Instruction Bulletin DANGER

Tamaño: px
Comenzar la demostración a partir de la página:

Download "Instruction Bulletin DANGER"

Transcripción

1 Instruction Bulletin Cedar Rapids I, US 08/01 ECN K456 L1200NE6, L1200NE6T and Lug Kits (N, NC, NE and NX Circuit Breakers and Switches) English Retain for future use. Table 1: Lug Kit Specifications Lug Kit Conductor Strip Length Wire Binding Screw Torque L1200NE6 L1200NE6T INSTLLTION (1 4) #3/0 WG 600 kcmil l/cu ( mm²) (1 4) #3/0 WG 600 kcmil Cu ( mm²) Lug Mounting Screw Torque 1-1/8 in. (29 mm) 28 lb-ft (38 N m) 250 lb-in (28 N m) 1-1/8 in. (29 mm) 28 lb-ft (38 N m) 225 lb-in (25 N m) DNGER HZRD OF ELECTRIC SHOCK, BURN, OR EXPLOSION This equipment must be installed and serviced only by qualified electrical personnel. Turn off all power supplying this equipment before working on or inside equipment. lways use a properly rated voltage sensing device to confirm power is off. Replace all devices, doors and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury. 1. Turn off all power supplying this equipment before working on or inside equipment. 2. Turn off circuit breaker. 3. Remove circuit breaker from enclosure if installed, and remove existing lugs, if installed. 4. Remove lug cover () CUTION HZRD OF EQUIPMENT DMGE Incorrect conductors can cause equipment damage. Install appropriate new lug data label(s) over existing lug data on circuit breaker. Make sure conductors are correct material and size. Failure to follow this instruction can result in equipment damage. 5. Install new lugs as shown below. 6. Torque lug mounting screws () as called out in Table Install appropriate new lug data label(s) over existing lug data on circuit breaker Schneider Electric ll Rights Reserved 1

2 L1200NE6, L1200NE6T and Lug Kits (N, NC, NE and NX Circuit Breakers and Switches) Instruction Bulletin 08/01 English WIRE INSTLLTION CUTION HZRD OF EQUIPMENT DMGE Wire strands interfering with wire binding screws can cause false torque indication. Do not allow wire strands to interfere with threads of wire binding screws. Failure to follow these instructions can result in equipment damage. 1. Install wire. See Table 1 for wire binding screw torque and strip length For L1200NE6T lugs, fasten control wire () to lug. Torque screw to 9 12 lb-in (1 1.3 N m) Square D Company PO Box Sixth St SW Cedar Rapids I US SquareD ( ) Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons Schneider Electric ll Rights Reserved

3 Boletín de instrucciones Cedar Rapids I, EU 08/01 ECN K456 ccesorios de zapatas L1200NE6, L1200NE6T y Conservar para uso futuro. Tabla 1: Especificaciones de los accesorios de zapatas Español ccesorio Conductor Sección sin aislamiento L1200NE6 L1200NE6T INSTLCIÓN (1 4) l/cu mm² (#3/0 WG 600 kcmil) (1 4) Cu mm² (#3/0 WG 600 kcmil) Par de apriete del tornillo de sujeción del cable Par de apriete del tornillo de montaje de la zapata 29 mm (1-1/8 pulg) 38 N m (28 lbs-pie) 28 N m (250 lbs-pulg) 29 mm (1-1/8 pulg) 38 N m (28 lbs-pie) 25 N m (225 lbs-pulg) PELIGRO PELIGRO DE DESCRG ELÉCTRIC, QUEMDURS O EXPLOSIÓN Solamente el personal eléctrico especializado deberá instalar y prestar servicio de mantenimiento a este equipo. Desenergice el equipo antes de realizar cualquier trabajo en él. Siempre utilice un dispositivo detector de tensión nominal adecuado para confirmar la desenergización del equipo. Vuelva a colocar todos los dispositivos, las puertas y las cubiertas antes de energizar el equipo. El incumplimiento de estas precauciones podrá causar la muerte o lesiones serias. 1. Desenergice el equipo antes de realizar cualquier trabajo en él. 2. Desconecte el interruptor automático. 3. Retire el interruptor automático del gabinete, si está instalado, y retire las zapatas existentes, si están instaladas. 4. Retire la cubierta de zapatas () PRECUCIÓN PELIGRO DE DÑO L EQUIPO Si no se utilizan los conductores correctos se puede ocasionar daño al equipo. Coloque las nuevas etiquetas de datos de las zapatas sobre las etiquetas de datos existentes en el interruptor automático. segúrese de que los conductores sean del material y tamaño correctos. El incumplimiento de esta precaución puede causar daño al equipo. 5. Instale las nuevas zapatas como se indica abajo. 6. priete los tornillos de montaje () de las zapatas según los valores indicados en la tabla Coloque las nuevas etiquetas de datos de las zapatas sobre las etiquetas de datos existentes en el interruptor automático Schneider Electric Reservados todos los derechos 3

4 ccesorios de zapatas L1200NE6, L1200NE6T y (para los int. auto. y desconectadores N, NC, NE y NX) Boletín de instrucciones 08/01 INSTLCIÓN DE CBLES Español PRECUCIÓN PELIGRO DE DÑO L EQUIPO Los hilos del cable que interfieren con los tornillos de sujeción pueden dar una indicación falsa del par de apriete. No permita que los hilos del cable interfieran con las roscas de los tornillos de sujeción del cable. El incumplimiento de esta precaución puede causar daño al equipo. 1. Instale el cable. Consulte la tabla 1 para obtener el valor de par de apriete del tornillo de sujeción del cable y la longitud sin aislamiento Para las zapatas L1200NE6T, sujete el cable de control () a la zapata. priete el tornillo de 1 a 1,3 N m (9 12 lbs-pulg) Importado en México por: Schneider Electric México, S.. de C.V. Calz. Javier Rojo Gómez Col. Gpe. del Moral México, D.F. Tel Solamente el personal especializado deberá prestar servicio de mantenimiento al equipo eléctrico. Schneider Electric no asume responsabilidad alguna por las consecuencias emergentes de la utilización de este material. Este documento no deberá utilizarse como un manual de instrucciones por aquéllos sin capacitación adecuada Schneider Electric Reservados todos los derechos

5 Directives d utilisation Cedar Rapids I, É-U 08/01 ECN K456 Kits de cosses L1200NE6, L1200NE6T et (pour interrupteurs et disjoncteurs N, NC, NE et NX) À conserver pour usage ultérieur. Tableau 1 : Spécifications des kits de cosses Kit de cosses Conducteur Longueur de dénudage L1200NE6 L1200NE6T (1 à 4) l/cu 95 à 300 mm² (n o 3/0 WG à 600 kcmil ) (1 à 4) Cu 95 à 300 mm² (n o 3/0 WG à 600 kcmil ) Couple de serrage de la vis de fixation de fils Couple de serrage de la vis de montage de cosse 29 mm (1-1/8 po) 38 N m (28 lb-pi) 28 N m (250 lb-po) 29 mm (1-1/8 po) 38 N m (28 lb-pi) 25 N m (225 lb-po) Français INSTLLTION DNGER RISQUE D ÉLECTROCUTION, DE BRÛLURES OU D EXPLOSION L installation et l entretien de cet appareil ne doivent être effectués que par du personnel qualifié. Coupez toute alimentation de cet appareil avant d y travailler. Utilisez toujours un dispositif de détection de tension à valeur nominale appropriée pour s assurer que l alimentation est coupée. Replacez tous les dispositifs, les portes et les couvercles avant de mettre l appareil sous tension. Si ces précautions ne sont pas respectées, cela entraînera la mort ou des blessures graves. 1. Couper toute alimentation de cet appareil avant d y travailler. 2. Mettre le disjoncteur hors tension. 3. Enlever le disjoncteur du coffret, s il est installé et retirer les cosses existantes, si installées. 4. Retirer le couvercle des cosses () TTENTION RISQUE DE DOMMGES MTÉRIELS Des conducteurs incorrects peuvent occasionner des dommages à l'appareil. Installez les nouvelles étiquettes des données de cosses appropriées sur les données de cosses existantes du disjoncteur. ssurezvous que le matériau et la taille des conducteurs sont corrects. Si cette précaution n est pas respectée, cela peut entraîner des dommages matériels. 5. Installer les nouvelles cosses de la façon illustrée ci-dessous. 6. Voir le tableau 1 pour obtenir le couple de serrage des vis de montage des cosses. 7. Installer les nouvelles étiquettes de données de cosses appropriées sur les données de cosses existantes du disjoncteur Schneider Electric Tous droits réservés 5

6 Kits de cosses L1200NE6, L1200NE6T et (pour interrupteurs et disjoncteurs N, NC, NE et NX) Directives d utilisation 08/01 INSTLLTION DES FILS Français TTENTION RISQUE DE DOMMGES MTÉRIELS Les torons du conducteur qui s engagent dans les vis de fixation de fils causeront une indication erronée du couple. Ne permettez pas que les torons du conducteur s'engagent dans le filetage de la vis de fixation. Si cette précaution n est pas respectée, cela peut entraîner des dommages matériels. 1. Installer les fils.voir le tableau 1 pour obtenir la longueur de dénudage des fils et le couple de serrage de la vis de fixation de fils Dans le cas de cosses L1200NE6T, fixer le fil de commande () à la cosse. Serrer la vis à un couple de 1 à 1,3 N m (9 à 12 lb-po) Schneider Canada Inc. 19 Waterman venue, M4B 1 Y2 Toronto, Ontario L entretien du matériel électrique ne doit être effectué que par du personnel qualifié. Schneider Electric n assume aucune responsabilité des conséquences éventuelles découlant de l utilisation de cette documentation. Ce document n est pas destiné à servir de manuel d utilisation aux personnes sans formation Schneider Electric Tous droits réservés

Instruction Bulletin DANGER CAUTION. S33930 Sub-feed Lugs SUB-FEED LUG INSTALLATION. 48049-250-01 Cedar Rapids IA, USA 05/01 ECN K512 English

Instruction Bulletin DANGER CAUTION. S33930 Sub-feed Lugs SUB-FEED LUG INSTALLATION. 48049-250-01 Cedar Rapids IA, USA 05/01 ECN K512 English Instruction Bulletin S33930 Sub-feed Lugs 48049-250-01 Cedar Rapids I, US 05/01 ECN K512 English Retain for future use. DNGER HZRD OF ELECTRIC SHOCK, BURN, OR EXPLOSION This equipment must be installed

Más detalles

Line Neutral Lug Replacement Kit for 200 A Underground Feed Combination Service Entrance Device Class 4120

Line Neutral Lug Replacement Kit for 200 A Underground Feed Combination Service Entrance Device Class 4120 Instruction Bulletin 40273-361-01 01/2004 Lexington, KY, USA Line Neutral Lug Replacement Kit for 200 A Underground Feed Combination Service Entrance Device Class 4120 Retain for future use. ENGLISH Table

Más detalles

General Information Información general Généralités

General Information Información general Généralités Instruction Bulletin Boletín de instrucciones Directives d'utilisation 480-929-04 Rev. 01, 03/11 Replaces / Reemplaza / Remplace 480-929-04 ECN 094D, 03/07 Power Distribution Connectors for Circuit Breakers

Más detalles

Meter Socket Replacement Kit for 200 A Ringless Horn Bypass Combination Service Entrance Device Class 4120

Meter Socket Replacement Kit for 200 A Ringless Horn Bypass Combination Service Entrance Device Class 4120 Instruction Bulletin 40273-371-01 01/2004 Lexington, KY, USA Meter Socket Replacement Kit for 200 A Ringless Horn Bypass Combination Service Entrance Device Class 4120 ENGLISH Retain for future use. Table

Más detalles

Panneaux de distribution NF à largeur de colonne Information supplémentaire

Panneaux de distribution NF à largeur de colonne Information supplémentaire NF Column-Width Panelboards Supplemental Information Tableros de alumbrado y distribución NF de ancho de columna Información adicional Panneaux de distribution NF à largeur de colonne Information supplémentaire

Más detalles

General Information Información general Généralités. Para uso especial no para uso general

General Information Información general Généralités. Para uso especial no para uso general Instruction Bulletin Boletín de instrucciones Directives d'utilisation 480-929-04 Rev. 02, 04/15 Replaces / Reemplaza / Remplace 480-929-04 Rev. 01, 03/11 Power Distribution Connectors for Circuit Breakers

Más detalles

Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero QMB Clase 4620

Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero QMB Clase 4620 Boletín de instrucciones 80043-268-06 05/2009 Peru, IN, EUA Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero QMB Clase 4620 Conservar

Más detalles

/2008 Cedar Rapids, IA, USA. Boletín de instrucciones. Directives d'utilisation. Instruction Bulletin

/2008 Cedar Rapids, IA, USA. Boletín de instrucciones. Directives d'utilisation. Instruction Bulletin Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48940-56-0 05/008 Cedar Rapids, IA, USA Plug-in Base Kit for H- and J-frame Molded Case Circuit Breakers Accesorio de base para enchufar

Más detalles

VC400LA3, VC400LA35, VC400LA5, VC400LA7, CVC400LA3, and CVC400LA5 VERSAtile Lug Kits (Series 3 and 4 LA, LH, and Q4 Circuit Breakers)

VC400LA3, VC400LA35, VC400LA5, VC400LA7, CVC400LA3, and CVC400LA5 VERSAtile Lug Kits (Series 3 and 4 LA, LH, and Q4 Circuit Breakers) Instruction ulletin 48040-699-03 Rev. 01, 11/010 Replaces 48040-699-03 ECN K450, 11/001, 5,, VC400L7,, and VERStile Lug Kits (Series 3 and 4 L, LH, and Q4 Circuit reakers) ENGLISH Retain for future use.

Más detalles

Boletín de instrucciones Kit de extensión de riel y marco de 152, 305, 457 mm Instalación en un tablero de alumbrado y distribución NF Clase 1670

Boletín de instrucciones Kit de extensión de riel y marco de 152, 305, 457 mm Instalación en un tablero de alumbrado y distribución NF Clase 1670 Boletín de instrucciones Kit de extensión de riel y marco de 152, 305, 457 mm Instalación en un tablero de alumbrado y distribución NF Clase 1670 80043-763-01 06/2008 Peru, IN, EUA Conservar para uso futuro.

Más detalles

Introduction Introducción Introduction

Introduction Introducción Introduction Instruction ulletin oletín de instrucciones Directives d'utilisation 48049-335-01 Replaces / Reemplaza / Remplace 48049-335-01 Rev. 03, 09/2010 Masterpact MP/M Retrofit Kits Kits de modernización (retrofit)

Más detalles

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT Connector Conector Connecteur

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT Connector Conector Connecteur Instruction ulletin oletín de instrucciones Directives d'utilisation Push-in and Ring Terminal Connectors for MSTERPCT NW Drawout Circuit reakers Conectores de terminal de anillo y de encaje a presión

Más detalles

Instruction Bulletin Boletín de instrucciones Directives d'utilisation 80043-761-01

Instruction Bulletin Boletín de instrucciones Directives d'utilisation 80043-761-01 NF Panelboard Mechanical Main Lug Kit (125, 250, 400, and 600 Amp) Kit de zapatas mecánicas principales para tableros NF (de 125, 250, 400 y 600 A) Kit de cosses principales mécaniques pour panneau de

Más detalles

Cosses à compression des panneaux de distribution I-Line

Cosses à compression des panneaux de distribution I-Line I-Line Panelboards Compression Lugs Zapatas compresión para tableros I-Line Cosses à compression s panneaux distribution I-Line Data Bulletin Boletín datos Bulletin données 2110DB0901 Retain for Future

Más detalles

Introduction Introducción Introduction

Introduction Introducción Introduction Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48049-299-01 Rev. 04, 07/2014 Replaces / Reemplaza / Remplace 48049-299-01 Rev. 0, 05/2014 Masterpact NW Circuit Breaker UL/NSI Cluster

Más detalles

DANGER / PELIGRO / DANGER

DANGER / PELIGRO / DANGER Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48840-058-02 09/2003 Cedar Rapids, I, US ECN N351 Two-pole Homeline Circuit Breaker with Class Ground-fault Circuit Interrupter Interruptor

Más detalles

1/4-Turn Fasteners for Panelboards Class 1630, 1640, 1670, 2110. Sujetadores de 1/4 de vuelta para tableros de alumbrado Clase 1630, 1640, 1670, 2110

1/4-Turn Fasteners for Panelboards Class 1630, 1640, 1670, 2110. Sujetadores de 1/4 de vuelta para tableros de alumbrado Clase 1630, 1640, 1670, 2110 Instruction Bulletin Boletín de instrucciones Directives d'utilisation Retain for Future Use. / Conservar para uso futuro. / À conserver pour usage ultérieur. 1/4-Turn Fasteners for Panelboards Class 1630,

Más detalles

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT Instruction ulletin oletín de instrucciones Directives d'utilisation 48049-236-01 03/2006 Cedar Rapids, Iowa, US ECN 658C Replaces / Reemplaza / Remplace 48049-236-01 09/2001 Spring Charging Motor (MCH)

Más detalles

A B. Shunt Trip Installation 1. Install shunt trip (A) and coil clearing switch (B). Install screws (C). Left-Side View.

A B. Shunt Trip Installation 1. Install shunt trip (A) and coil clearing switch (B). Install screws (C). Left-Side View. Instruction ulletin Field-installable Shunt Trip or uxiliary ccessory (P, PH, P, P, PX, SP, SPH, and SP ircuit reakers) Retain for future use. INSTLLTION DNGR HZRD OF LTRI SHOK, URN, OR XPLOSION This equipment

Más detalles

QMB Panelboards Blank Fillers Installation of QMB1BLW, QMB3BLW, QMB6BLW, and QMB15BLW onto a QMB Panelboard

QMB Panelboards Blank Fillers Installation of QMB1BLW, QMB3BLW, QMB6BLW, and QMB15BLW onto a QMB Panelboard QMB Panelboards Blank Fillers Installation of QMB1BLW, QMB3BLW, QMB6BLW, and QMB15BLW onto a QMB Panelboard Placas de relleno para los tableros de alumbrado y distribución QMB Instalación de los kits QMB1BLW,

Más detalles

NQ Adapter Bracket Kit Installation Instructions Class 1640

NQ Adapter Bracket Kit Installation Instructions Class 1640 Instruction Bulletin 80043-811-01 NQ Adapter Bracket Kit Installation Instructions Class 1640 Retain for future use. ENGLISH Introduction Safety Precautions This bulletin contains instructions for the

Más detalles

Generator Interlock Kit Accesorio de enclavamiento del generador Kit d interverrouillage de la génératrice

Generator Interlock Kit Accesorio de enclavamiento del generador Kit d interverrouillage de la génératrice Instruction Bulletin Boletín de instrucciones Directives d'utilisation Generator Interlock Kit Accesorio de enclavamiento del generador Kit d interverrouillage de la génératrice Class Clase Classe Type

Más detalles

Tableros de alumbrado y distribución I-Line Instalación de la conexión de neutro y de tierra del transformador de corriente

Tableros de alumbrado y distribución I-Line Instalación de la conexión de neutro y de tierra del transformador de corriente I-Line Panelboards Current Transformer Neutral Bonding Installation Tableros de alumbrado y distribución I-Line Instalación de la conexión de neutro y de tierra del transformador de corriente Panneau de

Más detalles

Catalog Prefix: AOF and COF Class 5600 Supplement to Instruction Bulletin 45123-921-01 for Achieving IP-66 Rating

Catalog Prefix: AOF and COF Class 5600 Supplement to Instruction Bulletin 45123-921-01 for Achieving IP-66 Rating Instruction Bulletin Bulletin No. 45123-922-01** July 1997 Oxford, OH, USA I-LINE II OUTDOOR FEEDER BUSWAY Catalog Prefix: AOF and COF Class 5600 Supplement to Instruction Bulletin 45123-921-01 for Achieving

Más detalles

Qwik Flange Terminal Installation I-Line II Busway Joint Connection to the Equipment Termination

Qwik Flange Terminal Installation I-Line II Busway Joint Connection to the Equipment Termination Qwik Flange Terminal Installation I-Line II Busway Joint Connection to the Equipment Termination Instalación del conector Qwik Flange Conexión de la junta de electroducto I-Line II a la terminación del

Más detalles

NECESSARY TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES Screwdriver (Pozidriv No. 2 or 3 pt., or slotted)

NECESSARY TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES Screwdriver (Pozidriv No. 2 or 3 pt., or slotted) nstruction ulletin oletín de instrucciones irectives d'utilisation 48049-240-01 01/2006 edar Rapids,, US EN 645 Replaces / Reemplaza / Remplace 48049-240-01 02/2001 S47512 Electrical losing Push utton

Más detalles

Instruction Bulletin. Class 2746/6037. Introduction ENGLISH /2009 Hopkins, SC USA. Retain for future use.

Instruction Bulletin. Class 2746/6037. Introduction ENGLISH /2009 Hopkins, SC USA. Retain for future use. Instruction Bulletin 80298-175-01 12/2009 Hopkins, SC USA Installation of Main Through Bus Bracing in an Auxiliary Section For Power-Style QED-6 Switchboards and Power-Zone 4 Low Voltage Switchgear Class

Más detalles

ENA. POWERLOGIC Enercept Network Adapter Adaptador de red Enercept (instructionnes en español: página 5) ENGLISH INTRODUCTION INSTALLING THE ENA

ENA. POWERLOGIC Enercept Network Adapter Adaptador de red Enercept (instructionnes en español: página 5) ENGLISH INTRODUCTION INSTALLING THE ENA Instruction Bulletin Boletín de instrucciones ENGLISH Bulletin No. 63230-216-203/A2 4/2000 POWERLOGIC Enercept Network Adapter Adaptador de red Enercept (instructionnes en español: página 5) INTRODUCTION

Más detalles

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT

KIT CONTENTS CONTENIDO DEL ACCESORIO CONTENU DU KIT Instruction ulletin oletín de instrucciones Directives d'utilisation 48049-293-02 01/2006 Cedar Rapids, I, US ECN 645C Replaces / Reemplaza / Remplace 48049-293-02 06/2003 S48188 and S47485 Modbus Circuit

Más detalles

Instruction Bulletin. Control Bus for use with POWERLINK G3 Systems / para itilizarse con los sistemas POWERLINK G3 Class 1210 ENGLISH

Instruction Bulletin. Control Bus for use with POWERLINK G3 Systems / para itilizarse con los sistemas POWERLINK G3 Class 1210 ENGLISH Instruction Bulletin 63249-400-200/A3 LaVergne, TN, USA Replaces 63249-400-200/A2 Control Bus for use with POWERLINK G3 Systems / para itilizarse con los sistemas POWERLINK G3 Class 1210 ENGLISH Retain

Más detalles

Instruction Bulletin. Power Supply. for use with POWERLINK G3 systems para utilizarse en los sistemas POWERLINK G3 (instructionnes en español: page 9)

Instruction Bulletin. Power Supply. for use with POWERLINK G3 systems para utilizarse en los sistemas POWERLINK G3 (instructionnes en español: page 9) Instruction Bulletin 63249-402-200/A2 1/2002 Power Supply for use with POWERLINK G3 systems para utilizarse en los sistemas POWERLINK G3 (instructionnes en español: page 9) CONTENTS CONTENTS...............................................1

Más detalles

DANGER / PELIGRO / DANGER

DANGER / PELIGRO / DANGER Instruction Bulletin Boletín de instrucciones Directives d'utilisation Home Electronics Protective Device (HEPD) Dispositivo de protección de equipo electrónico del hogar (HEPD) Dispositif de protection

Más detalles

KIT CONTENTS CONTENIDO DEL KIT CONTENU DU KIT 250 800 A 1200 A REQUIRED TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES

KIT CONTENTS CONTENIDO DEL KIT CONTENU DU KIT 250 800 A 1200 A REQUIRED TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES Instruction ulletin oletín de instrucciones Directives d'utilisation 48049-147-02 Rev. 02, 12/2010 Replaces / Reemplaza / Remplace 48049-147-02 Rev. 01, 10/2010 Compression Lug Kits for M-, P-, and R-frame

Más detalles

INSTALLATION INSTRUCTION Vogue WS-3120

INSTALLATION INSTRUCTION Vogue WS-3120 WS-3120 WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance

Más detalles

Instruction Bulletin. PowerPact M-frame Circuit Breakers

Instruction Bulletin. PowerPact M-frame Circuit Breakers Instruction ulletin PowerPact M-frame Circuit reakers Retain for future use. 48049-251-01 Replaces 48049-251-01 ECN 733C, 02/2006 ENGLISH Necessary Tools dditional Information Install Circuit reaker 1.

Más detalles

DANGER PELIGRO DE DESCARGA ELÉCTRICA, EXPLOSIÓN O DESTELLO POR ARQUEO

DANGER PELIGRO DE DESCARGA ELÉCTRICA, EXPLOSIÓN O DESTELLO POR ARQUEO 80043-764-03 08/2009 Peru, IN, EUA Boletín de instrucciones Kit adaptador de interruptor automático principal marco H o J para tableros NF Instalación en un tablero de alumbrado y distribución NF Clase

Más detalles

Square D Intelligent Load Center QO Indoor Load Centers, Class 1130

Square D Intelligent Load Center QO Indoor Load Centers, Class 1130 Square D Intelligent Load Center QO Indoor Load Centers, Class 1130 Centro de carga inteligente Square D Centros de carga QO para interiores, clase 1130 Instruction Bulletin Boletín de instrucciones Retain

Más detalles

Date Code / Código de fecha / Code de date. All / Todos / Tous. 100 A and / y / et 250 A All / Todos / Tous

Date Code / Código de fecha / Code de date. All / Todos / Tous. 100 A and / y / et 250 A All / Todos / Tous Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48049-145-03 05/2008 Cedar Rapids, IA ECN 585D Replaces / Reemplaza / Remplace 48049-145-03 01/2007 Sensor Plug Replacement for Micrologic

Más detalles

Soportes de montaje plano/de canto de electroducto I-LINE II (no. de catálogo HF13SH a HF88SH) Aplicaciones sísmicas

Soportes de montaje plano/de canto de electroducto I-LINE II (no. de catálogo HF13SH a HF88SH) Aplicaciones sísmicas I-Line II Busway Flatwise/Edgewise Hangers (Catalog No. HF13SH through HFSH) Seismic Application Soportes de montaje plano/de canto de electroducto I-LINE II (no. de catálogo HF13SH a HFSH) Aplicaciones

Más detalles

PRECAUTIONS PRECAUCIONES PRÉCAUTIONS

PRECAUTIONS PRECAUCIONES PRÉCAUTIONS Instruction Bulletin Boletín de instrucciones Directives d'utilisation 40281-607-01 06/2006 Lexington, KY, USA QO and Homeline Outdoor Load Centers Centros de carga QO y Homeline para exteriores Centres

Más detalles

APLICACIONES APPLICATIONS

APLICACIONES APPLICATIONS Instruction ulletin oletín de instrucciones Directives d'utilisation 05/2009 edar Rapids, Iowa, US PowerPact Rev. 00 D-Frame Mission ritical ircuit reaker Installation Instalación del interrupr aumático

Más detalles

Installation Instalación Installation 安 装

Installation Instalación Installation 安 装 Instruction Bulletin Boletín de instrucciones Directives d'utilisation 说 明 手 册 48049-271-02 Rev. 02, 02/2013 Replaces / Reemplaza / Remplace / 更 新 48049-271-02, 04/2011 Alarm Switch (SD), Overcurrent Trip

Más detalles

Light Package Switches Interruptores ligeros del Paquete

Light Package Switches Interruptores ligeros del Paquete Hoffman Enclosures Inc. 2100 Hoffman Way Anoka, MN 55303 1745 (763) 422 2211 www.hoffmanonline.com Light Package Switches Interruptores ligeros del Paquete Rev. B 111550 2004 Hoffman Enclosures Inc. P/N

Más detalles

U.S. Cat. No. H_X _ L_X _ N_Y3 H_Y3 L_Y3 HFS_S_50L LFS3S250 N_N_B _ H_N_B _ L_N_B _ N_X _

U.S. Cat. No. H_X _ L_X _ N_Y3 H_Y3 L_Y3 HFS_S_50L LFS3S250 N_N_B _ H_N_B _ L_N_B _ N_X _ s Circuit Breaker, Frame DG, FG Interruptor, Caja Base DG, FG Disjoncteur, de Base DG, FG Item: U.S. Cat. No. HDS_S_50L HFS_S_50L LFSS50 N_N_B _ H_N_B _ L_N_B _ N_X _ H_X _ L_X _ N_Y H_Y L_Y VL_5 -_ KE

Más detalles

NECESSARY TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES. Desatornillador: Pozidriv no. 2 ó 3, o de punta plana Ranurado de 3/32 x 3 pulg

NECESSARY TOOLS HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES. Desatornillador: Pozidriv no. 2 ó 3, o de punta plana Ranurado de 3/32 x 3 pulg Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48049-139-02 06/2003 edar Rapids, IA USA EN 009B Modbus ircuit Breaker ommunication Module (BM) For Masterpact NW ircuit Breakers

Más detalles

DANGER / PELIGRO / DANGER

DANGER / PELIGRO / DANGER Instruction Bulletin Boletín de instrucciones Directives d'utilisation 48049-034-04 11/2002 Cedar Rapids, IA, USA LA, LAMC, LH, LHMC, SLA and Q4 Circuit Breakers Interruptores automáticos LA, LAMC, LH,

Más detalles

Instruction Bulletin Ground-fault Interface Module with Current Sensor for Masterpact NW, R-frame and NS1600b NS3200 Circuit Breakers

Instruction Bulletin Ground-fault Interface Module with Current Sensor for Masterpact NW, R-frame and NS1600b NS3200 Circuit Breakers Instruction Bulletin Ground-fault Interface with Current Sensor for Masterpact NW, R-frame and NS600b NS00 Circuit Breakers 809-8-0 06/00 Cedar Rapids, I, US ECN 08B ENGLISH Retain for future use. GENERL

Más detalles

Instruction Bulletin. QO and Homeline Load Centers Installation Class 1100

Instruction Bulletin. QO and Homeline Load Centers Installation Class 1100 Instruction Bulletin 07/2012 QO and Homeline Load Centers Installation Class 1100 Retain for future use. Introduction ENGLISH This bulletin contains instructions for the installation and operation of QO

Más detalles

Introduction Introducción Introduction

Introduction Introducción Introduction Instruction Bulletin Boletín de instrucciones Directives d'utilisation 30072-009-63 Rev. 01, 05/2011 Raleigh, NC, USA Replaces / Reemplaza / Remplace 30072-009-63D and 30072-009-64C 07/1989 Flange-Mounted,

Más detalles

Specification Chart Tableau des spécifications Cuadro de especificaciones GASOLINE ENGINE (MOTEUR À ESSENCE) (MOTOR DE GASOLINA)

Specification Chart Tableau des spécifications Cuadro de especificaciones GASOLINE ENGINE (MOTEUR À ESSENCE) (MOTOR DE GASOLINA) Operator-Parts Manual Manuel de l opérateur - Manuel de pièces Manual del operador - Manual de piezas 200-2416 Revision A Oilless, Single Stage, Direct Drive, Gasoline Engine Driven Air Compressor Sans

Más detalles

Lever Bypass Meter Socket Assemblies for Power-Style QED Commercial Multi-Metering

Lever Bypass Meter Socket Assemblies for Power-Style QED Commercial Multi-Metering Lever Bypass Meter Socket Assemblies for Power-Style QED Commercial Multi-Metering Ensambles de base de medición con derivación tipo palanca para múltiples medidores comerciales Power-Style QED Assemblages

Más detalles

Módulo de tensión/alimentación POWERLOGIC (para los monitores de circuitos serie 2000)

Módulo de tensión/alimentación POWERLOGIC (para los monitores de circuitos serie 2000) Instruction Bulletin Boletín de instrucciones Directives d utilisation POWERLOGIC Voltage/Power Module (for Series 2000 Circuit Monitors) Módulo de tensión/alimentación POWERLOGIC (para los monitores de

Más detalles

ARCHITECT S SUPPLEMENTAL INSTRUCTIONS ASI # 018

ARCHITECT S SUPPLEMENTAL INSTRUCTIONS ASI # 018 ARCHITECT S SUPPLEMENTAL INSTRUCTIONS ASI # 018 PROJECT: 12.02 - Odell Brewhouse Expansion INITIATION DATE: March 19, 2013 OWNER: Odell Brewing Company ARCHITECT: RB+B Architects, Inc. 800 Lincoln Avenue

Más detalles

Beckett 5 Shelf Bookcase / Bibliothéque 5 Étagéres / 5 Estantería Librero

Beckett 5 Shelf Bookcase / Bibliothéque 5 Étagéres / 5 Estantería Librero English This page lists the contents included in the box. Please take time to identify the hardware as well as the individual components of the product. As you unpack and prepare for assembly, place the

Más detalles

Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero QMB

Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero QMB QMB Panelboards Solid Neutral and Bonding Components Installation onto a QMB Panelboard Componentes de conexión y neutro sólido para los tableros de alumbrado y distribución QMB Instalación en un tablero

Más detalles

Introduction Introducción Introduction

Introduction Introducción Introduction Instruction Bulletin Boletín de instrucciones Directives d'utilisation 30 or 60 A Non-Fusible MD50 Motor Disconnect Switch Desconectador seccionador de motores MD50 de 30 ó 60 A sin fusibles Sectionneur

Más detalles

This bulletin contains instructions for the installation and operation of QO and Homeline load centers. DANGER

This bulletin contains instructions for the installation and operation of QO and Homeline load centers. DANGER Instruction Bulletin QO and Homeline Load Centers Class 1100 Retain for future use. 40271-419-04 06/2005 Lexington, KY, USA Replaces 40271-419-04 dated 03/2005 INTRODUCTION This bulletin contains instructions

Más detalles

Blair Storage Bed / Lit avec Rangement / Cama con Almacenamiento - Queen, King

Blair Storage Bed / Lit avec Rangement / Cama con Almacenamiento - Queen, King English This page lists the contents included in the box. Please take time to identify the hardware as well as the individual components of the product. s you unpack and prepare for assembly, place the

Más detalles

QMB Panelboards Tableros de alumbrado y distribución QMB Panneaux de distribution QMB

QMB Panelboards Tableros de alumbrado y distribución QMB Panneaux de distribution QMB QMB Panelboards Tableros de alumbrado y distribución QMB Panneaux de distribution QMB Instruction Bulletin Boletín de instrucciones Directives d utilisation 80043-334-06 Retain in the directory card pocket

Más detalles

Adapter Boards for PowerLogic BCPMSC

Adapter Boards for PowerLogic BCPMSC Installation Guide Z2058-0A Adapter Boards for PowerLogic BCPMSC Panelboard Monitoring System with Split-Core CTs Introduction Dimensions The PowerLogic Adapter Boards for PowerLogic BCPMSC allow easy

Más detalles

Connecting Series S3-Link Software to the Motorpact Reduced Voltage Soft Start (RVSS) Unit

Connecting Series S3-Link Software to the Motorpact Reduced Voltage Soft Start (RVSS) Unit Connecting Series S3-Link Software to the Motorpact Reduced Voltage Soft Start (RVSS) Unit Cómo conectar el software Link serie S3 al arrancador suave a tensión reducida (RVSS) Motorpact Connexion du logiciel

Más detalles

ROCK N STEREO SOUND DESK

ROCK N STEREO SOUND DESK Read and save these instructions ROCK N STEREO SOUND DESK RTA-M1102-BK INSTRUCTIONS TABLE OF CONTENTS PACKAGE INCLUDES Package Includes... 2 Specifications... 2 Product Parts List... 3 1 2 3 Product Details...

Más detalles

Instruction Bulletin DANGER DANGER. 30-Pin Mobile to RS-485 Converter, Model VW3A8151R20U. Precautions ENGLISH ESPAÑOL FRANÇAIS EAV44179 09/2013

Instruction Bulletin DANGER DANGER. 30-Pin Mobile to RS-485 Converter, Model VW3A8151R20U. Precautions ENGLISH ESPAÑOL FRANÇAIS EAV44179 09/2013 Instruction Bulletin EAV44179 09/2013 30-Pin Mobile to RS-485 Converter, Model VW3A8151R20U Retain for future use. ENGLISH Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Read and

Más detalles

40271-887-03 03/2005 Lexington, KY, USA Replaces 40271-887-02 dated 02/2002 QO and Homeline Outdoor Load Centers Class 1100 DANGER

40271-887-03 03/2005 Lexington, KY, USA Replaces 40271-887-02 dated 02/2002 QO and Homeline Outdoor Load Centers Class 1100 DANGER Instruction Bulletin 40271-887-03 03/2005 Lexington, KY, USA Replaces 40271-887-02 dated 02/2002 QO and Homeline Outdoor Load Centers Class 1100 Retain for future use. INTRODUCTION This bulletin contains

Más detalles

Clear Cover for PowerLogic BCPM and BCPMSC

Clear Cover for PowerLogic BCPM and BCPMSC Installation Guide Clear Cover for PowerLogic BCPM and BCPMSC Panelboard Monitoring Systems Z0583-0A 08/010 50 Introduction The BCPMCOVER is a protective cover compatible with all BCPM and BCPMSC boards.

Más detalles

Type VR Lift Trucks Montacargas tipo VR Chariot élévateur type VR

Type VR Lift Trucks Montacargas tipo VR Chariot élévateur type VR Type VR Lift Trucks Montacargas tipo VR Chariot élévateur type VR Instruction Bulletin Boletín de instrucciones Directives d'utilisation 6055-54 10/2011 Retain for Future Use. / Conservar para uso futuro.

Más detalles

ENGLISH DANGER. Float Switch Interruptor de flotador Interrupteur à flotteur. Instruction Boletín de Directives Bulletin instrucciones d'utilisation

ENGLISH DANGER. Float Switch Interruptor de flotador Interrupteur à flotteur. Instruction Boletín de Directives Bulletin instrucciones d'utilisation Instruction Boletín de Directives Bulletin instrucciones d'utilisation Bulletin No. 5157-009-01B 10/00 Raleigh, NC, USA Replaces / Reemplaza / Remplace 5057-009A 11/98 Float Switch Interrupteur à flotteur

Más detalles

*P515-814* L/LV9000-Series. 2 All functions Todas las funciones Toutes fonctions. 1 All functions Todas las funciones Toutes fonctions

*P515-814* L/LV9000-Series. 2 All functions Todas las funciones Toutes fonctions. 1 All functions Todas las funciones Toutes fonctions *P515-814* P515-814 Knob and Rose Perilla y Embellecedor Bouton et Rosette L/LV9000-Series Installation Instructions Instrucciones de Instalación Instructions d Installation A. Lockcase and mounting screws

Más detalles

microsoft.com/hardware/support

microsoft.com/hardware/support 2015 Microsoft microsoft.com/hardware/support X20-43694-01 Back Cover Front Cover K65 Set up Note: You can wirelessly connect Wi-Fi CERTIFIED Miracast enabled devices to a TV or monitor (available HDMI

Más detalles

INSTALLATION INSTRUCTIONS ECLIPSE FUEL DOOR PART # MZ313512

INSTALLATION INSTRUCTIONS ECLIPSE FUEL DOOR PART # MZ313512 INSTALLATION INSTRUCTIONS ECLIPSE FUEL DOOR PART # MZ313512 APPLICATION Mitsubishi Eclipse TOOLS REQUIRED Socket Wrench with extension and 10 mm socket Small Screwdriver Soft Cloth Cleaning Solution BILL

Más detalles

Instruction Bulletin. General Purpose Low Voltage Transformers Indoor/Outdoor, Encapsulated, 600 V Class 7400

Instruction Bulletin. General Purpose Low Voltage Transformers Indoor/Outdoor, Encapsulated, 600 V Class 7400 Instruction Bulletin General Purpose Low Voltage Transformers Indoor/Outdoor, Encapsulated, 600 V Class 7400 39000-243-01A 04/2006 Huntington, IN, USA Replaces 39000-243-01, 05/2000 ENGLISH Retain for

Más detalles

Cables de expansión del bus de comunicación 1769 Compact I/O

Cables de expansión del bus de comunicación 1769 Compact I/O Instrucciones para la instalación Cables de expansión del bus de comunicación 1769 Compact I/O (No. de cat. 1769-CRR1, -CRR3, -CLL1, -CLL3, -CRL1, -CRL3) Contenido... Para obtener información adicional...

Más detalles

INTRODUCCIÓN. Este boletín incluye instrucciones de montaje, modificación y solicitud de piezas.

INTRODUCCIÓN. Este boletín incluye instrucciones de montaje, modificación y solicitud de piezas. Instruction Boletín de Directives Bulletin instrucciones d'utilisation Ref. / réf. AS 007-0-57B Raleigh, NC, USA 5/00 Replaces / Reemplaza / Remplace 007-0-57A /0 Electrically Held AC Magnetic Lighting

Más detalles

IMPORTANT! CONSERVER POUR UNE UTILISATION ULTÉRIEURE LIRE SOIGNEUSEMENT IMPORTANT - KEEP FOR FUTURE REFERENCE - READ CAREFULLY WARNING AVERTISSEMENT!

IMPORTANT! CONSERVER POUR UNE UTILISATION ULTÉRIEURE LIRE SOIGNEUSEMENT IMPORTANT - KEEP FOR FUTURE REFERENCE - READ CAREFULLY WARNING AVERTISSEMENT! PATRULL KLÄMMA ENGLISH IMPORTANT - KEEP FOR FUTURE REFERENCE - READ CAREFULLY This gate or enclosure is designed for doorways and stair openings from 73 cm (28 3/4") to 87 cm (34 1/4") for children from

Más detalles

Instruction Bulletin. Commercial Multi-Metering Transition Section

Instruction Bulletin. Commercial Multi-Metering Transition Section Instruction Bulletin Commercial Multi-Metering Transition Section Class 2756 80248-661-02 07/2007 Smyrna, TN, USA Replaces 80248-661-01 12/1994 ENGLISH Retain for future use. Introduction Equipment Preparation

Más detalles

MT442 MT642 U S E R S M A N U A L

MT442 MT642 U S E R S M A N U A L T I L T S L I M M O U N T Display Size: 24-55 Maximum load: 70 lbs / 32 kg VESA Patterns: 75 x 75 to 400 x 400 Display Size: 30-65 Maximum load: 75 lbs / 34 kg VESA Patterns: 75 x 75 to 600 x 400 MT442

Más detalles

KTM 02 Termostato analógico Analogic thermostat

KTM 02 Termostato analógico Analogic thermostat KTM 02 Termostato analógico Analogic thermostat Termostato analógico Índice Especificaciones técnicas 3 Descripción 3 Instalación 3 Contents Technical Specifications 5 Application 5 Installation 5 Manual

Más detalles

Instruction Bulletin CAUTION. Remote Monitoring Unit IMA, EMA, EBA and HWA Series Transient Voltage Surge Suppressor (TVSS) Class 1310 PRECAUTIONS

Instruction Bulletin CAUTION. Remote Monitoring Unit IMA, EMA, EBA and HWA Series Transient Voltage Surge Suppressor (TVSS) Class 1310 PRECAUTIONS Instruction Bulletin Bulletin No. 8-007A /0 Raleigh, NC, USA ing Unit IMA, EMA, EBA and HWA Series Transient Voltage Surge Suppressor (TVSS) Class 30 PRECAUTIONS CAUTION NOT RATED FOR OUTDOOR USE Intended

Más detalles

Instruction Bulletin. R-frame and NS1600b NS3200 Circuit Breakers DANGER DANGER NECESSARY TOOLS INSTALLATION

Instruction Bulletin. R-frame and NS1600b NS3200 Circuit Breakers DANGER DANGER NECESSARY TOOLS INSTALLATION Instruction Bulletin R-frame and NS1600b NS3200 Circuit Breakers 48049-243-04 Cedar Rapids, I, US ECN 364B Replaces 48049-243-03 04/2003 Retain for future use. NECESSRY TOOLS INSTLLTION 1. Turn off all

Más detalles

HD Media Tower / Tour Hi-Fi / Medios de Torre

HD Media Tower / Tour Hi-Fi / Medios de Torre English This page lists the contents included in the box. Please take time to identify the hardware as well as the individual components of the product. s you unpack and prepare for assembly, place the

Más detalles

Installation Guide. Wall Sconce

Installation Guide. Wall Sconce Installation Guide Wall Sconce K-10570 K-10571 K-10572 K-11365 K-11366 K-11367 M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M)

Más detalles

INTRODUCCIÓN 5 F E D 9. (On devices produced after 1/92) (En dispositivos fabricados. después de 1/92) (Sur dispositifs fabriqués après 1/92)

INTRODUCCIÓN 5 F E D 9. (On devices produced after 1/92) (En dispositivos fabricados. después de 1/92) (Sur dispositifs fabriqués après 1/92) Instruction Boletín de Directives Bulletin instrucciones d'utilisation AC Magnetic Contactors and Starters Contacteurs at démarreurs magnétiques CA Ref. / Réf. AS 00-0-0E Raleigh, NC, USA /0 Replaces /

Más detalles

WARNING AVERTISSEMENT ADVERTENCIA. Selecting Disney characters Sélection des personnages Disney Seleccionando caracteres Disney

WARNING AVERTISSEMENT ADVERTENCIA. Selecting Disney characters Sélection des personnages Disney Seleccionando caracteres Disney WARNING AVERTISSEMENT ADVERTENCIA The embroidery patterns which are pre-programmed into this sewing machine are for personal, private use only. Any commercial or business use is strictly forbidden by copyright

Más detalles

Introduction Introducción Introduction

Introduction Introducción Introduction Instruction Bulletin Boletín de instrucciones Directives d'utilisation 45123-930-01 Rev. 01, 08/2013 Replaces / Reemplaza / Remplace 45123-930-01C, 04/2011 I-Line II Busway Vertical Spring Hanger Soporte

Más detalles

ELIMINATOR FOUNDATION VENT FAN

ELIMINATOR FOUNDATION VENT FAN ELIMINATOR FOUNDATION VENT FAN Model: EL-1 and EL-1R This product is designed for ventilating or circulating air through crawl spaces of homes. By maintaining constant air flow through the crawl space,

Más detalles

Sistemas de protección contra fallas a tierra del equipo

Sistemas de protección contra fallas a tierra del equipo Instruction ulletin oletín de instrucciones Directives d'utilisation 48049-222-04 04/2008 Cedar Rapids, I, US ECN 675D Replaces / Reemplaza / Remplace 48049-222-03 12/2002 Neutral Current Transformers

Más detalles

Process Control Work Instructions Control de Procesos Instrucciones de Trabajo. for / para

Process Control Work Instructions Control de Procesos Instrucciones de Trabajo. for / para Process Control Work Instructions Control de Procesos Instrucciones de Trabajo for / para 629096898 VFCB Kit Relay Cable Harness Assy Ensamblar el Kit del Arnés de Cables del Relevador Publication Number:

Más detalles

Installation Instructions Instrucciones para la instalacion Guide d'installation

Installation Instructions Instrucciones para la instalacion Guide d'installation Deep Wall Extension Kit For 3/4 Volume Control Valve Installation Instructions Instrucciones de instalación del conjunto de extensión mural para válvula de control del volumen de 3/4" IInstructions d installation

Más detalles

Current and Voltage Transformers Transformadores de corriente y tensión Transformateurs de courant et de tension

Current and Voltage Transformers Transformadores de corriente y tensión Transformateurs de courant et de tension Instruction Bulletin Boletín de instrucciones Directives d'utilisation 02/2005 Huntington, IN USA Current and Voltage Transformers Transformateurs de courant et de tension Retain for future use. / Conservar

Más detalles

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS 36" WIDE 2 - DRAWER LATERAL FILE AIR? NEED HELP? Call 1 800 950 4782 www.bushbusinessfurniture.com Part Number Lot Code # Keep manual for future reference. IMPORTANT SAFETY INFORMATION

Más detalles

INSTRUCTION MANUAL Smart Security Light

INSTRUCTION MANUAL Smart Security Light SPL06-07A1W1-BKT-K1 INSTRUCTION MANUAL Smart Security Light Questions, problems, or missing parts? Before returning to the store, call MAXIMUS customer service at 1-866-897-2098, Monday Friday, 9:30am

Más detalles

MODEL WC53918 A175066

MODEL WC53918 A175066 MODEL WC53918 A175066 IMPORTANT SAFETY INFORMATION WARNING THIS PRODUCT IS DESIGNED AND INTENDED FOR USE WITH COMPUTER, FAX, AND PRINTER EQUIPMENT ONLY. IMPROPER LOADING WITH TELEVISION OR OTHER HEAVY

Más detalles

T87 Range Stops INSTALLATION APPLICATION INSTALLATION INSTRUCTIONS EFS

T87 Range Stops INSTALLATION APPLICATION INSTALLATION INSTRUCTIONS EFS T87 Range Stops APPLICATION Use the 0144-001 range stops with the T87K, N thermostats to limit the minimum and maximum temperature settings. The 0144-001 contains two range stop scales and two #2-28 x

Más detalles

INTRODUCCION. Este boletín incluye instrucciones de montaje, modificación y solicitud de piezas.

INTRODUCCION. Este boletín incluye instrucciones de montaje, modificación y solicitud de piezas. Instruction Boletín de Directives Bulletin instrucciones d'utilisation Ref./réf. 305AS 30072-03-0E Raleigh, NC, USA 2/02 Replaces / Reemplaza / Remplace 30072-03-0D 3/00 AC Magnetic Contactors and Starters

Más detalles

BASE & WALL EASY REACH CABINET 170º Hinge Replacement

BASE & WALL EASY REACH CABINET 170º Hinge Replacement These instructions should only be printed using Adobe Acrobat and should not be faxed or reproduced on a digital copier. American Woodmark Corporation provides these instructions on an AS IS basis and

Más detalles

1-800-295-5510 uline.com TECHNICAL DATA MODEL H-2051. Alkaline MN21 12V. (1 Second) Button Life Approx. 100,000 Push Button Presses 0.125 lbs. (2 oz.

1-800-295-5510 uline.com TECHNICAL DATA MODEL H-2051. Alkaline MN21 12V. (1 Second) Button Life Approx. 100,000 Push Button Presses 0.125 lbs. (2 oz. π H-2051 TAKE-A-NUMBER SYSTEM WIRELESS REMOTE uline.com Para Español, vea páginas 3-4. Pour le français, consulter les pages 5-6. TECHNICAL DATA MODEL H-2051 Frequency RF Power Output 433.92 MHz (+/ Max.

Más detalles

BlancoWhite D1 / D2 Ceiling Antoni Arola

BlancoWhite D1 / D2 Ceiling Antoni Arola Part 1 BlancoWhite D1 / D2 Ceiling Antoni Arola Lámpara de suspensión/ Hanging lamp/ Lampe à suspension x2 x2 CARACTERÍSTICAS TÉCNICAS/ TECHNICAL CHARACTERISTICS/ CARACTÉRISTIQUES TECHNIQUES Peso/ Weight/

Más detalles

Push Pull Installation Procedure

Push Pull Installation Procedure Push Pull Installation Procedure IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING Before installing this product, read and follow all warning notices and instructions

Más detalles

Masterpact NW 1000-4000 A DC Circuit Breaker Installation Tested to UL489 Supplement SC

Masterpact NW 1000-4000 A DC Circuit Breaker Installation Tested to UL489 Supplement SC 300 V MX Load/Carga/ Charge 300 V MX Masterpact NW 1000-4000 DC Circuit Breaker Installation Tested to UL489 Supplement SC Interruptor de potencia Masterpact NW de c.d., de 1 000 a 4 000 Probado de acuerdo

Más detalles

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module

FlexCage. User Manual MB975SP-B. 5 HDD Slots in 3 Device Bay. Tray-Less SATA Backplane Module FlexCage MB975SP-B 5 HDD Slots in 3 Device Bay Tray-Less SATA Backplane Module User Manual English Package Contents Front Panel Information HDD3 POWER BUTTON POWER / ACCESS LED INDICATOR HDD2 POWER BUTTON

Más detalles