Cuando el vehículo esté descargado, el botón de control se puede jalar para bajar manualmente los ejes. NOTA: Para determinar la presión de Ps1 deseada conecte el manómetro en la línea de resorte de aire y cargue el vehículo según lo desee para bajar el eje. La presión de Ps1 se puede ajustar a la presión deseada. Revisión funcional de la válvula 1. Conecte el calibrador y el regulador al puerto 11 2. Conecte el manómetro al puerto de prueba (Conector roscado métrico M16x1.5). 3. Verifique la configuración actual de Ps1 al establecer la presión regulada en el puerto 11 a 80 psi. 4. Observe el punto en el calibrador de puerto de prueba donde la válvula sale y activa la bajada de los ejes. 5. Alivie la presión del puerto de prueba. El manual de ILAS III es fábrica fijada en 62 PSI para Ps1. Es importante cuando ajusta la configuración de Ps1 que se realice el ajuste de una configuración de Ps1 más alta a una configuración de Ps1 más baja. Si no lo hace de esta manera, entonces el Ps1 se activará antes de que se pueda realizar el ajuste. El Ps1 se puede fijar entre 44 y 76 PSI. Configuración de Ps1 de presión de control 1. Establezca la presión deseada para bajar los ejes de elevación con el regulador en el puerto 11. 2. Verifique que el botón de control se presione para el control automático del eje de elevación. 3. Retire la tapa amarilla en el tubo. Usando la llave del ajuste (904, 053, 001), dé vuelta en la tuerca hasta que pare. NO APRIETE! 4. Deje que la presión se nivele en el calibrador de puerto de prueba al manómetro regulado. Una vez nivelado regrese lentamente (gire a la izquierda) la tuerca de ajuste de Ps1 con la llave de ajuste (904 053 001). Cuando el escape de la válvula detiene el ajuste, la válvula se estableció. 5. Verifique que la válvula se haya establecido correctamente al repetir los pasos del 1 al 5 del cheque funcional. 6. Ingrese la configuración actual de Ps1 en la válvula o en el área visible de los ejes de elevación. Substituya la tapa protectora. Puerto de prueba Agujeros de montaje Escape Puerto 11 Bolsas de aire de suspensión Botón de control Instrucciones de instalación de 90555293 (elevación manual) El funcionamiento del eje de elevación es completamente automático con base en la carga aplicada al vehículo. El eje de elevación puede bajar de manera automática después de alcanzar la presión de control predeterminada, Ps1. Así mismo, el eje de elevación se elevará de manera automática cuando alcance la segunda presión de control predeterminada, Ps2. Las presiones de control se pueden establecer en cargas de vehículo específicas. Revisión funcional de la válvula 1. Conecte el calibrador y el regulador al puerto 11 2. Conecte el manómetro al puerto de prueba (Conector roscado métrico M16x1.5). 3. Verifique la configuración actual de Ps1 al establecer la presión regulada en el puerto 11 a 80 psi. 4. Observe el punto en el calibrador de puerto de prueba donde la válvula sale y activa la bajada de los ejes. 5. con Ps1 activado y el puerto 11 regulado baje la presión a 10 psi. 6. Observe el punto en el calibrador de puerto de prueba donde la válvula sale y activa la elevación de los ejes. 7. Alivie la presión del puerto de prueba. Configuración de Ps1 de presión de control 1. Establezca la presión deseada para bajar los ejes de elevación con el regulador en el puerto 11. 2. Retire la tapa amarilla en el tubo. Usando la llave del ajuste (904, 053, 001), dé vuelta en la tuerca hasta que pare. NO APRIETE! 3. Deje que la presión se nivele en el calibrador de puerto de prueba al manómetro regulado. Una vez nivelado regrese lentamente (gire a la izquierda) la tuerca de ajuste de Ps1 con la llave de ajuste (904 053 001). Cuando el escape de la válvula detiene el ajuste, la válvula se estableció. 4. Verifique que la válvula se haya establecido correctamente al repetir los pasos del 1 al 5 del cheque funcional. El ILAS III automático es una configuración de fábrica a 20 psi para Ps2. Para realizar un ajuste a Ps2, debe activarse primero el Ps1. Es importante cuando ajuste la configuración de Ps2 que el ajuste se realice de una configuración de Ps2 más baja a una configuración de Ps2 más alta. Si no lo hace de esta manera, entonces el Ps2 se activará antes de que se pueda realizar el ajuste. El Ps2 tiene un rango de ajuste de 10 a 45 psi. Esto depende de la configuración de Ps1. Consulte la Figura 5 para conocer el rango ajustable. Configuración de Ps2 de presión de control 1. Retire la tapa roja, con los dedos retire la tuerca blanca hasta que la superficie de la tuerca esté en el extremo de las roscas. NO RETIRE LA TUERCA BLANCA DEL ESPÁRRAGO! 2. Debe estar activado Ps1 antes de configurar Ps2. Establezca la presión regulada en el puerto 11 a 80 psi, deje que el puerto de prueba se nivele con la presión del puerto 11. 3. Una vez nivelado, regule la presión en el puerto 11 hacia abajo a la configuración deseada de Ps2. Deje que se nivele el calibrador de puerto de prueba. 4. Gire la tuerca blanca (gírela a la derecha) hasta que se active la válvula. El Ps2 ahora está establecido. 5. Verifique que se haya establecido correctamente la válvula al repetir los pasos del 1 al 7 de la verificación funcional que se menciona anteriormente. Es posible que sea necesario realizar un ligero Ajustes Ps1 y Ps2 ya que el ajuste a uno puede afectar el ajuste del otro. 6. Reemplace la tapas protectora. Ingrese la configuración actual de Ps2 en la válvula o en el área visible de los ejes de elevación. Ubicación de ajuste de presión de disminución Ps1 Figura 1 Figura 2

Instrucciones de instalación de 90555288 (completamente automático) continuación Instrucciones de instalación de anulación manual de ILAS III completamente automática Agujeros de montaje Ubicación de ajuste de presión de elevación Ps2 Escape Los siguientes pasos se utilizan para ajustar la válvula ILAS III automático con un sistema de anulación manual. Consulte la Figura 6 durante la instalación del componente. 1. Retire el tapón de caucho del puerto de conexión de prueba. (Consulte la Figura 3) 2. Retire el conector del Puerto de prueba y el tapón de la válvula ILAS III. El conector de prueba y el tapón se retiran como una sola pieza. 3. Retire cuidadosamente el conector de prueba del tapón. ADVERTENCIA: No dañe las roscas del tapón o el empaque de anillo. Si daña las roscas o el empaque de anillo, la válvula no sellará correctamente y es posible que ya no funcione bien. Puerto de prueba Ubicación de ajuste de presión de disminución Ps1 Figura 3 Puerto 11 Bolsas de aire de suspensión 4. Rosque adentro y apriete el empuje para conectar la guarnición. No utilice cinta de teflón como sellador de roscas. 5. Inserte el ensamble del tapón y conector en la válvula ILAS III en la ubicación correcta. (Consulte la Figura 6) 6. Apriete el ensamble del tapón de la válvula y del conector de PTC en la válvula ILAS III. 7. Determine la localización del montaje de la vávula de bola. La vávula de bola será utilizada para levantar y para bajar manualmente el árbol cuando está descargada. La vávula de bola debe estar en una localización que sea fácil de considerar tan bien como protegido contra la activación inintencional. 8. Instale los conectores en la válvula de bolas. Necesita un conector de ¼" y un conector de 3/8". 9. Coloque la válvula de bolas en la ubicación deseada en la posición APAGADO. 10. Conecte la línea de ¼" en el conector PTC recién instalado y el conector de 1/4" en la válvula de bolas. Conecte la línea de 3/8" en el extremo opuesto de la válvula de bolas y la línea de suministros. Consulte el diagrama de instalación de tubos como referencia. 11. Revise si el sistema tiene fugas. NOTA: Si encuentra fugas es posible que el sistema no funcione correctamente en modo automático. 12. Revise si el sistema funciona correctamente. Figura 4 Válvula de bolas Encendida = el eje de elevación bajará cuando el remolque esté descargado. Válvula de bolas Apagada = el eje de elevación se retraerá cuando el remolque esté descargado. Válvula ILAS Ps2 (psi) Área ajustable Ps1 (psi) Figura 5 Nota: La válvula reanudará afuncionamiento completamente automático cuando la válvula de bolas esté en posición Apagada. Conector de anulación manual Empaque de anillo Tapón de la válvula ILAS Nota: Cuando utiliza la anulación Figura 6 manual el sistema puede tardar algunos minutos para elevar o bajar los ejes. El sistema funciona correctamente y no es motivo de alarma. La válvula de bolas debe permanecer Encendida o Apagada hasta que los ejes estén en la posición completamente hacia arriba o hacia abajo. Consulte las secciones anteriores para ajustar las presiones de funcionamiento de la válvula ILAS III automática.

Válvula ILAS III Manual Válvula ILAS III Automática con anulación manual Commercial Vehicle Systems Haldex Brake Products Corporation 10930 N. Pomona Ave. Kansas City, MO 64153-1256 Phone: 816-891-2470 Fax: 816-891-9447 Haldex Limited/Haldex Limitée 500 Pinebush Road, Unit 1 Cambridge, Ontario Canada N1T 0A5 Phone: 519-621-6722 Fax: 519-621-3924 www.haldex.com Válvula ILAS III Automática L31227 US Rev 6/10 ART ONLY