ULP (Universal Logic Plug) System User Guide. Sistema de conexión ULP (Conector Lógico Universal) Guía de usuario



Documentos relacionados
DECLARACION DE CONFORMIDAD DECLARATION OF CONFORMITY

Installation Guide. Green momit

ENA. POWERLOGIC Enercept Network Adapter Adaptador de red Enercept (instructionnes en español: página 5) ENGLISH INTRODUCTION INSTALLING THE ENA

Agustiniano Ciudad Salitre School Computer Science Support Guide Second grade First term

Instruction Bulletin. Power Supply. for use with POWERLINK G3 systems para utilizarse en los sistemas POWERLINK G3 (instructionnes en español: page 9)

Video Server. Quick Installation Guide. English, Español

With temperature switch Cover for protection against high surface temperatures

OSCILLATION 512 (LM 3R)

ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

ABB SACE Communication Capability Portfolio Low voltage Breakers

IE12_ CONSOLIDACIÓN Y DESARROLLO DE NUEVAS TÉCNICAS DE EVALUACIÓN INTENSIVAS ON-LINE YA IMPLEMENTADAS POR EL GIE E4

Modbus RTU - RS-485 Kit. Kit Modbus RTU / RS-485. Kit Modbus RTU / RS-485. SSW-07 / SSW-08 English / Español / Português Document: 0899.

KMR SCA-05 Mounting Instructions Instrucción de Montaje Instruções de Montagem

Hard Disk Drive Duplicator Dock USB 3.0 to SATA HDD Duplicator. StarTech ID: SATDOCK22RU3

SEÑALIZADORES SQ A A A B CONFIGURACIÓN Y DESCRIPCIÓN

Save Money 2-up Single Doorhanger Set OH payday advance edition, 4 different doorhangers, Spanish

EP-2906 Manual de instalación

ASTROLUM TCS ASTROLUM TCS. ASTROLUM TCS es un sistema de telegestión para instalaciones de alumbrado público.

Cables monopolares media tensión aislados 90 ºC Monopolar insulated medium voltage cables 90 ºC

PRODUCT DATASHEET. Low insertion terminals. Basic self-locking under TP design Receptacles for 6.3*0.8 Tabs.

SISTEMAS DE PROTECCIÓN ELÉCTRICA

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module

Sistema de Luminarias Tecnológica - Verde - Eficiente

Quick Installation Guide TU2-DVIV H/W: V1.0R

DUAL SDL P&P REF: HI / /15

LAB 2: Circuitos de Corriente Directa (DC) PARTE I OBJECTIVES

ARTICULO: Indicador entrada programable Multi input indicator

IDC50. IDC50 Female. IDC50 Male

LED Strobe Panel - Manual

UPV software for risk models

NAVIGATOR NODE POE. Art-Net to DMX node USER MANUAL / MANUAL DE USUARIO

manual de servicio nissan murano z51

Extension Cords Extensiones Eléctricas We light your world

Contents. Introduction. Aims. Software architecture. Tools. Example

Ejercicios Input/Output 11 de Mayo, 2013

Guía de instalación rápida TEG-160WS TEG-240WS

AUTOMATISMOS PRÁCTICAS DE PROGRAMACIÓN S7300 EN LENGUAJE DE CONTACTOS KOP

DISEÑO DE UN CRONOTERMOSTATO PARA CALEFACCIÓN SOBRE TELÉFONOS MÓVILES. Entidad Colaboradora: ICAI Universidad Pontificia Comillas.

Table of Contents. Español Antes de iniciar Cómo conectar Cómo utilizar el conmutador... Troubleshooting... Version

INSTALLATION GUIDE. AXIS T92A10 Protective Housing ENGLISH ESPAÑOL

Los números. 0 cero 1 uno / un 2 dos 3 tres 4 cuatro. 6 seis 7 siete 8 ocho 9 nueve 10 diez 5 cinco

Quick Installation Guide Internet Setup

PHOENIX OVIPOSITOR. Introducción...2 Capacidades / Posibilidades / Ventajas...3 Expansiones / Características técnicas...4

Modbus RTU - RS-232 Kit. Kit Modbus RTU / RS-232. Kit Modbus RTU / RS-232. Installation Guide. Guia de Instalación. Guia de Instalação

Sistemas de impresión y tamaños mínimos Printing Systems and minimum sizes

Consumo de combustible de motor diésel, generadores, calderas y calentadores.

CESVA USB DRIVER. M_CUD_v0001_ _ESP_ENG

FIRE RED FUZZ. Bill Of Materials

ARTICULO: L Actuador Eléctrico Reversible GE Multivoltage GE Multivoltage Reversible Electric Actuator

Matemáticas Muestra Cuadernillo de Examen

USER MANUAL MANUAL DEL USUARIO HBP500-SM HBP700-SM HBP900-SM HBP1100-SM SENTEY

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual DECLUTCHABLE WORM GEAR

LV Surge Protection Devices Módulos De Protección Contra Sobretensiones De Bajo Voltage

Sistema de retención para mangueras de presión

8 Port VGA over Cat5 Digital Signage Broadcaster with RS232 & Audio

Sensor de Proximidad Inductivo IKZ GH

CONTROLADORA PARA PIXELS CONPIX

Barclaycard Center Identidad Visual / Visual Identity Uso de la marca como referencia / Use of the brand as reference

Creating your Single Sign-On Account for the PowerSchool Parent Portal

INSTALLATION INSTRUCTIONS

M DJ SERIES. User Manual/Manual de Uso

Manual de Instrucciones

Sierra Security System

In the following you see an example of a SPAC calculation run. BKtel systems Seite 1/8

Quick Installation Guide Internet Setup

SCADA BASADO EN LABVIEW PARA EL LABORATORIO DE CONTROL DE ICAI

SISTEMA DE CONTROL LÓGICO PROGRAMABLE (PLC) SOBRE HARDWARE EMBEBIDO Y BAJO SISTEMA OPERATIVO LINUX

SIHI México, S. de R.L. de C.V. Pricing Guide

NEXUS 3001XLM-IMP Brinell hardness tester

INGESAS CG6. FO Modem Data Sheet


AUTOMATIC TRANSFER SWITCH

Incremental Rotary Encoders

GUÍA DE USUARIO PC Bienvenidos al mundo Perfect Choice. Antes de comenzar a usar el producto es importante que leas esta guía.

Guía de conectividad de máquinas Jofemar Jofemar machines Connectivity guide

Nueva confirmación de pedido de compra con cambios: proveedor ES

Adaptado Por: Alexander Chaverra Instructivo Configuración PPjoy Y SmartPropo Para Aerofly

2008 Series Hemodialysis Machine Operator s Manuals Addendum for Concentrate Connection

Guía de Instalación Oracle Business Intelligence Enterprise Edition ( ) Advanced Installation Type

Filtros footprint para convertidores Footprint filters for LSIS inverters

FCC Information : Warning: RF warning statement:

Portable esata USB to SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: SATDUPUEGB

REOVIB MFS 268 IP 54 or IP 20, Frequency-control with automatic detection of the resonant frequency

Miniature Circuit Breakers Type GMB63

ARMARIOS PARA INSTALACIONES INTEGRADAS ENCLOSURES FOR INTEGRATED INSTALATIONS

app ADSL2V1 COMMUNICATIONS LINE

T R A N S TECHNICAL SPECIFICATIONS:

INSTRUCCIONES PARA ENVIAR SU PELICULA PARA LA VIDEOLIBRERIA

SUSTITUCIÓN DE TUBOS FLUORESCENTES POR TUBOS DE LEDs CHANGING FLUORESCENT TO LED TUBES

Specifications, Installation, and Operating Instructions GrowerSELECT 230 VAC Replacement Feed Sensor With Heating Element HS09

MANUAL BREVE DE INSTRUCCIONES PARA INSTALAR EL BLOQUE DE VIDEOCONFERENCIA EN MOODLE

Circuitos Básicos con OAs

Final Project (academic investigation)

MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL

Light Package Switches Interruptores ligeros del Paquete

Light Package Switches Interruptores ligeros del Paquete

Process Control Work Instructions Control de Procesos Instrucciones de Trabajo. for / para

PLACA CALLE SLIM REF. PDA201 REF. PDV701

Connecting Cloudino Connector to FIWARE IoT

Transcripción:

ULP (Universal Logic Plug) System User Guide Sistema de conexión ULP (Conector Lógico Universal) Guía de usuario Système de fiche logique universelle (ULP) Guide de l utilisateur Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48940-39-0 Rev. 0, 0/03 Retain for Future Use. / Conservar para uso futuro. / À conserver pour usage ultérieur.

ULP (Universal Logic Plug) Connection System User Guide ENGLISH Instruction Bulletin 48940-39-0 Rev. 0, 0/03 Retain for future use.

ENGLISH

ULP (Universal Logic Plug) System 48940-39-0 Table of Contents Rev. 0, 0/03 SECTION : ULP SYSTEM...7 ENGLISH Description of ULP System...7 Intelligent Modular Unit (IMU)... 8 ULP System Modules and Accessories... 0 ULP Modules... 0 RJ45 Connector... 0 Updating the Firmware in ULP Modules... ULP Connections... Isolated Repeater... Connecting the Circuit Breaker to the ULP System... Micrologic 5 and 6 Trip Units... Breaker Status Control Module (BSCM)... NSX Cord... Connection to the ULP System... 3 Applications... 4 Metering and Display Functions... 4 Modbus Communication Function... 6 Metering, Display, and Modbus Communication Functions... 8 SECTION : ULP SYSTEM ARCHITECTURE...0 ULP Connection and Power Supply Rules... 0 General Rules... 0 Length of ULP Cables... 4 Vdc Power Supply... Summary of Connection Rules... ULP System Power Supply...3 ULP Module Consumption... 3 Power Supply Rating... 3 Examples of 4 Vdc Power Supplies... 3 Segmented Power Supply... 4 Connection of the 0 V... 4 Rules for Connection to the Modbus Network...5 Connection of Intelligent Modular Units (IMUs)... 5 Composition of the Modbus Cable... 5 Connection to the Modbus Interface Module... 6 Modbus Line Termination... 6 General Rules for Modbus Cable Length... 7 Connection to the Modbus Master... 7 Modbus Network Contained in Switchboard... 7 Modbus Network Not Contained in Switchboard... 7 Ethernet Connection Linking Two Switchboards... 8 Modbus Connection Linking Two Switchboards... 9 ULP System Architectures... 30 ULP System Connections... 30 Choice of Architecture... 30 Standalone Architecture... 3 Centralized Modbus Architecture... 3 Modbus Cable Connection...33 Ethernet Gateway Power Supply... 34 Case of a Single Power Supply Segment... 35 Modbus Cable Connection with a Single Power Supply Segment... 36 Modbus Cable Lengths for a Single Power Supply Segment... 37 Case of Several Power Supply Segments...38 Connection of Modbus Cable with Several Power Segments... 39 Modbus Cable Lengths for Several Power Supply Segments... 40 Daisy-Chained Distributed Modbus Architecture...4 Derivation Terminal Block on the Switchboard Incomer... 4 Modbus Cable Connection...43 3-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Table of Contents Modbus Cable Lengths for a Single Power Supply Segment... 44 Case of Several Power Supply Segments... 45 Derivation Terminal Block on the Incomer of the Third Cubicle... 45 Modbus Cable Connection... 46 Modbus Cable Lengths for Several Power Supply Segments... 47 Derivated Distributed Modbus Architecture... 47 Derivation Terminal Block on the Switchboard Incomer... 49 Modbus Cable Connection... 50 Derivation Terminal Block on the Cubicle Incomer... 5 Modbus Cable Lengths for a Single Power Supply Segment... 5 Case of Several Power Supply Segments... 53 Derivation Terminal Block on the Incomer of the Second Cubicle... 54 Modbus Cable Connection... 55 Derivation Terminal Block on the Incomer of the Third Cubicle... 56 Modbus Cable Connection... 56 Modbus Cable Lengths for Several Power Supply Segments... 58 Pluggable Terminal Block... 59 ENGLISH SECTION 3: MODBUS INTERFACE MODULE... 60 Function... 60 Characteristics... 60 Part Numbers... 60 Installing the Modbus Interface Module... 60 Mounting... 60 Direct Mounting on DIN Rail... 6 Mounting on the Stacking Accessory... 6 ULP Connection... 6 5-Pin Connector (Modbus and 4 Vdc Power Supply)... 6 Operation of the Modbus Interface Module... 6 Modbus Address... 6 Modbus Traffic LED... 63 Modbus Locking Pad... 63 Test LED... 63 Test Button... 64 Mechanical Lock... 64 Configuration... 64 Automatic Configuration... 64 Custom Configuration... 65 SECTION 4: FRONT DISPLAY MODULE (FDM)... 66 Function... 66 Characteristics... 66 Part Numbers... 66 Installing the FDM... 67 Mounting... 67 Door Cut-Out Mounting... 67 Door Cut-Out Mounting for Standalone Architecture... 67 Door Cut-Out Mounting for Communicating Architecture... 68 Hole Mounting... 68 Hole Mounting for Standalone Architecture... 69 Hole Mounting and ULP Terminations... 69 Hole Mounting for Communicating Architecture... 70 ULP Connection... 70 4 Vdc Power Supply... 7 Functional Ground... 7 Operation of the FDM... 7 Navigation Keys... 73 Alarm Indicator LED... 73 0 03 Schneider Electric All Rights Reserved 4-EN

ULP (Universal Logic Plug) System 48940-39-0 Table of Contents Rev. 0, 0/03 ENGLISH Example of an Alarm Pop-Up... 74 Main Menu... 75 Choice of Language... 76 Setting the Contrast...77 Setting the Brightness... 78 Product Version... 79 Intelligent Modular Unit (IMU) Name... 80 Settings Retained in the Event of a Power Failure... 80 SECTION 5: UTA TESTER...8 Function... 8 Connection to the Intelligent Modular Unit (IMU)... 8 Operating Modes... 8 UTA Tester Kit... 8 Bluetooth Connection... 8 Connection Type... 83 Characteristics... 83 Part Numbers... 84 Mounting...84 Connection to the Test Port on the Micrologic Trip Unit... 85 Connection in Standalone Mode... 85 Connection to a computer... 85 USB Connection... 85 Bluetooth Connection... 86 UTA Tester ULP Connection... 86 Example of ULP Connection... 86 ULP Connection Procedure... 87 Using the UTA Tester Connected to the Test Port on the Micrologic Trip Unit... 88 Standalone Mode... 88 ON LED... 88 Test Functions... 88 Connection to a computer... 89 USB Connection... 89 Bluetooth Connection... 89 Using the UTA Tester Connected to the ULP System... 90 ON LED... 90 ULP LED... 90 External Power Supply LED... 9 USB Connection... 9 Bluetooth Connection... 9 Use Summary... 9 SECTION 6: REMOTE SETTING UTILITY (RSU) SOFTWARE... 94 Function... 94 Selection...94 RSU in Offline Mode... 95 RSU in Online Mode... 95 Security... 96 RSU and the Intelligent Modular Unit (IMU)... 97 IMU Name and Location... 97 Setting the Time on the ULP Modules...98 APPENDIX A: ULP SYSTEM FOR POWERPACT H-, J- AND L-FRAME CIRCUIT BREAKERS... 99 Summary of Connection Rules... 99 ULP Cable Characteristics... 99 Modbus Cable Characteristics...99 5-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Table of Contents Connection Rules... 99 Modbus Cable Lengths... 00 Isolated Modbus Repeater Module... 0 Isolated Modbus Repeater Module Characteristics... 0 Connection Rules... 0 ULP System Part Numbers... 03 ENGLISH 0 03 Schneider Electric All Rights Reserved 6-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 Section ULP System ENGLISH Description of ULP System Use the ULP (Universal Logic Plug) system to construct an electrical distribution solution which integrates metering, communication, and operating assistance functions for PowerPact H-, J-, and L-frame circuit breakers. Figure : ULP Electrical Distribution Solution. Micrologic 5 or 6 trip unit. Front Display Module (FDM) 3. Modbus interface module 4. ULP cable 5. NSX cord 6. Modbus network 7. 4 Vdc auxiliary power supply 8. Communication gateway (EGX300) 9. Ethernet network 7-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Use the ULP system to enhance the PowerPact H-, J-, or L-frame circuit breaker functions by: Local display of measurements and operating assistance data with the front display module (FDM) A Modbus communication link for access and remote monitoring with the Modbus interface module Test, setup, and maintenance functions with the UTA tester and the Local Test Utility (LTU) and Remote Setting Utility (RSU) software The ULP system allows the PowerPact H-, J-, and L-frame circuit breakers to become metering and supervision tools to assist energy efficiency, to: Optimize energy consumption by zone or application, according to the load peaks or priority zones Better manage the electrical equipment ENGLISH Intelligent Modular Unit (IMU) An intelligent modular unit (IMU) is a mechanical and electrical assembly containing one or more products to perform a function in a switchboard (incoming protection, motor command, or control). The modular units install easily in the switchboard. The modular unit can be enhanced with the addition of the front display module. This module can display the measurement and operating data supplied by the Micrologic 5 or 6 trip units or a Modbus interface module for a link to a Modbus network. In the ULP system, the modular unit becomes intelligent when it includes metering functions and/or communication functions Table : ULP System Using Modular Units Choice Trip Unit Working With No Intelligence Thermal-Magnetic Stand Alone Unit Local Intelligence Advanced Stand Alone Unit Local Intelligence Plus Advanced With FDM Networked Intelligence Advanced Modbus Interface Local and Networked Intelligence Advanced With FDM and Modbus Interface 0 03 Schneider Electric All Rights Reserved 8-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 Figure : ULP System with Intelligent Modular Units ENGLISH Modular unit Intelligent modular unit (measurements and local display) Intelligent modular unit (measurements, local display, and communication) 9-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System ULP System Modules and Accessories ULP Modules Table : ULP Modules ENGLISH ULP Module Description Part Number Modbus interface module (IFM) 06469 The Modbus interface module allows intelligent modular units (IMUs) in the ULP system to communicate using the Modbus protocol. The Modbus interface module is described in Modbus Interface Module on page 60. STRV000 Front Display Module (FDM) 06486 The FDM is a local display unit displaying measurements and operating assistance data from the IMU. The FDM is described in Front Display Module (FDM) on page 66 STRV00 UTA tester 06486 Use the UTA tester to test, set-up, and maintain the IMU modules, using the RSU and LTU software. The UTA tester is described in UTA Tester on page 8. STRV009 RSU software LV4ST00 LTU software LV4ST RJ45 Connector ULP modules have RJ45 connectors, identified by the pictogram. Generally, each ULP module has two identical RJ45 connectors in parallel to connect the IMU ULP modules in a daisy chain, in any order, using ULP cables. Figure 3: RJ45 Connectors 06486 0 03 Schneider Electric All Rights Reserved 0-EN

> 3 0 A > 3 0 A 3 0 3 0 % % Ir > > Ir.9.9.9.9 3 3.5.9.9.9.5.9 4.5 4.5 3 3.9 5.9 5.9 6 Ir (x Io ) 4.9.9.9 8 0 5 I s d(x Ir) Ir (x Io ) 4 6.9.9 8 0 5 I s d(x Ir) 8 8 6 6 ic r lo ic g r lo i g i 5. 5. 7 7 ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 ENGLISH Updating the Firmware in ULP Modules The user can update the ULP module (IFM, FDM, UTA Tester) firmware using the RSU software. Download the update files from the Schneider Electric website at: www.schneider-electric.com. For more information, refer to Section 6- Remote Setting Utility (RSU) Software on page 94. The operating compatibility matrix of firmware versions can also be downloaded. Use the compatibility matrix to check that the ULP system functions correctly depending on the firmware version in each IMU module. ULP Connections ULP modules interconnect using simple plug-and-play ULP cables, without prior set-up. Table 3: ULP Connections ULP Module Interconnection Connection Description 06488 ULP Cable 06487 ULP Line Termination 06489 Use ULP cables to interconnect ULP modules within a single IMU. They have male RJ45 connectors at both ends and are available in several lengths. The ULP line termination closes the unused ULP connector on a ULP module. It consists of an RJ45 connector and passive components in a sealed unit. L = 0.98 ft. (0.3 m) (0 cables) L =.98 ft. (0.6 m) (0 cables) L = 3.8 ft. ( m) (5 cables) L = 6.56 ft. ( m) (5 cables) L =9.84 ft. (3 m) (5 cables) L = 6.4 ft. (5 m) ( cable) 0 ULP line termination Part Number TRV00803 TRV00806 TRV0080 TRV0080 TRV00830 TRV00850 TRV00880 > 0 > 0 M Mo o c c E E. NSX cord. ULP cables RJ45 Female/Female Connector 06490 Use the RJ45 female/female connector to connect two ULP cables end-to-end and thus extend them. It consists of two female RJ45 connectors linked by a direct electrical connection. For an example of use of the RJ45 female/female connector, see Hole Mounting on page 68. 0 RJ45 female/female connectors TRV00870 Isolated Repeater Use a two-wire RS485 Isolated Repeater to insulate between voltage differences. Install only one insulated repeater in any switchboard or panelboard. The Insulated Repeater is required when: there is not another interface (such as an EGX) at the switchboard level in the installation when the Modbus RS485 network is wired across the site. The Insulated Repeater creates an interface between RS485 network disturbances and the switchboard, protecting against voltage differences between remote grounds. The Insulated Repeater acts as a switchboard access point. -EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Connecting the Circuit Breaker to the ULP System Micrologic 5 and 6 Trip Units Use the NSX cord to connect the PowerPact H-, J-, and L-frame circuit breakers to the ULP system. The circuit breaker must have a BSCM or a Micrologic 5 or 6 trip unit. Micrologic 5 and 6 trip units provide multiple functions. Protecting the electrical distribution system or specific applications Metering instantaneous and demand values for electrical quantities Kilowatt hour metering Operating information (such as peak demand, customized alarms, and operation counter) Communication For more information about the Micrologic 5 and 6 trip units, refer to the Micrologic 5 and 6 Electronic Trip Units User Guide. ENGLISH Breaker Status Control Module (BSCM) Table 4: BSCM 0649 Description The BSCM (Breaker Status Control Module): Provides status indication functions for PowerPact H-, J-, and L-frame circuit breakers Controls of the communicating electrical motor operator Provides operating assistance functions Use the BSCM with standard and advanced Micrologic electronic trip units. For more information, refer to the circuit breaker instructions shipped with the circuit breaker. Part Number S43405 NSX Cord NSX Cords are internal connection blocks used to connect a PowerPact H-, J-, or L-frame circuit breaker equipped with the BSCM and/or the Micrologic 5 or 6 trip unit to a ULP module with its RJ45 connector. Table 5: NSX Cord Description Length Part Number 0649 NSX Cord Cable with male RJ45 connector for direct connection to a ULP module. L = 4.3 ft. (.3 m) L = 9.8 ft. (3 m) S4340 S4340 06465 NSX Cord V > 480 Vac Cable with female RJ45 connector. Use a ULP cable to connect the NSX Cord > 480 Vac and its Insulation Module to a ULP module. L = 4.3 ft. (.3 m) L = 9.8 ft. (3 m) S43404 S434303 For more information about the NSX cord, refer to the circuit breaker instructions shipped with the circuit breaker. 0 03 Schneider Electric All Rights Reserved -EN

> 3 0 A 3 0 % > Ir 0 0 5 0 4 0 6 0 I o (A ) 5 7 0 5 0 5 0.9.9 3.9.9 4.9 5.9 6.9.9 8 7.5.5 3 4 s d(x Ir 5 0 8 6 Ir Is d ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 ENGLISH Connection to the ULP System Figure 4: Connection to ULP System Connect the PowerPact H-, J-, or L-frame circuit breaker to the IMU with the NSX cord. A. NSX cord B. BSCM C. Micrologic or 3 trip unit D. Micrologic 5 or 6 trip unit A 06496 A A B B B C > 0 Ir (x Io ) I ) 3. Micrologic C D L-frame circuit breaker with NSX cord and standard Micrologic trip unit H-frame circuit breaker with NSX cord, BSCM, and standard Micrologic trip unit H-frame circuit breaker with NSX cord, BSCM, and Micrologic 5 or 6 trip unit 3-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Applications Increase functionality of a switchboard containing PowerPact H-, J-, or L- frame circuit breaker modular units with the addition of metering, display, and Modbus communication functions. Metering and Display Functions To incorporate metering functions, the PowerPact H-, J-, or L-frame circuit breaker must have a Micrologic 5 or 6 trip unit. The Micrologic trip unit provides the metering values on its local display, on the FDM, or through supervisory software using the communcation system. ENGLISH Figure 5: Panelboard with Metering Functions 06499 The Micrologic 5 or 6 trip unit gives the IMUs all the Power Meter data as well as assistance with operation of the PowerPact H-, J- or L-frame circuit breaker (alarms associated with measurements, history, and tables of timestamped events, maintenance indicators). 0 03 Schneider Electric All Rights Reserved 4-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 Figure 6: Wiring Diagram for Panelboard with Metering Functions ENGLISH 06400 Masterpact Circuit Breaker PowerPact H/J/L Circuit Breaker FDM ESC OK I U PowerPact H/J/L Circuit Breaker Micrologic FDM ESC OK I U Micrologic PowerPact H/J/L Circuit Breaker FDM ESC OK I U Micrologic 4 Vac 5-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Modbus Communication Function Figure 7: Modbus Communication Function Connect the IMUs to a Modbus communication network with the Modbus interface module. Use an EGX00 or EGX300 gateway for connection to the Ethernet network: 0640 ENGLISH EGX00 0 03 Schneider Electric All Rights Reserved 6-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 Figure 8: Wiring Diagram for Modbus Communication Function ENGLISH 0640 Masterpact Circuit Breaker PowerPact H/J/L Circuit Breaker PowerPact H/J/L Circuit Breaker PowerPact H/J/L Circuit Breaker Modbus interface modules 7-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Metering, Display, and Modbus Communication Functions Figure 9: Metering, Display, and Modbus Communication Functions IMUs can contain metering, display, and Modbus communication functions: The metering function is by the Micrologic trip unit. The display function is by the FDM. The communication function is by the Modbus interface module. 06403 ENGLISH The IMUs have, in addition to power meter and operating data, communication and supervision functions. 0 03 Schneider Electric All Rights Reserved 8-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Rev. 0, 0/03 ENGLISH Figure 0: 06404 Masterpact Circuit Breaker Wiring Diagram for Metering, Display, and Modbus Communication Functions PowerPact H/J/L Circuit Breaker PowerPact H/J/L Circuit Breaker PowerPact H/J/L Circuit Breaker 300EGX Modbus interface modules 9-EN 0 03 Schneider Electric All Rights Reserved

> 3 0 > 0 > 3 0 A % Ir ic r 48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Architecture Section ULP System Architecture ULP Connection and Power Supply Rules Connection of an IMU in the ULP system is simple, but must comply with the rules concerning composition, ULP cables, and the ULP module power supply. ENGLISH General Rules Table 6: ULP System General Rules Rule Examples M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 > 3 0 > 0 > 3 0 A % Ir > 3 0 > 0 > 3 0 A % Ir M o c E 06443 ic r lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 > 3 0 > 0 > 3 0 A % Ir > 3 0 > 0 > 3 0 A % Ir M o c E 06443 ic r ic r lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 > 3 0 > 0 > 3 0 A % Ir > 3 0 > 0 > 3 0 A % Ir M o c E 064435 ic r ic r lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 064436 ic r An IMU contains a maximum of one ULP module of any particular type. For example, an IMU cannot contain more than one front display module (FDM) or more than one PowerPact H-, J- or L- frame circuit breaker. M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 > 3 0 > 0 > 3 0 A % Ir > 3 0 > 0 > 3 0 A % Ir M o c E ic r lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 > 3 0 > 0 > 3 0 A % Ir M o c E ic r ic r lo g 064437 i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 064438 Ir (x Io ) 4 0 5 I s d(x Ir) 6 8 M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9.5.5 3 Ir (x Io ) 064439 4 0 5 I s d(x Ir) 6 8 064440 0 03 Schneider Electric All Rights Reserved 0-EN

> 3 0 > 0 > 3 0 A % Ir > > 3 0 A > 3 0 > 0 % Ir 3 0.9 3.9.5.9.9 4.5 A 3.9 5.9 6 Ir (x Io ) 4.9 7.9 8 0 5 I s d(x Ir) % 6 8 Ir ic r ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Architecture Rev. 0, 0/03 Table 6: ULP System General Rules (continued) ENGLISH Rule Examples Connect the ULP modules in a single IMU in any order. Base the connection on the cable routing and the desired layout for the ULP modules in the switchboard. M o c E M o c E ic r ic r lo g i. 5 lo g i. 5 > 3 0 > 0.9 3.9.5.9.9 4.5 3.9 5.9 6 Ir (x Io ) 4.9 7.9 8 0 5 I s d(x Ir) 6 8 > 3 0 A > 3 0 > 0 % Ir.9 3.9.5.9.9 4.5 3.9 5.9 Ir (x Io ) 4.9 7 6 06443.9 8 0 5 I s d(x Ir) 6 8 ic r lo g i. 5 ic r lo g i. 5 > 3 0 A > 3 0 > 0 % Ir.9 3.9.5.9.9 4.5 3.9 5.9 6 Ir (x Io ) 4.9 7.9 0 5 I s d(x Ir) 6 8 8 064434 The ULP modules placed at the end of the ULP line take a ULP line termination on the unused ULP connector. Place ULP modules which have an integral ULP line termination, such as PowerPact H, J-, or L-frame circuit breakers, at the end of the ULP line. 064456 M o c E ULP Line Termination ULP Line Termination 0646 M o c E Do not connect the IMUs to one another by ULP cables. M o c E lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9 Ir (x Io ) 4 3 5.5 6 8.5 0 I s d(x Ir) > 3 0 > 0 > 3 0 A % Ir M o c E 0647 ic r lo g i. 5.9 5.9 4.9 6.9 3.9 7.9.9 8.9 Ir (x Io ) 4 3 5.5 6 8.5 0 I s d(x Ir) Use only the Modbus cable to interconnect IMUs connected to a Modbus network. -EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Architecture Length of ULP Cables Table 7: ULP Cable Length Rules Case Rule Maximum length of the ULP cable between two IMU ULP modules 3.8 ft. (0 m) Maximum length of all the ULP cables on a single IMU 65.6 ft. (0 m) Bending radius of the ULP cables.97 in. (50 mm) minimum. ENGLISH 4 Vdc Power Supply The 4 Vdc power supply connects to a single ULP module, which then distributes it to the other IMU modules through the ULP cables. Table 8: 4 Vdc Power Supply Connections Application Connection Example Standalone Architecture (See Standalone Architecture on page 3) Connect the 4 Vdc power supply to the FDM supply terminal block. 0640 0649 Other Than Standalone Architecture See Connection to the Modbus Interface Module on page 6): Connect the 4 Vdc power supply to the Modbus interface module. For more information about supplying power to the IMUs, refer to ULP System Power Supply on page 3. Summary of Connection Rules Table 9: Summary of Rules Characteristics Connection Characteristic Value Daisy-chaining of ULP cables and ULP line termination at the end of the ULP line 65.6 ft. (0 m) in total for the IMU 3.8 ft. (0 m) between two ULP modules Maximum length 39.4 ft. ( m) for the fixed part in the case of an installation with a withdrawable drawer Voltage range supported 4 Vdc -0% (9. Vdc) to 4 Vdc +0% (6.4 Vdc) Maximum consumption per IMU 300 ma (see ULP Module Consumption on page 3) 0 03 Schneider Electric All Rights Reserved -EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Architecture Rev. 0, 0/03 ULP System Power Supply ENGLISH ULP Module Consumption Power ULP modules by a 4 Vdc voltage distributed through the ULP cables. To limit voltage drops on the ULP cables and the Modbus cable, the consumption of each intelligent modular unit (IMU) is limited to 300 ma. Table 0: ULP Module Consumption Module Typical Consumption (4 Vdc at 0 C) Micrologic 5 or 6 trip unit for PowerPact H-, J-, or L-frame circuit breakers 30 ma 55 ma BSCM for PowerPact H-, J-, or L-frame circuit breakers Consumption Value 5 ma FDM ma 0 ma Modbus interface module ma 30 ma UTA tester (the UTA tester has its own power supply) 0 ma 0 ma Maximum Consumption (9. Vdc at 60 C) Power Supply Rating Table : Power Supply Rating Rules Rule The rating of the 4 Vdc power supply for the ULP modules must not exceed 3 A. The rating of the 4 Vdc power supply voltage for the furthest ULP module must be 4 Vdc +0%/-0% (9. 6.4 Vdc). Explanation This maintains coordination between the power supply current limiting and the protection integrated in the ULP modules on an overload or short-circuit. To comply with this range at the end of a Modbus cable distributing power, the 4 Vdc power supply output voltage must be regulated at: +/- 3% (3.3 V 4.7 V) for 3 A power supplies +/-5% (.8 V 5. V) for A power supplies Examples of 4 Vdc Power Supplies Table : 4 Vdc Power Supplies Description Schneider Electric : 4/30 Vdc -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 48/60 Vdc -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 00/5 Vdc -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 0/30 Vac -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 00/40 Vac -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 380/45 Vac -4 Vdc - A Primary overvoltage category IV Temperature: -5 C to +70 C Schneider Electric: 00/500 Vac - 4 Vdc - 3 A Primary overvoltage category II Temperature: 0 C to +60 C (derated to 80% of the current above 50 C) Rating A Type of Installation Installation limited to a few IMUs Part Number 68583 68584 68585 68586 68587 68589 3 A Large installation ABL8RPS4030 3-EN 0 03 Schneider Electric All Rights Reserved

48940-39-0 ULP (Universal Logic Plug) System Rev. 0, 0/03 Section ULP System Architecture Segmented Power Supply Table 3: Segmented Power Supply Cases Case When the IMUs are divided between a number of switchboards. When the total cumulative consumption of the IMUs within a single switchboard exceeds 3 A. When the IMUs communicate over Modbus using the Modbus interface module (part number TRV000), the Modbus cable distributes the 4 Vdc power. If the length of the Modbus cable is such that the voltage drop is excessive (for example, cable longer than 49. ft. (5 m) with a 3 A power supply). When an installation consists of a number of Modbus networks. Segmented Power Supply Requirement Each switchboard must have its own 4 Vdc power supply. Power the IMUs by different 4 Vdc power supplies, keeping to a maximum consumption of 3 A for each power supply. Independently-powered Modbus cable segments must be created: Only the 4 Vdc wire is interrupted between two segments The continuity of the 0 V wire (which is also the Modbus common) must be assured along the entire length of the Modbus network. The maximum number of power supply segments is three for a single Modbus network, with a maximum rating of 3 A for each power supply segment. One 4 Vdc power supply must be used for each Modbus network. Since the 0 V of the 4 Vdc power supply is also the Modbus common, the power supplies must be separated to make the Modbus networks are independent from one another. ENGLISH The 4 Vdc external power supply for the Micrologic.x and 3.x trip units for PowerPact H-, J-, and L-frame circuit breakers may be shared with the ULP/communications system. This supply is connected to earth ground as described in Table 4. NOTE: The 4 Vdc external power supply for Micrologic 0.x A/P/H trip units for Masterpact NT and NW and PowerPact P and R circuit breakers must be a separate power supply the ULP/communications power supply. Use one 4 Vdc external power supply per Micrologic 0.x A/P/H trip unit for Masterpact NT and NW and PowerPact P and R circuit breakers. This supply is NOT connected to earth ground. Connection of the 0 V WARNING HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH Connect the 0 V (Modbus common and 0 V of the 4 Vdc power supply) to the protective ground. Failure to follow these instructions can result in death, serious injury, or equipment damage. Table 4: 0 V Connection Rule Rules for Connection of the 0 V Connect the 0 V (Modbus common and 0 V of the 4 Vdc power supply) to the earth ground. Only one 0 V connection to the earth ground is accepted on a single Modbus network, at Modbus master or Ethernet gateway level, or at the top of each segment isolated by an Isolated Modbus Repeater Module. Do not connect the 4 V of the 4 Vdc power supply to the earth ground. If there are several power supply segments on a single Modbus network, the power supply on the second and third segments should not be grounded. Segments of the Modbus network that are isolated from the main trunk line and that are all located within one piece of equipment must be earth grounded within that section of equipment. 0 03 Schneider Electric All Rights Reserved 4-EN

ULP (Universal Logic Plug) System 48940-39-0 Section ULP System Architecture Rev. 0, 0/03 ENGLISH Rules for Connection to the Modbus Network Connection of Intelligent Modular Units (IMUs) This section sets out the rules for connecting intelligent modular units (IMUs) to the Modbus network. Connect intelligent modular units (IMUs) to the Modbus network with the Modbus interface module (see Modbus Interface Module on page 60). Use the Modbus cable to interconnect the IMUs, supply them with power, and connect them to the Modbus master. The maximum theoretical number of IMUs permitted on the same Modbus network is 3. To obtain acceptable communication performance (response times less than s), limit the number of IMUs on the same Modbus network to twelve. Composition of the Modbus Cable Table 5: Modbus Cable 0646. Outer sheath. Shielding braid 3. Twisted pair sheaths 4. Communication pair (white/blue) 5. Power supply pair (red/black) Description Merlin Gerin: Shielded cable with two twisted pairs. 3 4 5 L= 96.8 ft. (60 m) This cable construction is not used with the Isolated Modbus Repeater Module. Part Number 50965 Table 6: Modbus Cable Characteristics Shielded cable with twisted pairs: pair with 4 AWG (0.5 mm ) cross-section for the RS485 signal (D0, D) pair with 0 AWG (0.5 mm ) cross-section for the power supply (0 V, 4 V) Connected to the ground terminal of the Modbus interface module Shielding braid 5-pin connector External diameter: 0.35 0.38 in. (8.7 9.6 mm) Color of outer sheath: Orange The 0 V of the power supply pair is also the Modbus common, that is, the 0 V for the RS485 earth leakage protection pair (D0, D). The 0 V (Modbus common) must be distributed along the entire length of the network, right up to the Modbus master. Other Modbus cable part numbers are given in Modbus Cable Characteristics on page 99. 5-EN 0 03 Schneider Electric All Rights Reserved