FIRECLASS Panels Installation Notes - CPU801 Processor Board

Documentos relacionados
Cómo comprar productos de ServSafe International

Page English 2 Español 4 Update File Control Units with TFT screen

Asignar y seguir el progreso del curso en línea de Seguridad de los alimentos de ServSafe International

MMS. Operation. MMS Quick Setup Guide

Creating New Parent Accounts on SDUHSD Information Portal

Xfinity Prepaid. Roku setup guide

USER MANUAL LOGAN CAM VIEW FOR PC LOGAN CAM VIEW PARA PC English / Español

1. Conecte el transmisor FM al dispositivo encendedor del coche o a una fuente de alimentación.

Certificación Digital en PDF Signer Online. Digital Certification in PDF Signer Online.

Manual para Cambio de Apariencia en Acrobat Reader DC. Change of Appearance in Acrobat Reader DC

Ingreso a DatAcademy mediante Telefónica Accounts. Versiones: Español / Ingles Guía de usuario / User Guide

Manual para Cambio de Apariencia en Adobe Acrobat Pro. Change of Appearance in Adobe Acrobat Pro.

Online Registration Inscripción Electrónica

MANUAL EASYCHAIR. A) Ingresar su nombre de usuario y password, si ya tiene una cuenta registrada Ó

Bluebeam Digital Certification Manual

CESVA USB DRIVER. M_CUD_v0001_ _ESP_ENG

Go to: Select Tickets Festival Passes. Ir a la página:

In the following you see an example of a SPAC calculation run. BKtel systems Seite 1/8

SIHI México, S. de R.L. de C.V. Pricing Guide

Certificación Digital en DTE PDF Signer Online. Digital Certification in DTE PDF Signer Online

Creating your Single Sign-On Account for the PowerSchool Parent Portal

CONTROLADORA PARA PIXELS CONPIX

USER MANUAL VMS FOR PC VMS PARA PC English / Español

Paso 2: Descargar la app Wattio SmartHome Crear reglas en la app. Wattio SmartHo Guía rápida - Quick starting guide

Añadir para firmar digitalmente documentos EDE. Add digital signatures to EDE documents

WebForms con LeadTools

QUICK START GUIDE BLUESTICK. Portable Reader for Livestock. v. 2. Corporate Headquarters:

Manual de Exportación de Certificados Digitales

Georgetown ISD Nuevos Estudiantes de Inscripción en Línea. PRIMER PASO: Solicitud de cuenta de Inscripción de Nuevos Estudiantes

Guía de instalación rápida TU-S9

CONTROL DE ACCESO ACC4.NET

CONV-USB OPERATION MANUAL GUIDA UTENTE MANUAL DE INSTRUCCIONES OPTIKA MICROSCOPES - ITALY

Instalación X-Lite. Autor: Airsat 05-Abr-2010 Versión: 1.0

Clients. PPPoE Clients WINDOWS 7

USER MANUAL Setting up and using Presets in the PTZ Configuración y uso de Presets en la PTZ English / Español

Tips to Complete the USI International Student Application Consejos para completar la solicitud de admisión como estudiante internacional en USI

Pag.2 Italiano Configurazione minima PC per l utilizzo del software GIOTTO MobilCAD

Timulus. Setup Manual CLEARTON, LLC. The Smart Security Camera. Better Technology for Humanity

[RHSA-2018: ] Important: libvirt security update

Guía para la instalación de discos duro SATA y Configuración RAID

How to Get Started with FamilyID for Athletic Team Registration

School Preference through the Infinite Campus Parent Portal

QUICK GUIDE RECORD SETUP CONFIGURACIÓN DE GRABACIÓN English / Español

Upgrade de NX-OS y power-sequencer para equipos NEXUS 5020 Juan Olivares HTE, FTS.

GUÍA RÁPIDA QUICK GUIDE

. Guía de procedimientos del Portal de Licencias de Symantec

Microsoft Office Word

Agustiniano Ciudad Salitre School Computer Science Support Guide Second grade First term

NCTE 2018 Step by Step Registration Tutorial Teo.cr + Sched NCTE Proceso de Matrícula Paso a Paso Teo.cr + Sched

Cómo comprar en la tienda en línea de UDP y cómo inscribirse a los módulos UDP

1) Through the left navigation on the A Sweet Surprise mini- site. Launch A Sweet Surprise Inicia Una dulce sorpresa 2016

Nueva confirmación de pedido de compra con cambios: proveedor ES

Quick Installation Guide Internet Setup

Pantalla de navegación segura. Actualización del software de VesselView. Consulta automática por Wi-Fi. Uso de la microtarjeta SD

Parent Access Directions

Lecciónes para Transportistas

New Student/Parent Enrollment Instructions

NAVIGATOR NODE POE. Art-Net to DMX node USER MANUAL / MANUAL DE USUARIO

Actualización de los componentes del sistema en la serie AGI 300 SO principal SO de config. Bootloader

TomTom ecoplus. Update Tool

CENTRO DE BACHILLERATO TECNOLÓGICO INDUSTRIAL Y DE SERVICIOS #166 Pablo Torres Burgos

MANUAL HR RXUNICOM

Video Server. Quick Installation Guide. English, Español

Home Access Center Matriculación Electrónica Verificación Del Estudiante

QUICK GUIDE RECORD SETUP CONFIGURACIÓN DE GRABACIÓN English / Español

Do Now Question 1: Pregunta 1

GUIA PARA CARGAR UN TRABAJO EN LA PLATAFORMA WEB SILAE UPLOADING A PAPER ON THE SILAE WEB PLATFORM: A HOW-TO GUIDE

Los nombres originales de los territorios, sitios y accidentes geograficos de Colombia (Spanish Edition)

Utilidad de configuración Guía del usuario

Laboratorio 7.3.2: Demostración de la instalación de Windows XP

1 Página. Manual de TERMView. Menú de Inicio de Sesión

Creación de una cuenta Portal para Padres

Salaried/Exempt Time Reporting

Creating a Dynamic Section View of an Assembly By Ing. Jorge Garza Ulloa, MC

Software TRENDnetVIEW Pro. Guía de instalación rápida de TRENDnetVIEW Pro (1)

MANUAL DE INSTRUCCIONES TECLADO PARA TABLETA ACC-5188TKB

PARTE III. Instalación y Configuración De Cacti

REMEMBER YOU MUST READ YOUR ADMIN PACK Step 1: Place the following into the grey plastic envelope (see photo of grey envelope below):

Pasos Instalación de OnGuard (Versión beta 0.1)

Digitally Certifying Using Autodesk Design Review

1. Ensure your student s record is up-to-date in SchoolMax. It s important that we have accurate phone numbers and addresses on file.

Escuela Preparatoria Ixtlahuaco. Tema: plans and projects.

リセラードキュメント. Tabla de contenidos

Mil Y Una Noches, Las (Spanish Edition) By Anónimo READ ONLINE

[RHSA-2018: ] Important: kernel security update

Manual para Descompresión de Archivos. File Decompression Manual

MMS. Operation. Engine Start and Stop

Bluebeam Change Digital Certification Appearance Manual. Manual Cambio de Apariencia en Bluebeam Revu

Guía de instalación rápida TFM-561U

Do Now! Question 1: Pregunta 1

Installation Guide. Green momit

Zotero Quick Access Guide / Guía de acceso rápido para Zotero

TX MULTI MANUAL TX MULTI. Mando copiador multifrecuencia 1. PASOS PARA COPIAR UN MANDO CÓDIGO FIJO Y ROLLING ESTÁNDAR:

Diccionario De Uso Del Espanol / Dictionary Of The Use Of Spanish (Spanish Edition) By María Moliner

EP-2906 Manual de instalación

Mac Guía de procedimientos iniciales

Ayurveda: La Ciencia De Curarse Uno Mismo (Spanish Edition) By Vasant Dr. Lad READ ONLINE

Gestión De Servicios TI Basado En ITIL V3: Guia De Bolsillo (spanish Version) (ITSM Library) (Spanish Edition) By Ruby Tjassing READ ONLINE

Creando Cuentas Nuevas para Padres / Alumnos en el

Transcripción:

FIRECLASS Fire detection system FIRECLASS Fire detection system FIRECLASS Panels Installation Notes - Processor Board This leaflet provides step by step instructions on how to update the panel and transfer configuration to the panel. You need the firmware and site configuration to be available on a USB stick (drive). Create this using FIRECLASS Express, as described in the FIRECLASS Express help. Runtime Update Use this mode for updating a pre-configured panel. This mode could also be used for updating a remote panel on the network. Note Only a configuration update of a network panel is allowed. Only remote panels can be updated using this mode. 1 Insert the H3 link and USB drive while the panel is running and login at an appropriate level. 2 Select Main Menu 7 Service 9 - Panel Setup option. 3 Select the panel to update and press ENTER. 4 Select the project which the panel belongs to and press ENTER. Follow the instructions on the screen including confirming the update, removing the link and restarting the panel. Note The H3 link must be removed before restarting the panel. Failure to do so may boot the panel in Startup Mode. Startup Mode Use this mode for updating the node address of the panel and loading the menus in the local language. In order to use this mode you need to have created a USB drive with the Startup info for panel in FIRE- CLASS Express. (For details, refer to the FIRECLASS Express help file). 1 Ensure that the H3 link is fitted. Insert the USB drive into the board. Press the reset button on the CPU momentarily. 2 The panel will restart in Startup Mode. If the panel starts in normal mode please follow the instructions for Runtime Update. 3 Press passcode. Enter USER ID 01 and the PASSCODE that was used to create the Startup info for the USB drive. 4 Select 1-USB Download option. In the next display screen select the appropriate project on the drive. Press ENTER to select. 5 In the next screen select the appropriate panel. This will download the contents from the USB drive into the panel. It will contain firmware or configuration or both depending on the selection made within FIRECLASS Express. It is important to note the display messages and follow the prompts including removing links and the USB drive and restarting the panel. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland www.fireclass.net 120.515.288_FC-P--I, doc. version 1.0, 8. February 2016 Subject to change without notice. Fixing instructions Doc. version 1.0 1/4

FIRECLASS Fire detection system FIRECLASS Fire detection system Rescue Mode 1 Use this mode if the panel fails to boot and you have to rescue the panel by reloading its firmware. Note that using this mode will rewrite new firmware into the panel. Insert the USB drive containing the Startup info created using the FIRECLASS Express. 2 Insert both the X501(service mode) link and H3 link. 3 Press the reset button on the CPU momentarily. 4 The panel will now load the firmware from the USB drive into the panel and boot into Startup Mode. 5 Follow instructions from item 3 in the section headed Startup Mode to load a valid configuration. Transfer Configuration This operation requires a USB drive. This drive needs to be prepared using the transfer menu within FIRECLASS Express with the appropriate firmware and configuration files to be used to perform the update. For additional details on Firmware transfer, refer to the latest version of the FIRE- CLASS Express help file. 2/4 Fixing instructions Doc. version 1.0 Fixing instructions Doc. version 1.0 3/4

Sistema de detección de incendios FIRECLASS Sistema de detección de incendios FIRECLASS s de instalación para las centrales de incendios FIRECLASS - Placa base En este folleto se proporcionan las instrucciones, paso a paso, sobre cómo actualizar la central y la configuración de transferencia a la central. El firmware y la configuración del emplazamiento deben haberse guardado previamente en una memoria USB (unidad). Para ello, utilice FIRECLASS Express y siga las instrucciones de la ayuda de FIRECLASS Express. Actualización del tiempo de ejecución Utilice este modo para actualizar las centrales de incendios preconfiguradas. Este modo también puede utilizarse para actualizar una central de incendios remota de la red. Sólo se permite actualizar la configuración de la central de incendios de red. Con este modo solo se pueden actualizar las centrales de incendios remotas. 1 Inserte el enlace H3 y la memoria USB en la central de incendios encendida e inicie sesión con los derechos necesarios. 2 Seleccione el Menú principal 7 Servicio 9 - Config. central. 3 Seleccione la central de incendios que quiera actualizar y pulse ENTER. 4 Seleccione el proyecto al cual pertenece la central de incendios y pulse ENTER. Siga las instrucciones de la pantalla, incluido confirmar la actualización, extraer el enlace y reiniciar la central de incendios. El enlace H3 debe retirarse antes de reiniciar la central de incendios. Si no se hace, la central de incendios podría reiniciarse en Modo de arranque. Modo de arranque Utilice este modo para actualizar la dirección del nodo de la central de incendios y cargar los menús en el idioma local. Para poder utilizar este modo, primero debe haberse cargado la información de arranque para la central de incendios en una memoria USB utilizando FIRECLASS Express. (Para más detalles, consultar la ayuda de FIRECLASS Express). 1 Compruebe que el enlace H3 esté instalado. Inserte la memoria USB en la placa. Pulse brevemente el botón de reinicio de la CPU. 2 La central de incendios se reiniciará en el modo de arranque. Si la central de incendios se pone en marcha en el modo normal, siga las instrucciones de "Actualización del tiempo de ejecución". 3 Pulse la contraseña. Introduzca USER ID 01 y la CONTRASEÑA utilizada para crear la información de arranque en la memoria USB. 4 Seleccione la opción 1- Descarga USB. En la pantalla siguiente, seleccione el proyecto correspondiente en la memoria. Pulse ENTER para confirmar la selección. 5 En la pantalla siguiente, seleccione la central de incendios pertinente. El contenido de la memoria USB se descargará a la central de incendios. Este contenido incluirá el firmware, la configuración o ambos, dependiendo de lo que se haya seleccionado en FIRECLASS Express. Es importante leer los mensajes de la pantalla y seguir las instrucciones, incluyendo la desconexión de los enlaces y la memoria USB, y el reinicio de la central de incendios. Modo de recuperación 1 Utilice este modo si la central de incendios no rearranca correctamente y debe volverse a cargar el firmware para recuperarla. Tenga presente que este modo sobrescribirá el nuevo firmware en la central de incendios. Inserte la memoria USB que contiene la infor- Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Suiza www.fireclass.net 120.515.288_FC-P--I-SPA, doc. versión 1.0, 8. febrero 2016 Sujeto a errores y a modificaciones técnicas. Instrucciones de instalación y montaje Doc. versión 1.0 1/4

Sistema de detección de incendios FIRECLASS Sistema de detección de incendios FIRECLASS mación de arranque creada con FIRECLASS Express. 2 Inserte el enlace X501 (modo de servicio) y el enlace H3. 3 Pulse brevemente el botón de reinicio de la CPU. 4 La central de incendios cargará el firmware de la memoria USB y rearrancará en el modo de arranque. 5 Siga las instrucciones del punto 3 de la sección "Modo de arranque" para cargar una configuración válida. Configuración de transferencia Esta operación requiere una memoria USB. Esta unidad debe prepararse utilizando el menú de transferencia de FIRECLASS Express con los archivos de firmware y configuración apropiados que se van a utilizar para realizar la actualización. Para conocer detalles adicionales sobre la transferencia del firmware, consultar la versión más reciente de la ayuda de FIRECLASS Express. 2/4 Instrucciones de instalación y montaje Doc. versión 1.0 Instrucciones de instalación y montaje Doc. versión 1.0 3/4

Indicazioni per l installazione dei pannelli FIRECLASS Indicazioni per l installazione dei pannelli FIRECLASS Indicazioni per l'installazione dei pannelli FIRECLASS - Scheda di elaborazione centrale Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Svizzera www.fireclass.net 120.515.288_FC-P--I-ITA, doc. versione 1.0, 8. febbraio 2016 Con riserva di modifiche. Il presente opuscolo fornisce istruzioni passo a passo sul modo di aggiornare il pannello e di trasferire la configurazione al pannello. A tal fine, il firmware e la configurazione dell'impianto devono essere disponibili su una dispositivo USB (drive). Creare ciò utilizzando FIRECLASS Express, come descritto nella guida FIRECLASS Express. Aggiornamento Runtime Utilizzare questa modalità per aggiornare un pannello preconfigurato. Questa modalità può essere utilizzata anche per aggiornare un pannello remoto all'interno della rete. È possibile effettuare un solo aggiornamento della configurazione di un pannello di rete. Solo i pannelli remoti possono essere aggiornati utilizzando questa modalità. 1 Inserire il link H3 e il drive USB con il pannello in funzione ed effettuare il login a un livello appropriato. 2 Selezionare l'opzione Menu principale 7 Assistenza 9 - Config. pann. 3 Selezionare il pannello da aggiornare e premere INVIO. 4 Selezionare il progetto a cui appartiene il pannello e premere INVIO. Seguire le istruzioni sullo schermo, pertanto confermare l'aggiornamento, rimuovere il link e riavviare il pannello. Il link H3 deve essere rimosso prima di riavviare il pannello. In caso contrario il pannello potrebbe avviarsi in modalità Startup. Modalità Startup Utilizzare questa modalità per aggiornare l'indirizzo del nodo del pannello e caricare i menu nella lingua locale. Per utilizzare questa modalità occorre aver creato un drive USB con l'info startup per il pannello in FIRECLASS Express. (Per informazioni fare riferimento al file di guida di FIRECLASS Express). 1 Verificare che il link H3 sia inserito. Inserire il drive USB nella scheda. Premere brevemente il pulsante reset sulla CPU. 2 Il pannello si riavvia in modalità Startup. Se il pannello si avvia in modalità normale, seguire le istruzioni per l'"aggiornamento Runtime". 3 Premere il pulsante Password. Immettere USER ID 01 e la PASSWORD utilizzata per creare l'info startup per il drive USB. 4 Selezionare l'opzione 1-Download USB. Nella schermata successiva selezionare il progetto appropriato sul drive. Premere INVIO per selezionarlo. 5 Nella schermata successiva selezionare il pannello appropriato. Questo avvia il download del contenuto dal drive USB nel pannello. Questo comprende il firmware o la configurazione o entrambi, a seconda della selezione effettuata in FIRECLASS Express. È importante osservare i messaggi sul display e seguire i comandi, inclusi quello di rimuovere i link e il drive USB e di riavviare il pannello. Modalità di ripristino 1 Utilizzare questa modalità se il pannello non riesce a riavviarsi e occorre ripristinarlo ricaricando il firmware. Tenere presente che utilizzando questa modalità il nuovo firmware verrà sovrascritto nel pannello. Inserire il drive USB contenente l'info startup creata con FIRECLASS Express. 2 Inserire sia il link X501 (modalità di servizio) sia il link H3. Istruzioni di installazione e montaggio Doc. versione 1.0 1/4

Indicazioni per l installazione dei pannelli FIRECLASS Indicazioni per l installazione dei pannelli FIRECLASS 3 Premere brevemente il pulsante reset sulla CPU. 4 Il pannello carica il firmware dal drive USB nel pannello e si avvia in modalità Startup. 5 Seguire le istruzioni dalla voce 3 nella sezione intitolata "Modalità Startup" per caricare una configurazione valida. Trasferisci configurazione Questa operazione richiede un drive USB. Questo drive deve essere preparato utilizzando il menu Trasferisci all'interno di FIRECLASS Express con il firmware e i file di configurazione appropriati da utilizzare per eseguire l'aggiornamento. Per maggiori dettagli sul trasferimento del firmware, fare riferimento all'ultima versione della guida FIRECLASS Express. 2/4 Istruzioni di installazione e montaggio Doc. versione 1.0 Istruzioni di installazione e montaggio Doc. versione 1.0 3/4