IMPORTANT! Please Read Before Starting



Documentos relacionados
INSTALLATION INSTRUCTIONS

DECLARACION DE CONFORMIDAD DECLARATION OF CONFORMITY

MODEL: / MODELO: COMPUTER DESK ESCRITORIO DE COMPUTADORA

T R A N S TECHNICAL SPECIFICATIONS:

INSTALLATION INSTRUCTIONS SLM14 SLM22 SLM24 SLM- LED SLIM PANEL

Installation Guide. Green momit

Process Control Work Instructions Control de Procesos Instrucciones de Trabajo. for / para

INSTALLATION INSTRUCTIONS

Low Ambient Conversion For LG Single and Flex Multi Inverters

Como desempacar el Time Attendant Además de ésta guía, el empaque debe incluír lo siguiente: Time Attendant Quick Install Reference Guide

Flashcards Series 3 El Aeropuerto

Video Server. Quick Installation Guide. English, Español

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual DECLUTCHABLE WORM GEAR

INSTALLATION INSTRUCTION Vogue WS-3120

ENKVM-USBB. 2-Port USB KVM switch with Easy Switch and Cable. User Guide

INSTRUCTION MANUAL Smart Security Light

Steps to Understand Your Child s Behavior. Customizing the Flyer

ROCK N STEREO SOUND DESK

IE12_ CONSOLIDACIÓN Y DESARROLLO DE NUEVAS TÉCNICAS DE EVALUACIÓN INTENSIVAS ON-LINE YA IMPLEMENTADAS POR EL GIE E4

Save Money 2-up Single Doorhanger Set OH payday advance edition, 4 different doorhangers, Spanish

ASSEMBLY DRAWING / SPARE PARTS

Extension Cords Extensiones Eléctricas We light your world

HD Media Tower / Tour Hi-Fi / Medios de Torre

Agustiniano Ciudad Salitre School Computer Science Support Guide Second grade First term

Installation Guide C. Lavatory Drains

INSTALLATION INSTRUCTIONS

FCC Information : Warning: RF warning statement:

Cables monopolares media tensión aislados 90 ºC Monopolar insulated medium voltage cables 90 ºC

INSTALLATION GUIDE. AXIS T92A10 Protective Housing ENGLISH ESPAÑOL

BAI-220 AURICULAR INALÁMBRICO

S4 / S8 SIVACON. English. Español

CORTE Y PERFORACIÓN CUTTING AND DRILLING DÉCOUPAGE ET PERÇAGE

Wall Mounted Range Hood System

Quick Installation Guide TU2-DVIV H/W: V1.0R

1. Título: 2. Objetivos: 3. Contenidos de la propuesta: 4. Relación con los temas transversales: 5. Sesiones de trabajo: Preventing back injuires.

MANUAL DE INSTRUCCIONES INSTRUCTION MANUAL

Schindler 7000 Planning parameters of high-rise elevators.

2008 Series Hemodialysis Machine Operator s Manuals Addendum for Concentrate Connection

Guía de instalación rápida TFM-561U

Puede pagar facturas y gastos periódicos como el alquiler, el gas, la electricidad, el agua y el teléfono y también otros gastos del hogar.

SET CAR 20. User Manual/Manual de Uso. Rev

RocketBox AVISO IMPORTANTE ROCKETBOX PRO (1X) KEY (2X) CLÉ (X 2) LLAVES (2X) Part # Rev.C C-1/13

Matemáticas Muestra Cuadernillo de Examen

Table of Contents. Español Antes de iniciar Cómo conectar Cómo utilizar el conmutador... Troubleshooting... Version

π H-2561 Parts Assembly uline.com Tools needed H-2562 rectangular picnic table

In the following you see an example of a SPAC calculation run. BKtel systems Seite 1/8

Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY Phone (516) Fax (516)

M DJ SERIES. User Manual/Manual de Uso

Door Stop Kit, 316 SS Compas de porte, 316 SS Tope para puerta, 316 SS

Sistema de retención para mangueras de presión

Guía de instalación rápida TEG-160WS TEG-240WS

LAB 2: Circuitos de Corriente Directa (DC) PARTE I OBJECTIVES

Type KUL. Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation

24-Port 10/100Mbps Web Smart PoE Switch with 4 Gigabit Ports and 2 Mini-GBIC Slots TPE-224WS


SYSTEM INSTALLATION MANUAL MANUAL DE INSTALACIÓN

ARTICULO: Indicador entrada programable Multi input indicator

INSTALLATION INSTRUCTION LED Pendant PD-33718

Sierra Security System

SFD-200-N-B DESPERTADOR-PROYECTOR-CON VOZ. Manual de instrucciones

Specifications, Installation, and Operating Instructions GrowerSELECT 230 VAC Replacement Feed Sensor With Heating Element HS09

SIGUIENDO LOS REQUISITOS ESTABLECIDOS EN LA NORMA ISO Y CONOCIENDO LAS CARACTERISTICAS DE LA EMPRESA CARTONAJES MIGUEL Y MATEO EL ALUMNO DEBERA

GUÍA DE USUARIO PC Bienvenidos al mundo Perfect Choice. Antes de comenzar a usar el producto es importante que leas esta guía.

FIRE RED FUZZ. Bill Of Materials

Flashcards Series 4 El Hotel

THERMAL SWITCH AND SOLENOID VALVE INSTALLATION INSTRUCTIONS INSTRUCCIONES PARA LA INSTALACIÓN DE LA VÁLVULA SOLENOIDE Y DEL INTERRUPTOR TÉRMICO

MODEL: N / MODELO: N GAZEBO / GAZEBO

UNIDADES FANCOIL UNIVERSALES

Model/Modelo: SR42UBEVS

AT07. Board for Arduino UNO with terminal block placa para Arduino UNO con bornes Plaque pour ARDUINO UNO avec borniers pour CI

The Bonded Flange Center Drain Series are intended for use with the following waterproofing methods:

INSTRUCCIONES PARA ENVIAR SU PELICULA PARA LA VIDEOLIBRERIA

RTA-B002 DIMENSIONS MAXIMUM WEIGHT CAPACITIES. Highest position. Lowest position. Product Size: 22"W x 16"D x 30.5~46.5"H

BUILT-IN TRIM KIT INSTALLATION INSTRUCTION

LOW SPEED RIGHT ANGLE CUT-OFF TOOL

ENGLISH FRANÇAIS ESPAÑOL

Lump Sum Final Check Contribution to Deferred Compensation

CONTROLADORA PARA PIXELS CONPIX

JOHN LOUIS HOME STANDARD CLOSET SYSTEM

MANUAL DE INSTRUCCIONES PARRILLA BARBACOA (18 ) ED-4047BQ

Sistema de Luminarias Tecnológica - Verde - Eficiente

Effective 7/15 CAUTION ADVERTENCIA DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED.

IntesisBox PA-RC2-xxx-1 Panasonic compatibilities

EP-2906 Manual de instalación

MODEL: F / MODELO: F END TABLE WITH MEDIA STAND & MAGAZINE HOLDER MESA RINCONERA CON ESTANTE & REVISTERO

Instruction Bulletin. Power Supply. for use with POWERLINK G3 systems para utilizarse en los sistemas POWERLINK G3 (instructionnes en español: page 9)

Product / Producto: SPIDER ROBOT KIT / KIT DE ARAÑA CON CONTROL REMOTO Model / Modelo: K-665 Brand / Marca: Steren

Quick start guide.

INSTALLATION INSTRUCTIONS ECLIPSE FUEL DOOR PART # MZ313512


PREPARING FOR INSTALLATION ANTES DE LA INSTALACIÓN

K and M class flexible cables

Conditioning Exercises: Standing

uline.com. Phillips Screwdriver Mini Flathead Screwdriver Electric Drill 5/16" Drill Bit PARTS. Flat Display Wall Mount Bracket x 1

INSTALLATION INSTRUCTION LED Pendant PD-35603

With Flange: 1/2" Copper pipe stub-out length from finished wall surface

Specification Chart Tableau des spécifications Cuadro de especificaciones GASOLINE ENGINE (MOTEUR À ESSENCE) (MOTOR DE GASOLINA)

TELEVISOR A COLORES MANUAL DE SERVICIO MODELO : CP-29C40P. ATENCIÓN Antes de dar servicio al chasis, lea las PRECAUCIONES DE SEGURIDAD en este manual.

Nueva confirmación de pedido de compra con cambios: proveedor ES

Transcripción:

IMPORTANT! Please Read Before Starting This air conditioner must be installed by the sales dealer or installer This information is provided for use only by authorized persons For safe installation and trouble-free operation you must: Carefully read this instruction booklet before beginning Follow each installation or repair step exactly as shown This air conditioner shall be installed in accordance with National Wiring Regulations Pay close attention to all warning and caution notices given in this manual WARNING CAUTION This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage If Necessary Get Help These instructions are all you need for most installation sites and maintenance conditions If you require help for a special problem contact our sales/service outlet or your certified dealer for additional instructions In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service including failure to follow the instructions in this document SPECIAL PRECAUTIONS WARNING When Wiring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH ONLY A QUALIFIED EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked Highly dangerous electrical voltages are used in this system Carefully refer to the wiring diagram and these instructions when wiring Improper connections and inadequate grounding can cause accidental injury or death Connect all wiring tightly Loose wiring may cause overheating at connection points and a possible fire hazard Provide a power outlet to be used exclusively for each unit Provide a power outlet exclusively for each unit and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing Select an installation location which is rigid and strong enough to support or hold the unit and select a location for easy maintenance In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to walls and floors Keep the fire alarm and the air outlet at least CAUTION 15 m away from the unit In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid level foundation for the outdoor unit This prevents water damage and abnormal vibration In an Area with High Winds Securely anchor the outdoor unit down with bolts and a metal frame Provide a suitable air baffle In a Snowy Area (for Heat Pump-type Systems) Install the outdoor unit on a raised platform that is higher than drifting snow Provide snow vents At least 25 m Indoor unit of this room air conditioner shall be installed in a height of at least 25 m In laundry rooms Do not install in laundry rooms Indoor unit is not drip proof When Connecting Refrigerant Tubing WARNING When performing piping work do not mix air except for specified refrigerant (R410A) in refrigeration cycle It causes capacity down and risk of explosion and injury due to high tension inside the refrigerant cycle Refrigerant gas leakage may cause fire Ventilate the room well in the event that is refrigerant gas leaks during the installation Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas Keep all tubing runs as short as possible Use the flare method for connecting tubing Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them then tighten the nut with a torque wrench for a leak-free connection Check carefully for leaks before starting the test run Do not leak refrigerant while piping work for an installation or re-installation and while repairing refrigeration parts Handle liquid refrigerant carefully as it may cause frostbite 2

When Servicing Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning WARNING In case of malfunction of this appliance do not repair by yourself Contact the sales dealer or service dealer for repair CAUTION Do not touch the air inlet or the sharp aluminum fins of the outdoor unit You may get injured Ventilate any enclosed areas when installing or testing the refrigeration system Escaped refrigerant gas on contact with fire or heat can produce dangerously toxic gas Confirm after installation that no refrigerant gas is leaking If the gas comes in contact with a burning stove gas water heater electric room heater or other heat source it can cause the generation of poisonous gas Others NOTICE CAUTION Do not touch the air inlet or the sharp aluminum fins of the outdoor unit You may get injured Do not sit or step on the unit you may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The English text is the original instructions Other languages are translations of the original instructions E PORTUGUÊS ENGLISH 3

Page IMPORTANT 2 Please Read Before Starting 7 HOW TO INSTALL WIRELESS REMOTE CONTROLLER RECEIVER 24 1 GENERAL 5 NOTE 1-1 Tools Required for Installation (not supplied) Refer to the Operating Instructions attached to the optional 1-2 Accessories Supplied with Unit Wireless Remote Controller Receiver 1-3 Type of Copper Tube and Insulation Material 1-4 Additional Materials Required for Installation 8 APPENDIX 24 2 SELECTING THE INSTALLATION SITE 6 2-1 Indoor Unit Troubleshooting Tips for Energy Saving 3 SELECTING THE LOCATION FOR THE INDOOR UNIT 7 3-1 Required Minimum Space for Installation and Service 3-2 Suspending the Indoor Unit 3-3 Installing the Drain Pipe 3-4 Connecting Duct to Indoor Unit 3-5 External Static Pressure Setting for Dc Fan Motor Model 3-6 External Static Pressure Setting for AC Fan Motor Model 4 ELECTRICAL WIRING 18 4-1 General Precautions on Wiring 4-2 Recommended Wire Length and Wire Diameter for Power Supply System 4-3 Wiring System Diagrams 5 HOW TO PROCESS TUBING 22 5-1 Connecting the Refrigerant Tubing 5-2 Connecting Tubing Between Indoor and Outdoor Units 5-3 Insulating the Refrigerant Tubing 5-4 Taping the Tubes 5-5 Finishing the Installation 6 HOW TO INSTALL THE TIMER REMOTE CONTROLLER (OPTIONAL PART) 24 NOTE Refer to the Operating Instructions attached to the optional Timer Remote Control Unit 4

1 GENERAL This booklet briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning 1-1 Tools Required for Installation (not supplied) 1 Flathead screwdriver 2 Phillips head screwdriver 3 Knife or wire stripper 4 Tape measure 5 Carpenter s level 6 Sabre saw or key hole saw 7 Hacksaw 8 Core bits 9 Hammer 10 Drill 11 Tube cutter 12 Tube flaring tool 13 Torque wrench 14 Adjustable wrench 15 Reamer (for deburring) 1-2 Accessories Supplied with Unit See Table 1-1 Table Type 1-1 Ducted 1-3 Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source you will need: 1 Deoxidized annealed copper tube for refrigerant tubing 2 Foamed polyethylene insulation for copper tubes as required to precise length of tubing Wall thickness of the insulation should be not less than 8 mm 3 Use insulated copper wire for fi eld wiring Wire size varies with the total length of wiring Refer to 4 ELECTRICAL WIRING for details CAUTION Check local electrical codes and regulations before obtaining wire Also check any specified instructions or limitations 1-4 Additional Materials Required for Installation 1 Refrigeration (armored) tape 2 Insulated staples or clamps for connecting wire (See your local codes) 3 Putty 4 Refrigeration tubing lubricant 5 Clamps or saddles to secure refrigerant tubing 6 Scale for weighing Table 1-1 (Ducted) Part Name Figure Q ty Remarks Washer 8 For suspending indoor unit from ceiling Flare insulator 2 For gas and liquid tubes Hose band 5 For securing drain hose Foam drain socket Drain hose 1 Flange 2 Screw 4 Use M10 for suspension bolts Suspension bolts and nuts are fi eld supply 1 For drain hole (another side of drain hose) For inlet duct installation E PORTUGUÊS ENGLISH 5

25cm 2 SELECTING THE INSTALLATION SITE 2-1 Indoor Unit AVOID: areas where leakage of flammable gas may be expected places where large amounts of oil mist exist direct sunlight locations near heat sources which may affect the performance of the unit locations where external air may enter the room directly This may cause condensation on the air discharge ports causing them to spray or drip water locations where the remote controller will be splashed with water or affected by dampness or humidity DO: installing the remote controller behind curtains or furniture locations where high-frequency emissions are generated select an appropriate position from which every corner of the room can be uniformly cooled select a location where the ceiling is strong enough to support the weight of the unit select a location where tubing and drain pipe have the shortest run to the outdoor unit allow room for operation and maintenance as well as unrestricted air fl ow around the unit install the unit within the maximum elevation difference above or below the outdoor unit and within a total tubing length (L) from the outdoor unit as detailed in the installation manual packed with the outdoor unit allow room for mounting the remote controller about 1m off the floor in an area that is not in direct sunlight or in the flow of cool air from the indoor unit 25cm 25cm Fig 2-1 6

3 SELECTING THE LOCATION FOR THE INDOOR UNIT 3-1 Required Minimum Space for Installation and Service Provide a check port on the piping side ceiling for repair and maintenance Install the indoor unit once the following conditions are satisfied and after receiving the customer approval 1 The indoor unit must be within a maintenance space 2 The indoor unit must be free from any obstacles in path of the air inlet and outlet and must allow spreading of air throughout the room ENGLISH Top view (Unit:mm) Inspection hole (600 x 600) Control box Front view 600 <Front> 1000 600 Above 250cm If the height from the floor to ceiling exceeds three meters air flow distribution deteriorates and the effect is decreased Fig3-1 POSITION OF SUPENSION BOLT A B Apply a joint-canvas between the unit and duct to absorb unnecessary vibration Install the unit leaning to a drainage hole side as a figure for easy water drainage D E PORTUGUÊS (Unit:mm) C E TYPE A B C D E S-36PN1E5A S-45PN1E5A S-50PN1E5A 840 780 523 64 650 S-60PN1E5A S-71PN1E5A 1060 1000 523 64 650 S-100PN1E5A S-125PN1E5A S-140PN1E5A 1260 1200 523 64 650 Absorber 1~3mm Drainage hole Caution Remove the absorber at air return hole before installation Fig3-11 7

250 80 100 55 20 45 55 65 740 650 (P65 x 10) Air Flo w 22 ø45 24 ø45 65 585 (P65 x 9) 670 840 Air Flo w 900 780 D r a i n pip e c onnectio n 64 523 S-50PN1E5A Outside Dimensions MODEL NO S-45PN1E5A S-36PN1E5A UNIT : m m 31 161 58 48 65 48 30 134 650 30 23 31 187 32 6 Control box 1 5 Hangger 4 4 Dutch connection 2 3 Drain pipe connection 2 Female screw PT1" 2 Pipe connection (liquid) 1 OD ø635 Flared 1 Pipe connection (gas) 1 OD ø127 Flared No NAME Q TY NOTE 8

Air Flo w Air F l o w D r ain pip e connectio n E PORTUGUÊS No NAME Q TY NOTE 1 Pipe connection (gas) 1 OD ø1588 Flared 2 Pipe connection (liquid) 1 OD ø952 Flared 3 Drain pipe connection 2 Female screw PT1" 4 Dutch connection 2 5 Hangger 4 6 Control box 1 UNIT : m m Outside Dimensions MODEL NO S-60PN1E5A S-71PN1E5A ENGLISH 64 523 23 20 575 55 100 960 845 (P65 x 13) 65 28 ø45 30 ø45 65 780 (P65 x 12) 55 890 1060 1120 1000 31 187 32 23 134 80 250 30 134 650 30 48 65 48 31 161 58 9

250 80 575 100 60 20 65 65 1260 1160 1040 (P65 x 16) 44 ø45 46 ø45 975 (P65 x 15) 1090 O U TLE T 1320 1200 D r a i n pip e connect i o n 64 523 30 650 30 31 31 No NAME Q TY NOTE 1 Pipe connection (gas) 1 OD ø1588 Flared 2 Pipe connection (liquid) 1 OD ø952 Flared 3 Drain pipe connection 2 Female screw PT1" 4 Dutch connection 2 5 Hangger 4 6 Control box 1 187 32 48 65 48 161 58 UNIT : m m Outside Dimensions MODEL NO S-100PN1E5A S-125PN1E5A S-140PN1E5A Unit:mm Fig3-2 10

3-2 Suspending the Indoor Unit Depending on the ceiling type: Insert suspension bolts (Fig 3-3) or Use existing ceiling supports or construct a suitable support (Fig 3-4) Suspension bolt Hexagonal nut Double nuts ENGLISH Hole-in-anchor Hole-in-plug Concrete Insert Fig3-6 This shows an example of installation Air outlet duct Suspension bolt Bolt anchor Suspension bolt (M10 or 3/8") (field supply) Ceiling tiles Ceiling support Fig3-3 Air-outlet grille Indoor unit Ceiling material Fig3-7 WARNING Fig3-4 It is important that you use extreme care in supporting the indoor unit inside the ceiling Ensure that the ceiling is strong enough to support the weight of the unit Before hanging the unit test the strength of each attached suspension bolt (1) When placing the unit inside the ceiling determine the pitch of the suspension bolts referring to the dimensional data as shown in Fig 3-1 and Table 3-2 Tubing must be laid and connected inside the ceiling when suspending the unit If the ceiling is already constructed lay the tubing into position for connection to the unit before placing the unit inside the ceiling (2) Screw in the suspension bolts allowing them to protrude from the ceiling (Fig 3-3) (Cut the ceiling material if necessary) (3) Thread the 3 hexagonal nuts and 2 washers (fi eld supply) onto each of the 4 suspension bolts (Figs 3-5 and 3-6) Use 1 nut and 1 washer for the upper part and 2 nuts and 1 washer for the lower part so that the unit will not fall off the suspension lugs Suspension bolt E PORTUGUÊS Nuts and washers (use for upper and lower) Suspension lug Double nuts Notch Fig3-5 11

3-3 Installing the Drain Pipe (1) Prepare standard hard PVC pipe (OD 32 mm) for the drain and use the supplied hose band to prevent water leaks The PVC pipe must be purchased separately CAUTION Do not use adhesive tape at the drain connection port on the indoor unit Insert the drain pipe until it contacts the socket and then secure it tightly with the hose band Do not use the supplied drain hose bent at a 90 angle (The maximum permissible bend is 45 ) Tighten the hose clamps so their locking nuts face upward (Fig 3-8) Hose clip (Accessory) Heat insulator (Local supply) (The thickness must be at least 8 mm) Flexible hose with heat insulator (Accessory) To be glued It may be required to take off this part for checking or servicing the drain up motor Please do not glue PVC pipe (OD ø32) (Local supply) Make sure that there is no clearance here Fig3-8 (2) After connecting the drain pipe securely wrap the supplied packing and drain pipe insulator around the pipe then secure it with the vinyl clamps (Fig 3-9) Drainage hole Thermal insulator (Accessories) Hose clip (Accessories) Do not install the pipe with an upward gradient from the connection port This will cause the drain water to fl ow backward and leak when the unit is not operating (Fig 3-12) Prohibited Upward gradient Fig3-11 Fig3-12 Do not apply force to the piping on the unit side when connecting the drain pipe The pipe should not be allowed to hang unsupported from its connection to the unit Fasten the pipe to a wall frame or other support as close to the unit as possible (Fig 3-13) Support pieces Fig3-13 Drain insulator (supplied) Vinyl clamps (field supply) Fig3-9 3-4 Connecting Duct to indoor Unit (1) Install the duct (local supply) for the Dimension of the installation hole Use M5 self-tapp Screws for installation see the Figure 3-2 (2) The duct connection of the air outlet needs thermal insulation NOTE Make sure the drain pipe has a downward gradient (1/100 or more) and that there are no water traps Air outlet Thermal insulator (Local arrangement) CAUTION Do not install an air bleeder as this may cause water to spray from the drain pipe outlet (Fig 3-10) Prohibited Air bleeder NOTE Select an air-intake grille with a filter at a local shop Fig3-14 To get clean air and to extend the service life of the air conditioner an air filter must be installed in the air intake For installation and cleaning the air filter consult your dealer or service center Fig3-10 12

3-5 External Static Pressure Setting for Dc Fan Motor Model Choose one of the following methods from a b c or d as shown in the flow chart (within the dotted lines) and then make the setting accordingly a No setting modification : Use-as-is at shipment (there are cases in which the setting may differ from the shipment setting when reset after once setting the external static pressure) b Manual setting (set with the PC board) : For high static pressure Switching method with the short-circuit connector c Manual setting (set with the wired remote controller) : Low static pressure ~ high static pressure d Auto airflow volume setting (set on the wired remote controller) : Air outlet volume is automatically adjusted to the rated airflow volume with the auto airflow control drive Flow of External Static Pressure ENGLISH Start external static pressure setting Finish the ducting and electrical wiring and prepare it for use (Note (1)) External static pressure should be set during initial operations after installation (before the cooling and heating test run) When operating with group control (connecting multiple indoor units with one wired remote controller) make the low silhouette ducted type to the main unit Line 3 (set at shipment) on the PQ diagram designed and installed No Yes Lines e and d settings (high static pressure) on the PQ diagram required No Yes a No setting modification No b Manual setting (set with the PC board) TP3 or TP1 short-circuit Refer to section 3-6-1 How to Set on PC Board Timer remote controller available Yes No c Manual setting Item code b0 : 0~15 setting (*Note (3)) (* Note (4)) Refer to section 3-6-2 Operation of Timer Remote Controller (CZ-RTC2) Set the rated airflow volume with the exception of lines e d and 3 Yes d Auto airflow volume setting (* Note (4)) Item code b0 : -2 setting Refer to section 3-6-2 Operation of Timer Remote Controller (CZ-RTC2) E PORTUGUÊS Operation checks for external static pressure settings (*Note (2)) Refer to section 3-6-2 Operation of Timer Remote Controller (CZ-RTC2) Check if the setting is within the range of use on the PQ diagram If out of range adjust until it becomes within the range of use This can be omitted if deemed unnecessary in the event of the same installation/set-up being available Test operation display will disappear (*Note (6)) External static pressure setting completed Auto airflow volume control operations (*Note (5)) Refer to section 3-6-2 Operation of Timer Remote Controller (CZ-RTC2) NOTE (1) Check the following items before performing the setting-check operations or auto airfl ow volume operations 1) Check to make sure that the electrical wiring and ducting have been completed Activate the stand-by mode In particular make sure that the closed damper located in the middle of the duct is open if installed Also make sure that air fi lters have been installed inside the air inlet duct Check to make sure air is not leaking from the joints 2) If multiple air outlets and air inlets are included adjust the airfl ow volume ratio of all of them until they meet the design airfl ow ratio 3) Make sure the address setting has been completed (2) The operation check will be completed in approximately three minutes if the settings have been made correctly The settings will be modifi ed if they are out of the range of use (max 30 mins) If this is not completed within 31 minutes check whether the air speed is set to H or not 13

(3) Refer to Table 3-4 and Fig 3-18 for details on the relationship between the value of item code b0 and the external static pressure (4) When set in group control (connecting multiple indoor units with one wired remote controller) set each indoor unit to item code b0 When amending the setting after selecting [ b Manual setting] (due to airfl ow path changes etc) it is necessary to cancel [b Manual setting] (disconnect short-circuit connector) When [b Manual setting] has not been cancelled [c Manual setting] and [d Auto airfl ow volume setting] will be activated if selected but [b Manual setting] takes precedence when the power is switched back on after power outages etc (5) If this is not completed within 8 minutes check the drive mode air speed and air inlet temperature (6) When set in group control (connecting multiple indoor units with one wired remote controller) the test run operations display will disappear once the external static pressure setting check or auto airfl ow volume control operation check have been completed for the main unit Decisions on sub-unit complete are not possible The test run operation display will disappear after one hour even if the external status pressure setting check or auto airfl ow volume control operation check have not been completed CAUTION Be sure to check that the external static pressure is within the range for use and then make the setting Failure to observe this may result in insufficient airflow or water leakages Refer to Fig 3-18 for the external static pressure setting range There are cases in which automatic variable dampers and other mounted items may trigger the P12 alarm on systems that modify the static pressure of outdoor units when the auto airflow volume control operations or setting check operations are carried out if high static pressure in the outdoor unit is lowered In this event lower the dampers etc so that the static pressure in the outdoor unit reaches its lowest level and then carry out the auto airflow volume control operations or setting check operations Be sure to set the [External Static Pressure Setting] once again after amending the airflow path for the duct or air outlet after setting the external static pressure Set the air inlet temperature within the range for use The auto airflow volume control will not function if the air inlet temperature is over 45 C or not in the fan mode 3-5-1 How to Set on PC Board Table 3-3 Selection of connected short-circuit pins 1 Turn off the power breaker to halt the supply of electricity to the PC board 2 Open the lid of electrical equipment box and check where the short-circuit pin on the indoor unit control PC board is located (Fig 3-17) 3 Short circuit the applicable short-circuit pin in accordance with the selected short-circuit pin connected (Table 3-3) External static pressure at the time of rated airflow volume Unusable line e line d Short-circuit pin TP6 (2P: white) TP3 (2P: yellow) TP1 (2P: red) White Yellow Red TP6 TP3 TP1 TP6 TP3 TP1 Indoor Unit control PC board Fig3-17 14

3-5-2 Operating the Timer Remote Controller (CZ-RTC2) Table 3-4 Setting the external static pressure 3-6-2-1 Setting Item Code Indoor unit Item code 1 Press and hold down the and buttons simultaneously for 4 or more seconds ( the Unit No Item Code and Detailed Data will blink on the remote controller s LCD display) 60 71 100 125 140 External static pressure of the rated air flow volume (Pa) b0 ENGLISH 2 The indoor unit numbers in the group control will be sequentially displayed whenever the Unit Select button is pressed Only the fan motor for the selected indoor unit will operate during this 3 Specify the item code by pressing the / buttons for the temperature setting buttons and confi rm the values ( set at shipment ) 4 Press the / buttons for the time to amend the values for the set data Refer to table 3-4 and Fig 3-18 and select a value between and Select if the auto airfl ow volume setting is activated according to Indoor Unit P-Q diagram No auto airflow volume setting Auto airflow volume setting 5 Press the button The display will stop blinking and remain illuminated 6 Press the button The fan motor will stop operating and the LCD display will return to the normal stop mode 3-5-2-2 Auto Airflow Volume Control Operations and External Static Pressure Setting-Check Operation 1 Press and hold down the button for 4 or more seconds will be displayed on the remote controller s LCD display 2 Press the button to commence the test run [Test Run] will be displayed on the remote controller s LCD display 3 Select the fan mode and set it to H by pressing the button CAUTION Auto airfl ow volume control operations and external static pressure setting-check operations will not be performed unless [H] has been selected for the fan mode 4 The fan motor will be activated and auto airfl ow volume control operations or external static pressure setting-check operations will commence The power of the airfl ow will change while these operations are in progress The external static pressure setting-check operations and auto airfl ow volume control operations will be completed in about 3 to 30 minutes The display will be extinguished from the remote controller s LCD display 1 6 5 1 4 * Failure to set this parameter may result in decreased airflow and condensation 2 3 3 5 2 E PORTUGUÊS 5 Press the button to halt the test run 1 15

Indoor Fan Performance Item code Tap 15 14 13 12 11 8 6 5 3 1 1-2 1-3 Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating H M L H H H M H H H H M H H M M M M H H L M M M H H M M H H L L L L L L M M M M H H L L L L L L M M H H Setting at shipment L L L L M M L L S-60PN1E5 S-71PN1E5 P-Q diagram S-125PN1E5 P-Q diagram Limit line External Static Pressure (Pa) External Static Pressure (Pa) Limit line Air Volume (m 3 /min) Air Volume (m 3 /min) S-100PN1E5 P-Q diagram S-140PN1E5 P-Q diagram External Static Pressure (Pa) Limit line External Static Pressure (Pa) Limit line Air Volume (m 3 /min) Air Volume (m 3 /min) Fig 3-18 16

3-6 External Static Pressure Setting for AC Fan Motor Model To apply to following models S-36PN1E5 S-45PN1E5 S-50PN1E5 ENGLISH There are two tap connector located in indoor unit control box can be selected The blue connector is standard tap use-as-is at shipment For high static pressure duct switch Fan Motor connector to plug in boost tap white connector to elevate air volume S-36PN1E5 P-Q CURVE external Static Pressure (Pa) 80 70 60 50 40 Lo 30 20 10 0 8 S-45PN1E5 S-50PN1E5 80 70 60 50 40 Lo 30 20 10 0 10 external Static Pressure (Pa) boost tap SHi standard tap Hi Me Air Volume (m 3 /min) 18 P-Q CURVE boost tap SHi standard tap Hi Me 20 Air Volume (m 3 /min) E PORTUGUÊS 17

4 ELECTRICAL WIRING 4-1 General Precautions on Wiring (1) Before wiring confi rm the rated voltage of the unit as shown on its nameplate then carry out the wiring closely following the wiring diagram (2) Provide a power outlet to be used exclusively for each unit and a circuit breaker for overcurrent protection should be provided in the exclusive line (3) To prevent possible hazards from insulation failure the unit must be grounded (4) Each wiring connection must be done in accordance with the wiring system diagram Wrong wiring may cause the unit to misoperate or become damaged (5) Do not allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan (6) Unauthorized changes in the internal wiring can be very dangerous The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes (7) Regulations on wire diameters differ from locality to locality For fi eld wiring rules please refer to your LOCAL ELECTRICAL CODES before beginning You must ensure that installation complies with all relevant rules and regulations (8) To prevent malfunction of the air conditioner caused by electrical noise care must be taken when wiring as follows: The remote control wiring and the inter-unit control wiring should be wired apart from the inter-unit power wiring Use shielded wires for inter-unit control wiring between units and ground the shield on both sides (9) If the power supply cord of this appliance is damaged it must be replaced by a repair shop designated by the manufacturer because special-purpose tools are required 4-2 Recommended Wire Length and Wire Diameter for Power Supply System Indoor unit Type (B) Power supply 25 mm 2 Time delay fuse or circuit capacity N1 SERIES Max 130 m 10-16 A Control wiring (C) Inter-unit (between outdoor and indoor units) control wiring (D) Remote control wiring (E) Control wiring for group control 075 mm 2 (AWG #18) Use shielded wiring* 075 mm 2 (AWG #18) 075 mm 2 (AWG #18) Max 1000 m Max 500 m Max 200 m (Total) NOTE * With ring-type wire terminal 18

4-3 Wiring System Diagrams Power supply 220/230/240V ~50Hz Indoor unit (No1) * 3-phase model connections Outdoor unit (3-phase) INV unit ENGLISH Remote controller Ground Ground Power supply 380 415 V 3 N~ 50Hz Ground Power supply 220/230/240V ~50Hz Remote controller Ground Indoor unit (No1) Ground * Single-phase model connections Outdoor unit (single-phase) INV unit Power supply 220 240 V ~50Hz Ground Fig 4-1 NOTE 6P terminal board (1) Refer to Section 4-2 Recommended Wire Length and Wire Diameter for Power Supply System for the explanation of A B C D and E in the above diagram (2) The basic connection diagram of the indoor unit shows the terminal boards so the terminal boards in your equipment may differ from the diagram (Fig 4-2) (3) Refrigerant Circuit (RC) address should be set before turning the power on (4) Regarding RC address setting refer to the installation instructions supplied with the remote controller unit (Optional) Auto address setting can be executed by remote controller automatically Refer to the installation instructions supplied with the remote controller unit (optional) R1 R2 U1 U2 L N Remote controller line Unit control wiring Power suppy Shielded wire ground N1 Type Earth Fig 4-2 E PORTUGUÊS 19

CAUTION (1) When linking the outdoor units in a network disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units (When shipping: In shorted condition) For a system without link (no wiring connection between outdoor units) do not remove the short plug (2) Do not install the inter-unit control wiring in a way that forms a loop (Fig 4-3) Outdoor unit Outdoor unit Outdoor unit Prohibited Prohibited Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit (3) Do not install inter-unit control wiring such as star branch wiring Star branch wiring causes mis-address setting (Fig 4-4) Fig 4-3 Outdoor unit NO Indoor unit Indoor unit Indoor unit Indoor unit Branch point (4) If branching the inter-unit control wiring the number of branch points should be 16 or fewer (Branches that are less than 1 m are not included in the total branch number) (Fig 4-5) Fig 4-4 Outdoor unit Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit Branch Point 16 or fewer Indoor unit Indoor unit Indoor unit Indoor unit more than 1 m more than 1 m Indoor unit less than 1 m Indoor unit (5) Use shielded wires for inter-unit control wiring (c) and ground the shield on both sides otherwise misoperation from noise may occur (Fig 4-6) Connect wiring as shown in Section 4-3 Wiring System Diagrams Ground Shielded wire Ground WARNING Fig 4-5 Loose wiring may cause the terminal to overheat or result in unit malfunction A fire hazard may also occur Therefore ensure that all wiring is tightly connected When connecting each power wire to the terminal follow the instructions on How to connect wiring to the terminal and fasten the wire securely with the terminal screw Fig 4-6 (6) Use the standard power supply cables for Europe (such as H05RN-F or H07RN-F which conform to CENELEC (HAR) rating specifications) or use the cables based on IEC standard (245 IEC57 245 IEC66) 20